62B
CLIMATE CONTROL
Fault finding - Interpretation of faults
DF001
PRESENT
OR
STOREDCOMPUTER
1. DEF: Internal electronic fault
NOTESConditions for running fault finding on a present or stored fault:
Apply this fault finding procedure if the fault reappears as present or stored after the
ignition is switched of f and on again.
Switch off the ignition and wait for the immobiliser warning light (Power-latch) to come one,
–Switch on the ignition again.
–Start the engine and switch on the air conditioning.
If the fault recurs, contact the Techline.
If the fault does not reappear: leave the climate control switched on and select various ventilation and air
distribution settings to check that the system is operating correctly.
–Check that no fault is displayed.
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
If the computer was replaced (at the request of the Techline), reconfigure the
computer (see Configurations and programming).
Deal with any other faults.
CLIM_V44_DF001
Vdiag No.: 44
MR-413-X44-62B000$414_eng.mif
Page 32 of 99

62B-32
MR-413-X44-62B000$460_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Conformity check
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped with ignition on (12 V APC), AIR
CONDITIONING OFF (air conditioning compressor not activated).
Note:
–Read the parameters when the vehicle is cold (in the morning) to check the
conformity of the temperature parameters (without thermometer). The two
temperatures should be practically the same (as should the coolant temperature
given by the injection system).
–The invalid values given in this check correspond to the value sent by the diagnostic
tool (substitute value) when the sensor in question is faulty. A sensor fault can be
detected when these invalid values are displayed (this is an important point for
sensors on which fault finding cannot be performed, e.g. exterior temperature
sensor).
Delayed illumination of the exterior temperature sensor LCD indicates that an invalid
value has been received concerning the exterior temperature sensor.
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
Passenger
compartment
blowerET141:Passenger
compartment
blowerRUNNING
or
STOPPED
After a user requestIn the event of a fault, refer to the
interpretation of this status.
PR019:Passenger
compartment
fan PWM settingSpeed 0 = 0 %
Speed 8 = 100 %
Note:
The PWM signal is a
modulated control
voltage used to control
the air conditioning
blower power module.If there is a fault or for more
information (to find the
intermediate speed
percentages), refer to the
interpretation of this
parameter.
Note:
If the parameter varies correctly,
but the passenger compartment
blower unit does not operate:
consult ALP 5 "Air flow fault"
Air flapsPR012:Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C)
to 100 % (“Maximum
hot” position: 27 ˚C).In the event of a fault, see the
interpretation of this
parameter.
ET062:Recirculation
flap positionOPEN if the flap is in the
external air position.
CLOSED if the flap is in
the recirculation
position.In the event of a fault, refer to the
interpretation of this status.
PR011:Distribution flap
positionFrom 0 % (Air vent
position)
to 100 % (De-icing
position)In the event of a fault, see the
interpretation of this
parameter.
CLIM_V44_CCONF
Vdiag No.: 44
MR-413-X44-62B000$460_eng.mif
Page 37 of 99

62B-37
MR-413-X44-62B000$460_eng.mif
V1
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning
compressor activated).
Note:
–Read the parameters when the vehicle is cold (in the morning) to check the
conformity of the temperature parameters (without thermometer). The two
temperatures should be practically the same (as should the coolant temperature
given by the injection system).
–The invalid values given in this check correspond to the value sent by the diagnostic
tool (substitute value) when the sensor in question is faulty. A sensor fault can be
detected when these invalid values are displayed (this is an important point for
sensors on which fault finding cannot be performed, e.g. exterior temperature
sensor).
FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
Passenger
compartment
blowerPR019: Passenger
compartment
fan PWM settingSpeed 0 = 0 %
Speed 8 = 100 %
Note:
The PWM signal is a
modulated control
voltage used to control
the air conditioning
blower power module.If there is a fault or for more
information (to find the
intermediate speed
percentages), refer to the
interpretation of this
parameter.
Note:
If the parameter varies correctly,
but the passenger compartment
blower unit is not working: refer to
fault finding chart no. 5.
ET141: Passenger
compartment
blowerRUNNING
or
STOPPED
After a user request.In the event of a fault, refer to the
interpretation of this status.
Air flapsPR012: Mixing flap
positionFrom 0 % (“Maximum
cold” position: 15 ˚C)
to 100 % (“Maximum
hot” position: 27 ˚C).In the event of a fault, see the
interpretation of this
parameter.
ET062: Recirculation
flap positionOPEN if the flap is in the
external air position.
CLOSED if the flap is in
the recirculation
position.In the event of a fault, refer to the
interpretation of this status.
PR011: Distribution flap
positionFrom 0 % (Air vent
position)
to 100 % (De-icing
position).In the event of a fault, refer to the
interpretation of this status.
Page 57 of 99
62B-57
MR-413-X44-62B000$644_eng.mif
V1
CLIMATE CONTROL
Fault finding - Interpretation of parameters
Vdiag No.: 44
62B
Controlled values with the engine stationary and engine running with heating and ventilation in manual mode
(tolerance ± 5 %).
If the values given above are correct but the passenger compartment blower does not work,
see ALP 5 No passenger compartment ventilation. PR019
PASSENGER COMPARTMENT PWM* SETTING
NOTESThe values listed below are examples only.
Passenger compartment
blower speed settingSPEED
0SPEED
1SPEED
2SPEED
3SPEED
0SPEED
5SPEED
6SPEED
7SPEED
8
PR019 Passenger
compartment blower unit
PWM setpoint.0 % 20 % 25 % 33 % 43 % 50 % 60 % 77 % 100 %
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_PR019