AML EOBD System Operation Summary
Rory O’Curry Aston Martin Lagonda CONFIDENTIAL 1 May 2009
[email protected] AML EOBD Monitors 07 ROC.doc Page 31 of 43
Comprehensive Component Monitor - Automatic Transmission
General
The MIL is illuminated for all emissions related electrical component malfunctions. For malfunctions
attributable to a mechanical component (such as a clutch, gear, band, valve, etc.), some transmissions are
capable of not commanding the mechanically faile d component and providing the remaining maximum
functionality (functionality is reassessed on each power up). In such case a non-MIL Diagnostic Trouble
Code (DTC) will be stored and, if so equipped, a Transmission Control Indicator Light (TCIL) will flash.
For example on the CD4E transmission, if a gear ratio is not properly obtained and verified due to a
mechanical malfunction, the unobtainable gear is no longer commanded for that power up, the DTC is
stored and the TCIL flashes.
Transmission Inputs
Transmission Range Sensor Check Operation:
DTCs P0705, P0708 (open/invalid pattern for digital TRS)
P0707, P0708 (opens/shorts for analog TRS)
Monitor execution continuous
Monitor Sequence none
Monitoring Duration 30 seconds
Typical TRS check entry conditions : Minimum Maximum
Gear selector position each position for up to 30 seconds 480 seconds
Typical TRS malfunction thresholds:
For digital sensor : Invalid pattern from 3 (or 5) digital inputs or 1 analog circuit open for 5 seconds
For analog sensor : Voltage > 4.8 volts or < 0.2 voltage for 5 seconds
Output Shaft Speed Sensor Functional Check Operation:
DTCs P0720
Monitor execution continuous
Monitor Sequence none
Monitoring Duration 30 seconds
Typical OSS functional check entry conditions : Minimum Maximum
Gear selector position drive
Engine rpm (above converter stall speed) OR 3000 rpm
Turbine shaft rpm (if available) OR 1500 rpm
Output shaft rpm 650 rpm
Vehicle speed (if available) 15 mph
Typical OSS functional check malfunction thresholds:
Vehicle is inferred to be moving with positive driving torque and OSS < 100 to 200 rpm for 5 seconds
AML EOBD System Operation Summary
Rory O’Curry Aston Martin Lagonda CONFIDENTIAL 1 May 2009
[email protected] AML EOBD Monitors 07 ROC.doc Page 32 of 43
Turbine Shaft Speed Sensor Functional Check Operation:
DTCs P0715
Monitor execution continuous
Monitor Sequence none
Monitoring Duration 30 seconds
Typical TSS functional check entry conditions: Minimum Maximum
Gear selector position drive
Engine rpm (above converter stall speed) OR 3000 rpm
Turbine shaft rpm (if available) OR 1500 rpm
Output shaft rpm 650 rpm
Vehicle speed (if available) 15 mph
Torque converter lock-up (some applications) 3rd gear only
Typical TSS functional check malfunction thresholds:
Vehicle is inferred to be moving with positiv e driving torque and TSS < 200 rpm for 5 seconds
AML EOBD System Operation Summary
Rory O’Curry Aston Martin Lagonda CONFIDENTIAL 1 May 2009
[email protected] AML EOBD Monitors 07 ROC.doc Page 37 of 43
Glossary of Terms
A/D Analogue to Digital
ASM Auto Shift Manul
BTDC Before Top Dead Centre
CALID CALibration IDentification
CD4E Automatic Transmission for Intermediate size Family saloon.
CID Camshaft Identification.
CKP Crankshaft Position
CMP Camshaft Position
COP Coil on Plug
CPC Camshaft Position Control
CVN Calibration Verification Number
DPFE Delta Pressure Feedback
DTC Diagnostic Trouble Code
ECT Engine Coolant Temperature
EDIS Electronic Distributorless Ignition System
EGR Exhaust Gas Re-circulation.
EOBD European On Bard Diagnostics
EPC Electronic Pressure Control
ETC Electronic Throttle Control
ETM Electronic Throttle Monitor
EVR Electronic Vacuum Regulator
EWMA Exponentially Weighted Moving Average
FMEM Failure Mode and Effects Management
FN Automatic Transmission for Medium size Family Saloon
FWD Front Wheel Drive
HDR High Data Rate
HO2S Heated Oxygen Sensor.
IAC Idle Air Control
IDM Ignition Diagnostic Monitor
IMRC Inlet Manifold Runner Control
IPC Independent Plausibility Checker
KAM Keep Alive Memory
LDR Low Data Rate
LTFT Long Term Fuel Trim
MAF Mass Air Flow
MAP Manifold Absolute Pressure
MIL Malfunction Indicator Lamp
OSS Output Shaft Speed
PCM Powertrain Control Module
PIP Profile Ignition Pickup
RWD Rear Wheel Drive
SAE Society of Automotive Engineers
SAIR Secondary AIR
SCV Swirl Control Valve
STFT Short Term Fuel Trim
TCC Torque Converter Clutch
TCIL Transmission Control Indicator Lamp
TP Throttle Position
TPPC Throttle Plate Position Controller
TRS Transmission Range Sensor
TSS Turbine Shaft Speed
VID Vehicle IDentification
VIN Vehicle Identification No.
VQZ VQuizzer
VMV Vapour Management Valve
Aston Martin V8 Vantage 2009 MY EOBD DocumentationAston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
P0300
to
P0308 Deviations in crankshaft
acceleration processed by
Neural Network Misfire
Monitor software and Catalyst
Temperature model Percentage misfire
required to exceed
Catalyst Damage
Temperature 1000 deg c
(1832 deg F) catalyst
damage threshold, per
engine bank Type A: See RPM/Load
Table FNMISPCT_97 %
Type A:
200 revs
(Continuous)Type A:
Footnote b)
Type A:
Footnote d)
Percentage misfire
required to exceed
emission thresholds Type B> 0.0323*100% Type B:
1000 revs
(Continuous)Type B/C:
Footnote a)
Type B:
Footnote c)
Percentage misfire
required to clear emission
pending code < 0.001 * 100 % Time since engine start,
value based on time and
IAT 0 + FNMISACT sec
(See Transfer Functions)
Time since PCM power up 0 sec
Time for NNMM
computation queue to fill 4 revs from initial crank
(Meets 2 rev start delay
requirement)
Engine coolant temp -7 - 115 deg C ( 20 - 240 degF )
Engine rpm 600 - 7250 rpm
Net engine torque > -81 Nm ( -60 ft lbs)
Engine torque rate of
change > -33.9Nm (-25 ft lbs/sec)
or
< 33.9Nm (25 ft lbs/sec)
Throttle position rate of
change > -30 volts/background
loop or
< 30 * 5/1024
volts/background loop
Engine rpm/load range See RPM/Load Table FNMISOK_97: Monitor
disabled when less than
0.5
Crankshaft position circuit
(PIP) OK (P0320)
Fuel shutoff for rpm or
vehicle speed limiting No fuel cutoff occurring
Fuel level > 0.15 * 100 %
Misfire Detected At
Startup P0316 Misfire detected during first
1000 engine revs since start P0316 is set in addition to
P0300 - P0308 DTC 1000 revs
(Continuous)Footnote a) Footnote c)
AICE chip failure in
PCM P0606 NNMM chip to CPU
communication fault Number of attempts 10
Continuous Footnote a) Footnote c)
Camshaft/crankshaft
synchronization
failure P1336 AICE chip reports inability to
synchronize camshaft and
crankshaft signals
(Replaces P1309) Number of attempts > 255
Continuous Footnote a) Footnote c)
Engine speed >1550rpm
<2275rpm
Engine load >0.075
<0.225
Engine coolant
temperature >68.3degC (155degF)
Transmission in 6th gear
Vehicle speed >30mph
<70mph
Maximum rate of engine
speed change <500rpm/second
In decel fuel cut
ROM checksum error P260F NNP ROM checksum error Checksum from NNP does not equal mainline
strategyNone
Continuous Footnote a) Footnote c)
Cylinder Misfire
DetectedMisfire Monitor
Footnote c)
Unable to learn
crankshaft profile P0315 Unable to learn stable
crankshaft profile Number of attempts > 6 attempts Continuous within
profile learning
entry conditionsFootnote a)
2
Aston Martin V8 Vantage 2009 MY EOBD DocumentationAston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
off/on <0.524 Intake air temp sensor OK (P0112/0113) Continuous during
SAIR operation
on/off <0.671 Engine coolant temp sensor OK (P0117/0118)
Mass Air Flow sensor OK
(P0101 to P010F)
First switch correction <
threshold * corrected SAIR
flow <1+(0.246*Long term
fuel trim)
Time in closed loop
fuelling control (only used
for bank to bank flow
arbitration) >10seconds
off/on <0.524 Intake air temp sensor OK (P0112/0113)
on/off <0.671 Engine coolant temp sensor OK (P0117/0118)
Mass Air Flow sensor OK
(P0101 to P010F)
Closed loop bank1 vs bank2
lambda difference Lambda difference>
threshold AND bank1
lambda > bank2 lambdalambda
difference>0.435
Not in HEGO FMEM
First switch correction <
threshold * corrected SAIR
flow <1+(0.246*Long term
fuel trim)
Time in closed loop
fuelling control (only used
for bank to bank flow
arbitration) >10seconds
off/on <0.524 Intake air temp sensor OK (P0112/0113)
on/off <0.671 Engine coolant temp sensor OK (P0117/0118)
Mass Air Flow sensor OK
(P0101 to P010F)
Closed loop bank1 vs bank2
lambda difference Lambda difference>
threshold AND bank1
lambda < bank2 lambdalambda
difference>0.435
HEGO monitor complete
P2448 (Low
flow Bank1)
P2449
(Low flow
Bank2) SAIR off time before re-
enable (if SAIR is disabled
due to engine conditions)>3seconds
Time in closed loop
fuelling control (only used
for bank to bank flow
arbitration) >10seconds
HEGO monitor complete
SAIR circuit ecu
output high/low P0412 Circuit malfunction
PCM able to determine
failure Time with fault>5
seconds
SAIR circuit relay
high output P2257 Circuit malfunction
PCM able to determine
failure Time with fault>5
seconds
SAIR circuit relay low
output P2258 Circuit malfunction
PCM able to determine
failure Time with fault>5
seconds
Ratio of SAIR flow
difference at SAIR pump
off / on and on/off
transition
Modelled pump flow higher
than measured flow via HFM
Ratio of SAIR flow
difference at SAIR pump
off / on and on/off
transition
Ratio of SAIR flow
difference at SAIR pump
off / on and on/off
transition
>2secondsFootnote c)
Approximately 500
sec during
appropriate FTP74
conditions to
complete HEGO
monitorSecondary Air Monitor
Modelled pump flow higher
than measured flow via HFM Ratio of SAIR flow
difference at SAIR pump
off / on transitionoff/on >1.44
Outlet Hose
Disconnection Footnote l)
Continuous
(circuit checks)
Outlet Hose
Blockage
P0492
(Low flow
Bank2)
P0410
(Inlet hose
disconnection)
Secondary Air
System Insufficient
Flow
Closed loop bank1 lambda
correction at first switch AND
low measured flow via HFM
Closed loop bank2 lambda
correction at first switch AND
low measured flow via HFM
P0491
(Low flow
Bank1)
Time with SAIR active
4
Aston Martin V8 Vantage 2009 MY EOBD DocumentationAston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
P2270
(Bank 1) Inferred exhaust temp 71 - 792 deg C
(160 - 1458 deg F)
P2272
(Bank 2) Downstream heater on
time> 120 sec
Pedal position Part throttle
Engine rpm - for forced
excursion only > 1200 rpm
Inferred exhaust temp - for
forced excursion only < 815 deg C
(< 1500 deg F)
Flex fuel composition not
changing
Upstream sensor(s) tested
P2271
(Bank 1) Inferred exhaust temp 71 - 792 deg C
(160 - 1458 deg F)
P2273
(Bank 2) Downstream heater on
time> 120 sec
Pedal position Part throttle
Engine rpm - for forced
excursion only > 1200 rpm
Inferred exhaust temp - for
forced excursion only < 815 deg C
(< 1500 deg F)
Flex fuel composition not
changing
Upstream sensor(s) tested
Voltage greater than
malfunction threshold > 1.1 volts
Stream 2 HO2S heater on
time > 90 sec
Time with sensor voltage
out of range > 18 sec
Stream 2 HO2S:
Inferred sensor temp > 204 deg C
(> 400 deg F)
HO2S heater OK
(P0141, P0054-bank1)
(P0161, P0060-bank2)
P0135
(HO2S11) Circuit continuity check,
monitor voltage for opens and
shorts Feedback circuit state
matches commanded
output state (Digital
signal)Feedback circuit high
or low
Stream 1 HO2S:
Inferred sensor temp 26.6 - 630.5 deg C
(80 - 1167 deg F)
P0155
(HO2S21) Monitor retries allowed for
malfunction
(Background loops)RETRY_ALLOW
P0053
(HO2S11) Functional check, monitor
min. and max. heater current Heater circuit current < 0.465 amps or
> 3.0 ampsStream 1 HO2S:
Inferred sensor temp 121 - 593 deg C
(250 - 1100 deg F)Once per driving
cycle
Stream 1 HO2S heater on
time > 30 sec
Stream 1 sensor(s) tested
(P0133/P0153 tests
completed)
Stream2 sensor (s) tested
P0136, P0156
P0141
(HO2S12) Circuit continuity check,
monitor voltage for opens and
shorts Feedback circuit state
matches commanded
output state (Digital
signal)Feedback circuit high
or low
Stream 2 HO2S:
Inferred sensor temp 149 - 760 deg C
(300 - 1400 deg F)Continuous
P0161
(HO2S22) Monitor retries allowed for
malfunction
(Background loops)RETRY_ALLOW
P0054
(HO2S12) Functional check, monitor
min. and max. heater current Heater circuit current < 0.22 amps
Stream 2 HO2S:
Inferred sensor temp 121 - 732 deg C
(250 - 1350 deg F)Once per driving
cycle
> 3.0 amps Stream 2 HO2S heater on
time > 30 sec
Stream 1 sensor(s) tested
(P0133/P0153 tests
completed)
Stream2 sensor (s) tested
P0136, P0156
HO2S Heater Circuit
Malfunction
P0060
(HO2S22) Footnote a)
Continuous
Footnote a)
Once per driving
cycle
Once per driving
cycle
Monitor normal signal voltage
envelope; forced A/F
excursion if required for green
catalyst
(Rationality check)
Footnote c)
P0059
(HO2S21)
Stream 2 (CMS)
HO2S Overvoltage
P0138
(Bank 1)
P0158
(Bank 2)Monitor HO2S voltage
Monitor normal signal voltage
envelope; forced A/F
excursion if required for green
catalyst
(Rationality check)
Rear HO2S Circuit
Malfunction
HO2S minimum signal
voltages stuck rich> 0.42 volts
HO2S maximum signal
voltages stuck lean
< 0.48 volts
Footnote c)
Footnote a)
Footnote a)
Footnote c)
Footnote c)
Continuous
8
Aston Martin V8 Vantage 2009 MY EOBD DocumentationAston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
Vehicle speed VSS
(P0500) sensor OK
Throttle position sensor
TPS OK (P0122/0123)
Vehicle speed and TPS in
range VSS<30mph OR
TPS>5.27deg (60cnts)
Battery Voltage 11< Voltage <18
SAIR not commanded >3 seconds
Time with fault >5 seconds
MAF1+MAF2
(0.35*estimate) Vehicle speed VSS
(P0500) sensor OK
MAF1< 0.5*estimate -
max (0.5*30.23g/sec)
OR (0.35*
(0.5*estimate)) Throttle position sensor
TPS OK (P0122/0123)
Vehicle speed and TPS in
range
VSS<30mph OR
TPS>5.27deg (60cnts)
Battery Voltage 11< Voltage <18
SAIR not commanded >3 seconds
Time with fault >5 seconds
Sensor signal voltage < 0.024 volts (0g/sec) Time since last PIP signal (Engine not stalled)< 150 msec
Fault filter routine > 1 sec
Sensor signal voltage > 4.88 volts (293g/sec) Time since last PIP signal (Engine not stalled)< 150 msec
Fault filter routine > 1 sec MAF1+MAF2
(0.35*estimate)Vehicle speed VSS
(P0500) sensor OK
MAF1< 0.5*estimate -
max (0.5*30.23g/sec) Throttle position sensor
TPS OK (P0122/0123)
MAF2< 0.5*estimate -
max (0.5*30.23g/sec)
OR (0.35*
(0.5*estimate)) Vehicle speed and TPS in
range
VSS<30mph OR
TPS>5.27deg (60cnts)
Battery Voltage 11< Voltage <18
SAIR not commanded >3 seconds
Time with fault >5 seconds
Vehicle speed VSS
(P0500) sensor OK
Throttle position sensor
TPS OK (P0122/0123)
Vehicle speed and TPS in
range VSS<30mph OR
TPS>5.27deg (60cnts)
Battery Voltage 11< Voltage <18
SAIR not commanded >3 seconds
Time with fault >5 seconds
MAF1+MAF2
(0.35*estimate) Vehicle speed VSS
(P0500) sensor OK
MAF2< 0.5*estimate -
max (0.5*30.23g/sec)
OR (0.35*
(0.5*estimate)) Throttle position sensor
TPS OK (P0122/0123)
Vehicle speed and TPS in
range
VSS<30mph OR
TPS>5.27deg (60cnts)
Battery Voltage 11< Voltage <18
SAIR not commanded >3 seconds
Time with fault >5 seconds
Sensor signal voltage < 0.024 volts (0g/sec) Time since last PIP signal (Engine not stalled)< 150 msec
Fault filter routine > 1 sec
Sensor signal voltage > 4.88 volts (293g/sec) Time since last PIP signal (Engine not stalled)< 150 msec
Fault filter routine > 1 sec MAF1+MAF2
(0.35*estimate)Vehicle speed VSS
(P0500) sensor OK
MAF1< 0.5*estimate -
max (0.5*30.23g/sec)
OR (0.35*
(0.5*estimate)) Throttle position sensor
TPS OK (P0122/0123)
MAF2< 0.5*estimate -
max (0.5*30.23g/sec)
OR (0.35*
(0.5*estimate)) Vehicle speed and TPS in
range
VSS<30mph OR
TPS>5.27deg (60cnts)
Battery Voltage 11< Voltage <18
SAIR not commanded >3 seconds
Time with fault >5 seconds
P010F
(MAFA/B
Correlation) Rationality Check
MAF codes raised P0100,P0101,P0104,
P010A,P010B,P010ETime with fault
>5 secondsComprehensive Component Monitor
MAF2 voltage < 0.024
(0g/sec) Continuous
P0100 (MAF A
Airpath) Rationality Check - Compares
measured MAF vs modelled
airflow MAF1 vs MAF2 low airflow
Circuit Check
P0103 (High) MAF1< 0.5*estimate -
max (0.5*30.23g/sec)
OR (0.35*
(0.5*estimate))
MAF1+MAF2 not equal to
estimate AND MAF1 vs
MAF2 low airflow
MAF Sensor Input
Circuit Check
P0104
(Backflow) Rationality Check
P0101 (MAF A
Range)
Rationality Check - Compares
measured MAF vs modelled
airflow
P010E
Backflow) Rationality Check
P0102 (Low)
MAF1 voltage < 0.024
(0g/sec)
P010A (MAF B
Airpath)
P010B MAF B
Range) Rationality Check - Compares
measured MAF vs modelled
airflow
Rationality Check - Compares
measured MAF vs modelled
airflow
MAF1+MAF2 not equal to
estimate AND MAF2 vs
MAF1 low airflow
MAF2 vs MAF1 low airflow MAF2< 0.5*estimate -
max (0.5*30.23g/sec)
OR (0.35*
(0.5*estimate)) Footnote a)
MAF1+MAF2 not equal to
estimate AND MAF1 & 2
do not equal estimate.
MAF2 voltage low.
P010C (Low) Circuit Check
Circuit Check
P010D (High) MAF1+MAF2 not equal to
estimate AND MAF1 & 2
do not equal estimate.
MAF1 voltage low.
Footnote c)
9
Aston Martin V8 Vantage 2009 MY EOBD DocumentationAston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
Error between inferred
manifold pressure and
measure manifold
pressure >26.75kPa (7.899"Hg) Engine speed
>600rpm
<8000rpm
Time with fault >1.25 seconds Throttle position sensor
TPS OK (P0122/0123)
Throttle position in range >0cnts (0volts) <1023cnts (4.99volts)
Engine not in transient
load condition <0.39*100
Manifold pressure sensor
OK (P0107/0108)
Sensor signal voltage < 0.04 volts 4.64kPa(1.37"Hg)
Fault filter routine > 5.0 sec
Sensor signal voltage > 4.9 volts 114kPa(33.66"Hg)
Fault filter routine > 5.0 sec
Barometric pressure
below manifold pressure (BP-2.9kPa
[0.859"Hg])
Time with fault >8 secondsManifold pressure sensor
OK (P0106/0107/0108)
Sensor signal voltage <2.3 volts 55.13kPa(16.28"Hg)
Fault filter routine > 5.0 sec
Sensor signal voltage >4.9 volts 107.28kPa (31.68"Hg)
Fault filter routine > 5.0 sec
Sensor input < 0.2 volts 134.3degC
(273.7degF)
Time with sensor input out
of range > 5.0 sec
Sensor input > 4.9 volts
-40.7degC(-41.3F)
Time with sensor input out
of range > 5.0 sec
Air Charge Temperature
stuck + / - 16.6degC
(30degf) from ECT IAT_RAT_THRES soak > 360 min,
ECT >-31.6degC (-25F)Once per drive
cycle
Vehicle speed ROA check VSPD > 12.5 mph time > 5.5 secs once per drive
cycle / <30 mins
Vehicle Speed >12.5 mph
Time above min speed >5 seconds
Change in IAT <2.2degC (4degF)
Number of failure events >2
Sensor signal voltage > 4.9 volts -40.7degC(-
41.25degF)
Fault filter routine > 5.0 sec
Sensor signal voltage < 0.13 volts 150.4degC (302.75degF)
Fault filter routine > 5.0 sec Engine off soak time >360 minutes
IAT sensor OK
(P0112/0113)
Sensor input < 0.2 volts 134.27degC
(273.7degF)
Time with sensor input out
of range > 5.0 sec
Sensor input > 4.9 volts
-40.7degC (-41.3degF)
Time with sensor input out
of range > 5.0 sec
EOT error vs model > +/-38degC (100degF)
Time with fault >30seconds
Sensor input < 0.2 volts 136.8degC
(273.7degF)
Time with sensor input out
of range > 5.0 sec
Sensor input > 4.9 volts
-40.7degC (-41.3degF)
Time with sensor input out
of range > 5.0 sec
Engine coolant temp 110 deg C (> 230 deg F)Continuous time with
engine off prior to start > 360 min
Time with high sensor
signal > 30 sec
ECT at start differs from
IAT at start >28 deg C
(> 50 deg F)
Catalyst, Misfire, Fuel
Rationality check, Engine-Off
timer inoperative ECT at startup cooler than
ECT at previous keyoffError>= 27.8degC (50
degF)ECT at previous keyoff
was hot >32.3degC (90degF)
Soak timer value at startup < 0.5 * 60 sec (Timer indicates that short
soak has occurred)
IAT Sensor Input
P0111IAT Absurdity >FNIA_RAT_OOR
IAT Rationality check
Footnote a) Footnote c)
IAT>Threshold
Footnote c)
Footnote c)
Footnote b)
Once per driving
cycle
Footnote a)
Footnote a)
Footnote a)
Footnote c)
Footnote a)
Footnote a)
>< +/- 26degC
(80degF)
Continuous
Battery Voltage
ECT Sensor Input
Engine-Off (Soak)
Timer Rationality
Test P0606
Once per driving
cycle
Range check
11< Voltage <18
Continuous
P0116 Rationality check (Stuck high) Battery Voltage
P0117 (Low)
P0118 (High) Range check 11< Voltage <18
Battery Voltage 11< Voltage <18 Continuous
P0197 (Low)
P0198 (High) Range check
Range check
EOT Sensor Input
P0196 Rationality
P0112 (Low)
P0113 (High)
Range check
Range check
MATF Sensor Input P009A Rationality Check - error between manifold
temperature and IAT after
long soak Footnote a) Footnote c)
P0106
(Rationality) Rationality Check
Manifold Pressure
Input
P0108 (High) Range check Continuous
Battery Voltage 11< Voltage <18
P0107 (Low) Range check
Barometric Pressure
Input P2228 (Low)
P2229 (High)Range check
Range check
P0069
(Rationality)
Rationality Check
Battery Voltage11< Voltage <18
Battery Voltage 11< Voltage <18 Footnote c)
Footnote a)
Continuous Footnote a) Footnote c)
Footnote c)Footnote c)
Footnote a)
Continuous
Continuous
Manifold temperature - IAT
P0097 (High)
P0098 (Low)
Range check
Range check
10