Body Ventilation system (12.01)
Climate Control (12.00)
May 2007 Workshop Manual 12-1-3
Air Intake Actuator
Inspection
1. Connect the battery positive voltage to Intake Actuator terminal 1 (or 3), and ground to terminal 3 (or 1).
2. Verify that the Air Intake Actuator operates as shown.
Air Mix Actuator
Inspection
1. Connect the battery positive voltage to Air Mix Actuator terminal 6 (or 7), and ground to terminal 7 (or 6). Verify
that the Air Mix Actuator operates as shown.
2. Check that the resistance between terminals 3 and 5, and 1 and 5 matches the Air Mix Actuator operation as
shown in the graph below.
LHD
RHD
If the operation condition is not normal, replace the Air
Intake Actuator.
Terminal (C0149) Air Intake Actuator Operation
13
Ground B+ Fresh > Recirculate
B+ Ground Recirculate > Fresh
If the operation condition is no t normal, replace the Air Mix
Actuator.
Terminal (C2130) Air Intake Actuator Operation
13
B+ Ground Cold - Hot (LHD) Hot - Cold (RHD)
Ground B+ Hot - Cold (LHD) Cold - Hot (RHD)
If the operation condition and resistance are not normal,
replace the Air Mix Actuator.
90°
7°
MAX HOTMAX COLD
3 51
67
3
51
6
7
*
*
MAX HOT MAX COLD
MAX HOT
MAX COLD
351
67
L.H.D.
R.H.D.C213090°
7°
MAX HOTMAX COLD
3 51
67
3
51
6
7
*
*
MAX HOT MAX COLD
MAX HOT
MAX COLD
351
67
L.H.D.
R.H.D.C2130
MAX
HOT
MAX
COLD
MAX
COLD
MAX
HOT
2.6 5.9
BETWEEN 2-5
TERMINALS WIRE
AIR MIX ACTUATOR POSITION BETWEEN 1-5
TERMINALS WIRE
KILOHM
RESISTANCE
MAX
HOT MAX
COLD
MAX
COLD
MAX
HOT
2.6 5.9
BETWEEN 2-5
TERMINALS WIRE
AIR MIX ACTUATOR POSITION BETWEEN 1-5
TERMINALS WIRE
KILOHM
RESISTANCE
Body Ventilation system (12.01)
Climate Control (12.00)12-1-4 Workshop Manual May 2007
Airflow Mode Actuator
Inspection
1. Connect the battery positive voltage to the Airflow Mode Actuator terminal 6 (or 7), and ground to terminal
7 (or 6). Verify that the Airflow Mode Actuator operates
as shown.
2. Verify that the resistance between terminals 1 and 5, and 3 and 5 matches the Airflow Mode Actuator
operation as shown in the graph below.
If the operation condition is no
t normal, replace the Airflow
Mode Actuator.
Terminal Airflow Mode Actuator operation
67
B+ Ground Defroster - Vent
Ground B+ Vent - Defroster
If the operation condition and resistance are not normal,
replace the Airflow Mode Actuator.
90°
32°
351 67 3
51
6
7
**
VENT
DEFROSTERVENT
DEFROSTER C041390°
32°
351 67 3
51
6
7
**
VENT
DEFROSTERVENT
DEFROSTER C0413
1.2
4.7
BETWEEN 3-5
TERMINALS WIRE
AIRFLOW MODE ACTUATOR POSITION BETWEEN 1-5
TERMINALS WIRE
KILOHMRESISTANCE
VENT DEFROSTER VENT DEFROSTER1.24.7
BETWEEN 3-5
TERMINALS WIRE
AIRFLOW MODE ACTUATOR POSITION BETWEEN 1-5
TERMINALS WIRE
KILOHMRESISTANCE
VENT DEFROSTER VENT DEFROSTER