17B-101V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF089
PRESENT
OR
STOREDINLET MANIFOLD PRESSURE SENSOR CIRCUIT
1.DEF: Signal incoherent
2.DEF: Abnormal voltage
3.DEF: EOBD
NOTESConditions for applying the fault finding procedure to stored faults:
1.DEF: The fault is declared present with the engine running after a few seconds.
2.DEF: The fault is declared present with the engine running.
Special notes:
Minimum idle speed of 900 rpm.
The injection goes into defect mode 5: the ESP and the cruise control - speed limiter
are deactivated. The vehicle stalls under idle speed. The level 1 and OBD fault
warning lights are lit.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check the condition of the manifold pressure sensor and its connections (component code 147).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the voltage of the manifold pressure sensor between connections 3FG and 3F.
If the voltage of the manifold pressure sensor is not between:
●4.75 V < X < 5.25 V with the engine stopped, replace the sensor.
Check the condition of the engine management computer connector (component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the universal bornier to check the insulation and continuity of the following connections:
●3LG between components 147 and 120,
●3F between components 147 and 120,
●3CK between components 147 and 120.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
SIM32_V44_DF089/SIM32_V4C_DF089/SIM32_V50_DF089/SIM32_V54_DF089
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
17B-107V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF095
PRESENT
OR
STOREDTHROTTLE POTENTIOMETER CIRCUIT GANG 1CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistency between throttle gang 1 and gang 2
2.DEF: EOBD
WARNING:
Never drive the vehicle without having confirmed that no faults involving the throttle valve are present.
NOTESPriorities when dealing with a number of faults:
Deal first with fault DF012 Sensor supply voltage no. 2 whether it is present or
stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on.
Special notes:
The level 1 fault warning light is lit, the injection goes into defect mode 4, causing a
maximum speed limitation of 66 mph (110 km/h) and a loss of power when accelerating
(impression of having a "soft" pedal).
2.DEF: The throttle valve goes into defect mode 1 and 2, causing a limitation of vehicle
and engine speed. The ESP and the cruise control - speed limiter are deactivated.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III, or
MODUS.
Check the condition of the engine management computer connector (component code 120) and of the throttle
valve connector (component code 1076).
Check that the throttle valve rotates correctly (no resistance).
Check the condition.
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
SIM32_V44_DF095/SIM32_V4C_DF095/SIM32_V50_DF095/SIM32_V54_DF095
AFTER REPAIRIf the throttle valve has been replaced, program the throttle stops, RZ005 Programming.
Follow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
17B-109V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF096
PRESENT
OR
STOREDTHROTTLE POSITION POTENTIOMETER CIRCUIT GANG 2CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: EOBD
WARNING:
Never drive the vehicle without having confirmed that no faults involving the throttle valve are present.
NOTESPriorities when dealing with a number of faults:
Deal first with fault DF012 Sensor supply voltage no. 2 whether it is present or
stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present, with the ignition on.
Special notes:
The level 1 fault warning light is lit, the injection goes into defect mode 4, causing a
maximum speed limitation of 66 mph (110 km/h) and a loss of power when accelerating
(impression of having a "soft" pedal).
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III, or
MODUS.
Check the condition of the connector of the engine management computer (component code 120) and of the
throttle valve (component code 1076).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check that the throttle valve rotates correctly (no resistance).
SIM32_V44_DF096/SIM32_V4C_DF096/SIM32_V50_DF096/SIM32_V54_DF096
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
17B-116V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF109
PRESENT
OR
STOREDLOW FUEL LEVEL MISFIRING
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Firstly, deal with the following faults:
–DF085 Fuel pump relay control circuit,
–DF026 Cylinder 1 injector circuit
–DF027 Cylinder 2 injector circuit, DF028 Cylinder 3 injector circuit,
–DF029 Cylinder 4 injector circuit,
–DF059 Misfiring on cylinder 1,
–DF060 Misfiring on cylinder 2,
–DF061 Misfiring on cylinder 3,
–DF062 Misfiring on cylinder 4,
–DF436 Combustion misfiring detection,
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present when the engine is running.
Special notes:
1.DEF: As soon as the fault is detected, the injection is cut for the faulty cylinder(s) to
limit the rise in temperature inside the catalytic converter. The OBD warning light
flashes for as long as the fault is present.
2.DEF: The OBD warning light is continuously lit.
Check:
–the level of fuel in the tank,
–the conformity and the grade of the fuel, apply test 1 Petrol conformity check,
–the fuel filter,
–the fuel pump,
–the fuel lines,
–the fuel pressure.
If there is no present or stored misfiring fault, the misfiring was caused by the low fuel level.
SIM32_V44_DF109/SIM32_V4C_DF109/SIM32_V50_DF109/SIM32_V54_DF109
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
17B-120V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF127
PRESENT
OR
STOREDBRAKE SWITCH 1 CIRCUIT
1.DEF: No signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is present after the ignition has been switched on and the brake pedal
has been depressed.
Special notes:
The fault appears after a fault on one of the two brake switch contacts.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check:
–the consistency of statuses ET704 Brake switch no. 1 and ET705 Brake switch no. 2 becoming ACTIVE -
INACTIVE when the brake pedal is depressed,
–the condition and cleanliness of the brake lights switch, component code 160.
Disconnect the battery and the injection computer, check the condition and cleanliness of the injection computer
connections, component code 120.
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation and continuity of the following connection:
●5A between components 120 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, carry out a fault finding procedure on the Anti-lock Braking System (see 38C, Anti-lock
Braking System).
If the fault is still present, contact the Techline.
SIM32_V44_DF127/SIM32_V4C_DF127/SIM32_V50_DF127/SIM32_V54_DF127
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
17B-121V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C
and 54
DF128
PRESENT
OR
STOREDBRAKE SWITCH 2 CIRCUIT
1.DEF: No signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is present after the ignition has been switched on and the brake pedal has
been depressed.
Special notes:
The fault appears after a fault on one of the two brake switch contacts.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check:
–the consistency of statuses ET704 Brake switch no. 1 and ET705 Brake switch no. 2 becoming ACTIVE -
INACTIVE when the brake pedal is depressed,
–the condition and cleanliness of the brake lights switch, component code 160.
Disconnect the battery and the injection computer, check the condition and cleanliness of the injection computer
connections, component code 120.
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation and continuity of the following connection:
●5A between components 120 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, carry out a fault finding procedure on the Anti-lock Braking System (see 38C, Anti-lock
Braking System).
If the fault is still present, contact the Techline.
SIM32_V44_DF128/SIM32_V4C_DF128/SIM32_V54_DF128
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
17B-126V7 MR-413-X44-17B000$133.mif
17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF196
PRESENT
OR
STOREDPEDAL SENSOR CIRCUIT GANG 1CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistency between pedal gang 1 and gang 2
2.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Deal first with fault DF012 Sensor feed voltage no. 2 if it is present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the accelerator pedal is depressed several times.
Special notes:
The level 1 fault warning light is lit, the throttle valve goes into defect mode 4, causing
a maximum speed limitation of 66 mph (110 km/h) and a loss of power when
accelerating (impression of having a "soft" pedal).
CO.0: The vehicle has a tendency to decelerate.
CC.1: The vehicle has a tendency to accelerate.
2.DEF: The throttle valve goes into defect mode 3, causing a driver's request loss
(no response from the accelerator pedal).
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check that the pedal mechanism has not seized.
Repair if necessary.
Check the condition of the pedal potentiometer connector (component code 921) and the engine management
computer connector (component code 120).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
SIM32_V44_DF196/SIM32_V4C_DF196/SIM32_V50_DF196/SIM32_V54_DF196
PETROL INJECTION
Fault finding – Interpretation of faults
AFTER REPAIRFollow the instructions to confirm repair:
–If the fault is present, continue to deal with the fault.
–If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
17B-128V7 MR-413-X44-17B000$133.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF198
PRESENT
OR
STOREDPEDAL SENSOR CIRCUIT GANG 2
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Deal first with fault DF096 Sensor feed voltage no. 1 whether it is present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the accelerator pedal is depressed several times.
Special notes:
The vehicle is liable to hesitate. The level 1 fault warning light is lit, the throttle valve
goes into defect mode 4, causing a maximum speed limitation of 66 mph (110 km/h)
and a loss of power when accelerating (impression of having a "soft" pedal).
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check that the pedal mechanism has not seized.
Repair if necessary.
Check the condition of the pedal potentiometer connector (component code 921) and the engine management
computer connector (component code 120).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
SIM32_V44_DF198/SIM32_V4C_DF198/SIM32_V50_DF198/SIM32_V54_DF198
AFTER REPAIRFollow the instructions to confirm repair:
–If the fault is present, continue to deal with the fault.
–If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.