Page 109 of 348

17B-109V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF096
PRESENT
OR
STOREDTHROTTLE POSITION POTENTIOMETER CIRCUIT GANG 2CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: EOBD
WARNING:
Never drive the vehicle without having confirmed that no faults involving the throttle valve are present.
NOTESPriorities when dealing with a number of faults:
Deal first with fault DF012 Sensor supply voltage no. 2 whether it is present or
stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present, with the ignition on.
Special notes:
The level 1 fault warning light is lit, the injection goes into defect mode 4, causing a
maximum speed limitation of 66 mph (110 km/h) and a loss of power when accelerating
(impression of having a "soft" pedal).
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III, or
MODUS.
Check the condition of the connector of the engine management computer (component code 120) and of the
throttle valve (component code 1076).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check that the throttle valve rotates correctly (no resistance).
SIM32_V44_DF096/SIM32_V4C_DF096/SIM32_V50_DF096/SIM32_V54_DF096
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 111 of 348
17B-111V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF099
PRESENT
OR
STOREDAUTOMATIC OR SEQUENTIAL GEARBOX CONNECTION VIA
THE
MULTIPLEX NETWORK
1.DEF: Signal incoherent
2.DEF: Multiplex line connection fault
3.DEF: Gear ratio
4.DEF: EOBD
5.DEF: Converter status
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine running.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, run fault finding on the Sequential gearbox (see 21B, Sequential gearbox).
SIM32_V44_DF099/SIM32_V4C_DF099/SIM32_V50_DF099/SIM32_V54_DF099
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 112 of 348
17B-112V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF100
PRESENT
OR
STOREDINSTRUMENT PANEL MULTIPLEX CONNECTION
1.DEF: Multiplex line connection fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine running.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, run fault finding on the Instrument panel system (see 83A, Instrument panel).
SIM32_V44_DF100/SIM32_V4C_DF100/SIM32_V50_DF100/SIM32_V54_DF100
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 113 of 348
17B-113V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
* ESP: Electronic Stability Program
DF101
PRESENT
OR
STOREDELECTRONIC STABILITY PROGRAM MULTIPLEX CONNECTION
1.DEF: Multiplex line connection fault
NOTESConditions for applying the fault finding procedure to stored faults
The fault is declared present when the ignition is switched on.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, run fault finding on the ESP* system (see 38C, Anti-lock braking system).
SIM32_V44_DF101/SIM32_V4C_DF101/SIM32_V50_DF101/SIM32_V54_DF101
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 114 of 348

17B-114V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF102
PRESENT
OR
STOREDALTERNATOR POWER SIGNAL AVAILABLE
1.DEF: Multiplex line connection fault
NOTESConditions for applying the fault finding procedure to stored faults
The fault is declared present when the ignition is switched on or with the engine running.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, check the insulation and continuity of the following connections:
For NEW TWINGO or E33:
●AP29 between components 120 and 1016,
●2N between components 645 and 103,
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
For Clio III and MODUS:
●AP between components 120 and 1337,
●2N between components 1337 and 103.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
SIM32_V44_DF102/SIM32_V4C_DF102/SIM32_V50_DF102/SIM32_V54_DF102
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 117 of 348

17B-117V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C
and 54
DF119
PRESENT
OR
STOREDCAMSHAFT SENSOR SIGNAL1.DEF: Camshaft tooth event
2.DEF: Tooth lost
3.DEF: Measurement of the offset outside permitted range of values
4.DEF: EOBD
5.DEF: Programming the stops
6.DEF: Programming the initial stops
NOTESPriorities when dealing with a number of faults:
Deal first with fault DF084 Actuator relay control circuit or DF046 Battery voltage
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present when the engine is running.
Special notes:
Engine operation without camshaft dephaser: deterioration in fuel consumption
performance.
Use Wiring Diagram Technical Note for CLIO III or MODUS.
Check the condition of the camshaft position sensor connector and its wiring (component code 1265).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
If the fault is still present, check, with the ignition on, for +12 V on connection 3FB of the camshaft sensor,
component code 1265.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
SIM32_V44_DF119/SIM32_V4C_DF119/SIM32_V54_DF119
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 120 of 348

17B-120V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF127
PRESENT
OR
STOREDBRAKE SWITCH 1 CIRCUIT
1.DEF: No signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is present after the ignition has been switched on and the brake pedal
has been depressed.
Special notes:
The fault appears after a fault on one of the two brake switch contacts.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check:
–the consistency of statuses ET704 Brake switch no. 1 and ET705 Brake switch no. 2 becoming ACTIVE -
INACTIVE when the brake pedal is depressed,
–the condition and cleanliness of the brake lights switch, component code 160.
Disconnect the battery and the injection computer, check the condition and cleanliness of the injection computer
connections, component code 120.
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation and continuity of the following connection:
●5A between components 120 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, carry out a fault finding procedure on the Anti-lock Braking System (see 38C, Anti-lock
Braking System).
If the fault is still present, contact the Techline.
SIM32_V44_DF127/SIM32_V4C_DF127/SIM32_V50_DF127/SIM32_V54_DF127
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 121 of 348

17B-121V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C
and 54
DF128
PRESENT
OR
STOREDBRAKE SWITCH 2 CIRCUIT
1.DEF: No signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is present after the ignition has been switched on and the brake pedal has
been depressed.
Special notes:
The fault appears after a fault on one of the two brake switch contacts.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check:
–the consistency of statuses ET704 Brake switch no. 1 and ET705 Brake switch no. 2 becoming ACTIVE -
INACTIVE when the brake pedal is depressed,
–the condition and cleanliness of the brake lights switch, component code 160.
Disconnect the battery and the injection computer, check the condition and cleanliness of the injection computer
connections, component code 120.
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation and continuity of the following connection:
●5A between components 120 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, carry out a fault finding procedure on the Anti-lock Braking System (see 38C, Anti-lock
Braking System).
If the fault is still present, contact the Techline.
SIM32_V44_DF128/SIM32_V4C_DF128/SIM32_V54_DF128
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.