CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 5.CHECK IAT SENSOR
• Connect IAT sensor connector.
• Connect ECM connector.
• Turn ignition switch on.
• Check signal between IAT senso

Page 582 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM TERMINALNO. ITEM
CONDITION DATA (DC
VOLTAGE)
17 Sen

Page 583 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 2.CHECK IAT SENSOR ELECTRICAL CONNECTOR
• Disconnect the IAT sensor (IAT sensor is built-into)
electrical connector (1).
• Inspect the elec

Page 584 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine •Continuity should exist.
• Check harness for short to power.
Is the check result normal?
Ye s>>Go to the next step.
No
>>Repair circuit fo

Page 586 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM TERMINALNO. ITEM
CONDITION D ATA
(DC VOLTAGE)
39 En

Page 587 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 2.CHECK ENGINE COOLANT TEMPERATURE (ECT) SENSOR ELECTRICAL CONNECTOR
• Disconnect the ECT sensor electrical connector (1).
• Inspect the el

Page 588 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 5.CHECK ECT SENSOR
• Check resistance between ECT sensor terminal 1 and 2.
ECT°C RESISTANCE K
10°C 8.62 - 10.28
20°C 2.37 - 2.63
80°C 0.

Page 590 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM TERMINALNO. ITEM
CONDITION DATA (DC
VOLTAGE)
39 Eng