DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -120V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF276
CONTINUED
2.DEF
NOTESThis fault appears on any blank computer (new or recently
reprogrammed).
WARNING
A computer without the IMA option can be replaced by a computer with this option. The codes are not
saved during command SC003 Save computer data.
In this case, status ET104 Use of Injector Codes becomes YES, fault DF276 Injector Code Programming
will be present, and the engine will operate in defect mode.
Program the injector codes using command SC002 Enter injector codes.
Carry out the procedure described in the Interpretation of commands section.
If the fault is still present after switching off the ignition, waiting 1 minute and then re-establish dialogue:
Follow the interpretation of command SC002 Entering injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -121V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF532
PRESENT
OR
STOREDALTERNATOR CHARGE SIGNAL
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Above maximum threshold
2.DEF : Below minimum threshold
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine
running.
Special notes:
If the fault is present, the level 1 warning light comes on.
IMPORTANT
The fault can appear after the alternator has been saturated for too long.
For stored faults, clear the fault, switch off the ignition and wait for 1 minute before
carrying out a road test to confirm the fault before any operation.
Run a multiplex network test (see 88B, Multiplexing).
If the fault is still present, check the insulation and continuity on the following connection:
Injection computer, connector C, track A3Alternator, Track 2, black connector
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF532
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -128V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF652
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Short circuit or open circuit to + 12 V
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present:
–ignition is on (CC.0),
–following a road test, engine warm (CO.1).
Special notes:
If the fault is present:
–the EGR function is inhibited,
–particle filter regeneration is inhibited,
–the vehicle performance is reduced,
–the level 1 warning light is illuminated.
Priorities when dealing with a number of faults:
DF011 Sensor voltage supply no. 1
IMPORTANT
The turbine upstream temperature sensor only measures temperatures above
200˚C.
Check the condition of the turbine upstream temperature sensor connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II, component code 1589).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II, component code 120).
If one of the connectors is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF652
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -130V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF778
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE CONTROL
1.DEF: Temperature measured too high
2.DEF: Parameter at max limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present:
–the engine is started with a speed greater than 1750 rpm and a fuel flow greater than
30 mg/st,
–a road test.
Special notes:
If the fault is present:
–particle filter regeneration is inhibited,
–the vehicle performance is reduced,
–the level 1 warning light is illuminated.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
Apply TEST 3 Turbocharged air inlet circuit check.
Check the turbine upstream temperature sensor connections.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF778
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -132V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF1070
PRESENT
OR
STOREDCOLD LOOP
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present with the engine running and with a heating and air
conditioning system request.
Priorities when dealing with a number of faults:
–DF049 Refrigerant sensor circuit if it is present or stored.
When the fault is present or stored, the heating and air conditioning system is inhibited.
Check fuse F22 (10A) of the UPC and the condition of the air conditioning compressor connector.
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the air conditioning compressor wiring.
If the wiring is faulty and there is a repair procedure (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Manually check if the compressor is jammed (turn the clutch plate manually to check that there is no point of
resistance). In the event of sticking, replace the air conditioning compressor (see MR 364 (Mégane II) or 370
(Scénic II), Mechanical, Heating and air conditioning system, 62A, Air conditioning, Compressor: Removal
- Refitting).
Top up the refrigerant, check for any leaks and repair if necessary (see MR 364 (Mégane II) or 370 (Scénic II),
Mechanical, Heating and air conditioning system, 62A, Air conditioning, Refrigerant circuit: check,
Refrigerant circuit: Draining - Filling).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF1070
DIESEL INJECTION
Fault finding – Conformity check13B
13B - 133V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM NO.: C1
Vdiag No.: 51DIESEL INJECTION
Fault finding – Conformity check
MAIN COMPUTER STATUSES AND PARAMETERS
NOTESOnly check conformity after a complete check using the diagnostic tool. The values
shown in this conformity check are given as a guide.
Test conditions: ENGINE OFF, IGNITION ON.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Vehicle impactET077:Impact
detectedNOIn the event of a fault, refer
to the interpretation of
fault DF069 Impact
detected signal.
2Power supplyET001:Computer
+ after ignition
feedPRESENTIn the event of a fault, refer
to the interpretation of
DF015 Main relay
control circuit.
PR071:Computer
feed voltage9 V < X < 16 VIn the event of a fault,
carry out a fault finding
procedure on the charging
circuit and refer to the
interpretation for DF047
Computer supply
voltage.
PR358:Sensor
reference
voltage3.4 V < X <3.8 VNone
3SpeedPR190:Engine idle
speed
setpoint.Indicates the engine's
rotational speed setpoint
in rpm.In the event of a fault, refer
to the interpretation for
fault DF005 Engine
speed sensor circuit.
PR055:Engine speedGives the engine's rotational
speed in rpm.
With the ignition on
at 0 rpm
4Speed signalPR089:Vehicle
speedGives the vehicle speed in
mph. This parameter is
transmitted by the ABS
computer. This signal is
transmitted to the injection
on the multiplex network.In the event of a fault, test
the multiplex network.
(See 88B, Multiplexing).
EDC16_V51_CCONF
MR-372-J84-13B250$450.mif
DIESEL INJECTION
Fault finding – Conformity check13B
13B - 134V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM NO.: C1
Vdiag No.: 51
MAIN COMPUTER STATUSES AND PARAMETERS (CONTINUED)
NOTESOnly check conformity after a complete check using the diagnostic tool. The values
shown in this conformity check are given as a guide.
Test conditions: ENGINE OFF, IGNITION ON.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
5Injection
configurationET104:Injector code useYESThis status indicates that
the IMA function is
activated. In the event of a
fault, consult the
interpretation of DF276
Injector code
programming.
6PressurePR035:Atmospheric
pressureIndicates the
atmospheric pressure
in mbar.
The sensor is built
into the computer.
Default value:
750 mbar.In the event of a fault,
consult the interpretation
of DF003 Atmospheric
pressure sensor circuit.
PR038:Rail pressure0 < X < 30 barIn the event of a fault,
consult the interpretation
of fault DF007 Rail
pressure sensor circuit.
7
TemperaturePR059:Inlet air
temperatureShows the inlet air
temperature
Ignition on PR061 =
PR059
Default value: 20 ˚CIn the event of a fault, refer
to the interpretation for
DF039 Inlet air
temperature circuit
sensor
8PR064:Coolant
temperatureShows the engine
coolant temperature
in ˚C
Default value: 119 ˚CIn the event of a fault, refer
to the interpretation of
DF001 Coolant
temperature sensor
circuit.
9TorquePR015:Engine torqueThis parameter is only
valid when the engine has
been started.
10Charging circuitPR016:Alternator flow0 mAIn the event of a fault,
check the charging circuit.
DIESEL INJECTION
Fault finding – Conformity check13B
13B - 135V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM NO.: C1
Vdiag No.: 51
AIR CIRCULATION (TURBOCHARGING/INLET)
*Opening cyclic ratio signal
NOTESOnly check conformity after a complete check using the diagnostic tool. The values
shown in this conformity check are given as a guide.
Test conditions: ENGINE OFF, IGNITION ON.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Engine speedPR055:Engine speedIndicates the engine's
rotational speed in rpm.
Ignition on at 0 rpmIn the event of a fault, refer
to the interpretation for
fault DF005 Engine
speed sensor circuit.
2TemperaturePR059:Inlet air
temperatureIndicates the inlet air
temperature
Default value: 20 ˚CIn the event of a fault, refer
to the interpretation of
fault DF039 Inlet air
temperature sensor
circuit
PR061:Exterior air
temperatureGives the exterior air
temperature in ˚C. This
parameter is controlled by
the UCH and transmitted
to the injection on the
multiplex network.
Default value: 20 ˚CIn the event of a fault, see
the UCH
(see 87B, Passenger
compartment
connection unit).
3TurbochargingPR009:Turbocharging
pressure
setpoint790 < X < 1,190 mbarNone
PR041:Turbocharging
pressurePR041 = PR035
± 10 mbarIn the event of a fault,
consult the interpretation
of DF004 Turbocharging
pressure sensor circuit.
PR047:Turbocharging
pressure OCR*X < 5 %
The Opening Cyclic Ratio
should be identical to the
correction of the solenoid
valve position PR011:Turbocharging
solenoid valve
position sensorX < 5 %