Page 923 of 947

Aston Martin V12 Family
2009 MY V12 Family EOBDincl. V12 Vantage
Aston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
Sensor input stuck
midrange 123 +/- 34 kPa
(17.9 +/- 5.0 psig)
Large control error 34 kPa (> 5.0 psig)
Sensor value not moving 5.5 kPa/second (< 0.8 psig/second)
Time with sensor input out
of range > 8.0 sec
(Demand - sensed) error
too large > 172 kPa
(25.0 psig)Demand pressure within
limits < 448 kPa or > 241 kPa
(< 65.0 psig or > 35.0
psig)
Time with sensor input out
of range > 8.0 sec
Fuel level above minimum
level > 0.15 * 100 %
Sensor input < 0.05 volts
(<0kPa)
Time with sensor input out
of range > 8.0 sec
Sensor input > 4.88 volts
(>517kPa)
Time with sensor input out
of range > 8.0 sec
P1233 Fuel pump driver module disabled or off line Time with failure > 3.0 seconds
P1235 Fuel pump control out of range Time with failure > 3.0 seconds
P0201 Circuit continuity check, open or shorted Smart power driver status 1 = malfunction Battery voltage
> 11.0 volts
P0202 Time with circuit
malfunction > 3.5 sec
Engine coolant temp < 116 deg C (< 240 deg F)
P0203 Intake air temp66 deg C (< 150 deg F)
P0204
P0205
P0206
P0320 Engine rpm (Used to
determine crank mode) > FN384A rpm
(See Function)None
Intermittent/Noisy CKP signal
check Number of CKP edges
incorrect, missing tooth in None
Increment fault counter by
25 on each event. Set
P0322 Engine speed input circuit no signal Compares engine rpm on
one bank to engine rpm o
nNone
Increment fault counter by
4 on each event. Set
Camshaft Position
Input P0340 Rationality check
Ratio of PIP events to CID
events n to 1 (To pass test) None
N/A Footnote c)
Footnote c)
Fuel Rail Pressure
Input P0190
P0191
P0192 (Low)
P0193 (High)Range check
Range/Performance check
Fuel Pump Continuous
Circuit malfunction N/A
Continuous Footnote a) Footnote c)
None
None
N/A Footnote a)
Fuel Injectors Footnote c)
Ignition System- CKP
Circuit Malfunction Continuous Footnote a) Footnote c)
Continuous Footnote a)
12
Page 924 of 947

Aston Martin V12 Family
2009 MY V12 Family EOBDincl. V12 Vantage
Aston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ation
P0351(Coil A) Ratio of PIP events to
spark events seen 1 to 1 (To pass test) Battery voltage
> 11.0 volts or < 18.0 volts Continuous Footnote a) Footnote c)
P0352(Coil B) PCM able to determine
coil Yes
P0353(Coil C)
P0354(Coil D)
P0355(Coil E)
P0356(Coil F) Functional check -
overspeed error Difference between actual
and desired rpm> -200 rpm
Engine coolant temp -7 deg C (> 20 deg F)
Time since engine start > 100 sec
Time with solenoid at limit > 15 sec Fuel controlClosed loop
Idle state At idle
Difference between actual
and desired rpm > 100 rpm
Engine coolant temp -7 deg C (> 20 deg F)
Closed loop MAF
correction > 4.5 g/sec
(> 0.6 lbs/min)Time since engine start > 100 sec
Time with solenoid at limit > 10 sec Fuel controlClosed loop
Idle state At idle
Vehicle Speed
Sensor P0500 Functional check - operational Evaluates CAN source VS > 3 mph
> 4 secondsVehicle moving
Commanded dutycycle on
or full-off >=0.135 * 100 % or =
0%None
N/A Continuous Footnote a) Footnote e)
Signal circuit voltage Refer to Appendix for threshold calculation
Time with circuit
malfunction > 5 sec
P0460 (Range
Check) Sensor input
<= 7 or >= 254 A/D
counts w/in a range of
256 A/D counts
P0462 (Low) < 7 A/D counts
P0463 (High) > 254 A/D counts
Time with sensor out of
range > 30 sec N/A
Continuous Footnote a) Footnote j)
Fuel Level Input Out
Of Range Sensor range check
None
Vapor Management
Valve Circuit
Malfunction
P0443 Circuit continuity test, open or
shorted Footnote a) Footnote c)
IAC Solenoid
Underspeed Error P0506 Functional check -
underspeed error Continuous
IAC Solenoid
Overspeed Error
P0507
Continuous Footnote a) Footnote c)
Ignition System-
Ignition Coil Primary
Circuit Malfunction
Rationality check
13
Page 926 of 947

Aston Martin V12 Family
2009 MY V12 Family EOBDincl. V12 Vantage
Aston Martin/Ford Confidential
Component/ System Fault Code Monitor Strategy
Description Malfunction Criteria Threshold Parameter Secondary Parameters Entry Parameters Time Required DTC
StorageMIL Illumin-
ationTPPC chip failure in
PCM P0606 TPPC chip to CPU
communication fault Number of attempts > 1
Continuous Footnote a) Footnote c)
Engine rpm > 1000 rpmEngine coolant temp > 15 deg C (> 60 deg F) Continuous Footnote a) Footnote c)
Sensor signal voltage < 0.73 volts or > 3.0 volts
Engine load > 0.7 * 100% or < 0.2
* 100%
Time with sensor out of
range > 5.0 sec
Time with low throttle
voltage at TPPC or PCM >= 0.254 seconds
Sensor signal voltage < 0.2 volts
Time with high throttle
voltage at TPPC or PCM >= 0.254 seconds
Sensor signal voltage > 4.87 volts
Time with low throttle
voltage at TPPC or PCM >= 0.254 seconds
Sensor signal voltage < 0.08 volts
Time with high throttle
voltage at TPPC or PCM >= 0.254 seconds
Sensor signal voltage > 4.80 volts
Time with correlation
failure from the TPPC or
PCM or Equizzer >= 240 sec
Magnitude of the
difference of the relative
readings of the sensor
signal voltage > 0.25 volts
(10.25degrees)
P2104 ETC FMEM – forced idle Two or three pedal sensors failed, throttle
plate stuck>= 100 to 400 msec None
N/AContinuous Footnote a) Footnote c)
P2105 ETC FMEM – forced engine shutdown Equizzer detected fault >= 16 to 960 msec None
N/AContinuous Footnote a) Footnote c)
P2106 ETC FMEM – pedal-follower mode Sensor fault: MAF, one
TP, CKP, TSS, OSS,
stuck throttle, throttle
actuator circuit fault>= 16 to 960 msec None
N/AContinuous Footnote a) Footnote c)
P2110 ETC FMEM – default throttle angle Two TPs failed; TPPC
detected fault>= 600 to 800 msec None
N/AContinuous Footnote a) Footnote c)
Throttle Actuator
Control SystemElectronic Throttle ControlTP Sensor A/B
Correlation
P2135 Rationality check None N/A Continuous Footnote a) Footnote c) Footnote c)
TP Sensor 'B' Input
Out Of Range P0222 (Low)
P0223 (High)Range check None N/A Continuous Footnote a) Footnote c) None N/A Continuous Footnote a)
TP Sensor 'A' Input
Out Of Range P0122 (Low)
P0123 (High)Range check
TP Sensor
Inconsistent With
MAF Sensor
P0068 Rationality check vs. MAF
input
15