AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 113V3 MR-372-J84-23A000$540.mif
AJ0 BVA
Vdiag No.: 04, 05AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
DF308
PRESENT
OR
STOREDCOMPUTER EARTH
CO: Open circuit
NOTESSystem effects:
Fixed 5th gear engaged.
Customer complaint:
Fault warning light comes on.
Fixed 5th gear engaged.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Look for any damage to the harness and check the condition and connection of the transmission computer
connector and earths N* and MC3.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity of the following connections:
●Connection code N*, between components 119 and N*.
●Connection code 5LW between components 119 and MC3.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF308/AJ0_V05_DF308
MR-372-J84-23A000$540.mif