17C-46
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF092
CONTINUED
Replace the sensor if the pressure is no more than 0.8 bar greater than the manifold pressure PR001 Manifold
pressure.
Check the manifold pressure sensor sealing.
Check the pressure value using parameters PR001 Manifold pressure, PR003 Pressure difference:
LPG/manifold and PR112 LPG pressure downstream of expansion valve and ensure that
PR003 = PR112 - PR001.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
17C-47
MR-372-J84-17C000$413.mif
V2
17C
GAS INJECTION
Fault finding - Interpretation of faults
DF095
PRESENT
OR
STOREDLPG TEMPERATURE SENSOR CIRCUIT
1.DEF : Signal outside lower limit
2.DEF : Signal outside upper limit
3.DEF : Non-compliance with emission control standards
IMPORTANT
Before working on an LPG supply circuit component, always refer to the appropriate section of the
Workshop Repair Manual (see 17D, LPG Injection, Introduction, Safety advice for all operations).
NOTESConditions for applying the fault finding procedure to stored faults:
–The fault is declared present after the engine has been started and switched to LPG
mode.
Manipulate the wiring harness between the LPG computer and the LPG temperature/pressure sensor in order to
produce a change in status (present to stored).
Look for any damage to the harness, and check the connection and condition of the LPG pressure/temperature
sensor and its connectors.
If necessary, repair or replace the connector.
Check for + 5 V on track 3 of the LPG pressure/temperature sensor in LPG mode.
Check the following connections for insulation from earth, continuity and absence of extraneous resistance:
LPG computer track A3 track 3 of the LPG pressure/temperature sensor
Repair if necessary.
Check for earth on track 1 of the LPG pressure/temperature sensor in LPG mode.
Check the following connections for insulation from +5 V, continuity and absence of extraneous resistance:
LPG computer track B3 track 1 of the LPG pressure/temperature sensor
Repair if necessary.
Check the insulation, the continuity and absence of unwanted resistance on the connection between:
LPG computer track E2 track 2 of the LPG pressure/temperature sensor
Repair if necessary.
Measure the resistance of the temperature sensor.
Replace the sensor if the resistance is not: 2.5 kΩ ± 0.1 kΩ at 20 ˚C
1.2 kΩ ± 0.1 Ω at 40 ˚C
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF095 / GAZ3000_V10_DF095
LPG 3000
Program No: AB
Vdiag No: 08/10
MR-372-J84-17C000$413.mif
17C-48
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF096
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE
1.DEF : Voltage outside permitted range of values
2.DEF : Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for 10 seconds in
LPG mode.
Manipulate the wiring harness between the LPG computer and the LPG temperature/ pressure sensor in order to
produce a change in status (present ↔ stored).
Look for any damage to the harness, and check the connection and condition of the LPG pressure/temperature
sensor and its connectors.
If necessary, repair or replace the connector.
Check for + 5 V on track A4 and A3 (for Mégane 2) and on track B2 and A3 (for Logan) and for earth on
track B3 and D3 (for Mégane 2) or tracks G1 and H1 (for Logan) of the LPG computer.
Repair if necessary.
If incorrect, contact the Techline.
Check for a supply on tracks A3 and A4 of the LPG computer.
The voltage value must be between:
4.8 < V < 5.2
Check the insulation and continuity of the following connections:
For Mégane 2:
LPG computer track A4
LPG computer track A3
For Logan:
LPG computer track B2
LPG computer track A3track B of the LPG tank sender
track 1 of the LPG pressure sensor
track A2 of the LPG tank sender
track 3 of the LPG pressure sensor
Repair if necessary.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF096 / GAZ3000_V10_DF096
17C-49
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF098
PRESENT
OR
STOREDCYLINDER 1 INJECTOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Non-compliance with emission control standards
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode or when
command AC021 Cylinder 1 injector is executed.
Manipulate the wiring harness between the injection computer and the cylinder 1 injector in order to produce a change in
status
(present ↔ stored).
Look for any harness damage, and check the condition and connection points of the injector and its connections.
If necessary, repair or replace the connector.
Measure the resistance of injector 1 between tracks 1 and 2.
The injector resistance value at roughly 20 °C must be between:
0.77 Ω < R < 1.43 Ω
Replace the injector if necessary.
Check for insulation against earth, continuity and absence of interference resistance for the following connections:
For Mégane 2:
General relay track 5
Black intermediate connector (R37) track 5
LPG computer track G3
Black intermediate connector (R37) track 1
For Logan:
Injector 1 track 1
LPG computer track G3track 15 of the black intermediate connector (R37)
track 1 of injector 1
track 1 of the black intermediate connector (R37)
track 2 of injector 1
track A1 of the double relay control unit relay
track 2 of injector 1
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF098 / GAZ3000_V10_DF098
17C-50
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF098
CONTINUED
With the ignition on,
–check for +12 V on track 1 of injector 1,
–check for earth on track 2 of injector 1 when command AC021 Cylinder 1 injector is executed.
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
17C-51
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF099
PRESENT
OR
STOREDINSTRUMENT PANEL INDICATOR LIGHT CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been started and switched to LPG
mode.
Special note:
Status ET099 LPG system faulty may help in dealing with this fault.
Check the insulation and continuity on the wires of the following multiplex connections:
For Mégane 2:
LPG computer track A1
LPG computer track A2
LPG computer track A2
For Logan:
LPG computer track C1
LPG computer track E1
LPG computer track D4track 17 of the instrument panel
track 18 of the instrument panel
track 4 of the instrument panel
track 23 of the instrument panel
track 11 of the instrument panel
track 19 of the instrument panel
Repair if necessary.
If the LPG in operation indicator light does not light up normally, carry out fault finding on the instrument
panel (see 83A, Instrument panel).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF099 / GAZ3000_V10_DF099
17C-52
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF103
PRESENT
OR
STOREDLPG EXPANSION VALVE SOLENOID VALVE CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Non-compliance with emission control standards
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with it
first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode or
when command AC024 LPG expansion solenoid valve is executed.
Manipulate the wiring harness between the LPG computer and the LPG expansion valve solenoid valve in order
to produce a change in status (present ↔ stored).
Look for possible damage to the harness, and check the condition and connection of the LPG expansion valve
solenoid valve and its connectors.
Repair if necessary.
Measure the resistance between tracks 1 and 2 of the LPG expansion valve solenoid valve.
Replace the solenoid valve if the resistance is not approximately 12.6 Ω ± 1.3Ω .
Check the following connections for insulation from earth, continuity and absence of extraneous resistance:
For Mégane 2:
LPG expansion valve solenoid valve track 1
For Logan:
LPG expansion valve solenoid valve track 1
Intermediate connector (R674) track 1track 5 of the main relay
Intermediate connector (R674) track 1
track A3 of the main relay
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF103 / GAZ3000_V10_DF103
17C-53
MR-372-J84-17C000$413.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF103
CONTINUED
Check the following connections for insulation from +12 V, continuity and absence of extraneous resistance:
For Mégane 2:
LPG expansion valve solenoid valve track 2
For Logan:
LPG expansion valve solenoid valve track 2
Intermediate connector (R674) track 2track G2 of the LPG computer
Intermediate connector (R674) track 2
track G2 of the LPG computer
Repair if necessary.
With the engine running, check that the LPG expansion valve solenoid valve clicks when the LPG mode is
selected or command AC024 LPG expansion valve solenoid valve is executed.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.