62B-8
MR-413-X44-62B000$092_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - List and location of components
List and location of components
System (cold loop, hot loop and components)
1Heating and air conditioning unit
2Heater matrix
3Expansion valve and evaporator
4Coolant circuit
5Cold loop
6Condenser and radiator
7Compressor
●COLD LOOP COMPONENTS
–Compressor: This is located at the bottom on the left-hand side, next to the radiator in the engine compartment.
–Condenser: This is located between the radiator and the cooling fan assembly.
–Dehydrator reservoir: This is located on the left-hand side of the condenser outlet.
–Heating and air conditioning unit: This is located under the dashboard.
–Thermostatic expansion valve: This is located to the left of the heating and air conditioning unit on the
bulkhead.
–Evaporator: This is located to the right of the thermostatic expansion valve in the heating and air conditioning
unit.
–High pressure pipe: This pipe connects the compressor, condenser, dehydrator reservoir, and expansion valve
inlet in series (it is located in the engine compartment on the left-hand side).
–Low pressure pipe: This pipe connects the expansion valve, buffering capacity, evaporator, and compressor
inlet in series (it is located in the engine compartment on the left-hand side).
Vdiag No.: 44
MR-413-X44-62B000$092_eng.mif
62B-10
MR-413-X44-62B000$138_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Role of components
●COLD LOOP COMPONENTS
System assembly
1Heating and air conditioning unit
2Heater matrix
3Expansion valve and evaporator
4Coolant circuit
5Cold loop
6Condenser and radiator
7Compressor
–Compressor:
The compressor is not activated when the exterior temperature is less than 0˚; it is used to compress the refrigerant
fluid into gas. The pressure can reach up to 28 bar.
Air conditioning compressor
Vdiag No.: 44
MR-413-X44-62B000$138_eng.mif
62B-19
MR-413-X44-62B000$230_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Function62B
Vehicle
multiplex
network
Summary diagram of components controlled or managed by the UCH:
Summary diagram of components controlled or managed by the injection computer Rear screen de-icing and
rear-view mirror de-icer
(depending on version)External
temperature sensor
(depending on
version)
Actuator control Sensor management
UCH
Air conditioning request
managementHeated rear screen control
management
Relay No. 1 for
the Passenger
Compartment
Heating
ResistorsRelay No. 2 for
the Passenger
Compartment
Heating
ResistorsAir conditioning
compressorEngine cooling
fan assemblyEngine
coolant
temperature
sensorRefrigerant
fluid
pressure
sensor
Actuator control Sensor management
Engine injection computer
Management of the cold loop (refrigerant pressure,
engine cooling fan activation request,
compressor activation authorisation, etc.)
Key:
Wire connections =
Multiplex connections =
62B-32
MR-413-X44-62B000$460_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Conformity check
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), AIR
CONDITIONING OFF (air conditioning compressor not activated).
Note:
–Read the parameters when the vehicle is cold (in the morning) to check the
conformity of the temperature parameters (without thermometer). The two
temperatures should be practically the same (as should the coolant temperature
given by the injection system).
–The invalid values given in this check correspond to the value sent by the diagnostic
tool (substitute value) when the sensor in question is faulty. A sensor fault can be
detected when these invalid values are displayed (this is an important point for
sensors on which fault finding cannot be performed, e.g. exterior temperature
sensor).
Delayed illumination of the exterior temperature sensor LCD indicates that an invalid
value has been received concerning the exterior temperature sensor.
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
Passenger
compartment
blowerET141:Passenger
compartment
blowerRUNNING
or
STOPPED
After a user requestIn the event of a fault, refer to the
interpretation of this status.
PR019:Passenger
compartment
fan PWM settingSpeed 0 = 0 %
Speed 8 = 100 %
Note:
The PWM signal is a
modulated control
voltage used to control
the air conditioning
blower power module.If there is a fault or for more
information (to find the
intermediate speed
percentages), refer to the
interpretation of this
parameter.
Note:
If the parameter varies correctly,
but the passenger compartment
blower unit does not operate:
consult ALP 5 "Air flow fault"
Air flapsPR012:Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C)
to 100 % (“Maximum
hot” position: 27 ˚C).In the event of a fault, see the
interpretation of this
parameter.
ET062:Recirculation
flap positionOPEN if the flap is in the
external air position.
CLOSED if the flap is in
the recirculation
position.In the event of a fault, refer to the
interpretation of this status.
PR011:Distribution flap
positionFrom 0 % (Air vent
position)
to 100 % (De-icing
position)In the event of a fault, see the
interpretation of this
parameter.
CLIM_V44_CCONF
Vdiag No.: 44
MR-413-X44-62B000$460_eng.mif
62B-35
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
HEATING SUB-FUNCTION
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), CLIMATE
CONTROL OFF (air conditioning compressor not engaged).
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
Heated rear screenET086:Heated rear
screen: manual
modeINACTIVE In the event of a fault, refer to the
interpretation of this status.
ET085:Heated rear
screen:
automatic modeINACTIVE In the event of a fault, refer to the
interpretation of this status.
Passenger
compartment
ventilatorET141:Passenger
compartment
ventilatorRUNNING
or
STOPPED
After a user requestIn the event of a fault, refer to the
interpretation of this status.
Air mixing motorPR012:Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C)
to 100 % (“Maximum
hot” position: 27 ˚C).In the event of a fault, see the
interpretation of this
parameter.
HeatingPR045:Current heating
resistor power0 WIn the event of a fault, see the
interpretation of this
parameter.
TemperaturePR001:Interior
temperatureX = interior
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see the
interpretation of this
parameter.
PR002:External
temperatureX = exterior
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, consult the
interpretation of this
parameter.
Note:
This parameter is displayed via
the climate control computer but
is generated by the UCH.
PR004:Coolant
temperatureX = engine coolant
temperature in ˚CIn the event of a fault, see the
interpretation of this
parameter.
62B-37
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning
compressor activated).
Note:
–Read the parameters when the vehicle is cold (in the morning) to check the
conformity of the temperature parameters (without thermometer). The two
temperatures should be practically the same (as should the coolant temperature
given by the injection system).
–The invalid values given in this check correspond to the value sent by the diagnostic
tool (substitute value) when the sensor in question is faulty. A sensor fault can be
detected when these invalid values are displayed (this is an important point for
sensors on which fault finding cannot be performed, e.g. exterior temperature
sensor).
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
Passenger
compartment
blowerPR019: Passenger
compartment
fan PWM settingSpeed 0 = 0 %
Speed 8 = 100 %
Note:
The PWM signal is a
modulated control
voltage used to control
the air conditioning
blower power module.If there is a fault or for more
information (to find the
intermediate speed
percentages), refer to the
interpretation of this
parameter.
Note:
If the parameter varies correctly,
but the passenger compartment
blower unit is not working: refer to
fault finding chart no. 5.
ET141: Passenger
compartment
blowerRUNNING
or
STOPPED
After a user request.In the event of a fault, refer to the
interpretation of this status.
Air flapsPR012: Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C)
to 100 % (“Maximum
hot” position: 27 ˚C).In the event of a fault, see the
interpretation of this
parameter.
ET062: Recirculation
flap positionOPEN if the flap is in the
external air position.
CLOSED if the flap is in
the recirculation
position.In the event of a fault, refer to the
interpretation of this status.
PR011: Distribution flap
positionFrom 0 % (Air vent
position)
to 100 % (De-icing
position).In the event of a fault, refer to the
interpretation of this status.
62B-40
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
HEATING SUB-FUNCTION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning
compressor activated).
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Heated rear
screenET086: Heated rear
screen: manual
modeACTIVE: De-icing
request using the control
button.
INACTIVE otherwise.In the event of a fault, refer
to the interpretation of this
status.
ET085:Heated rear
screen:
automatic modeACTIVE: De-icing
request using the control
button. (“see clear”
function)
INACTIVE otherwise.In the event of a fault, refer
to the interpretation of this
status.
2Passenger
compartment
blowerET141:Passenger
compartment
blowerRUNNINGIn the event of a fault, refer
to the interpretation of this
status.
3Air mixing
motorPR012:Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C
to 100 % = “Maximum
hot” position: 27 ˚C).In the event of a fault, see
the interpretation of this
parameter.
4HeatingPR045:Current heating
resistor power0 < X < 900 WIn the event of a fault, see
the interpretation of this
parameter.
5TemperaturePR001:Interior
temperatureX = interior
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see
the interpretation of this
parameter.
PR002: External
temperatureX = exterior
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, see
the interpretation of this
parameter
Note:
This parameter is displayed
via the climate control
computer but is generated
by the UCH.
PR004:Coolant
temperatureX = engine coolant
temperature in ˚C.In the event of a fault, see
the interpretation of this
parameter.
62B-51
MR-413-X44-62B000$598_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Parameter summary table
Tool parameter Diagnostic tool title
PR001Interior temperature
PR002External temperature
PR004Coolant temperature
PR011Distribution flap position
PR012Mixing flap position
PR019Passenger compartment PWM* setting
PR045Current heating* resistor power
PR092Battery voltage
PR122Night lighting level
Vdiag No.: 44