17C-38
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF081
PRESENT
OR
STOREDCYLINDER 2 INJECTOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 Volts
1.DEF: Non-compliance with emission control standards
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with
this fault first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode
or when command AC020 Cylinder 2 injector is executed.
Manipulate the wiring harness between the LPG computer and Injector number 2 until there is a change in status.
(present ↔ stored).
Look for any damage to the wiring harness and check the connection and condition of injector 2 and its
connections.
If necessary, repair or replace the connector.
Measure the resistance of injector 2 between tracks 1 and 2.
Replace the injector if the resistance value of the injector at approximately 20°C is not between:
0.7 Ω < R < 1.45 Ω
Check for insulation against earth, continuity and absence of interference resistance for the following
connections:
For Mégane 2:
General relay track A5
Black intermediate connector (R37) track 6
LPG computer track G4
Black intermediate connector (R37) track 2
For Logan:
Injector 2 track 1
LPG computer track G4track 6 of the black intermediate connector (R37)
track 1of injector 2
track 2 of the black intermediate connector (R37)
track 2 of injector 2
track A1 of the double control relay unit
track 2 of injector 2
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF081 / GAZ3000_V10_DF081
17C-39
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF081
CONTINUED
With the ignition on,
–check for + 12V on track 1 of injector 2,
–check for earth on track 2 of injector 2 when command AC020 Cylinder 2 injector is run.
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
17C-40
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF083
PRESENT
OR
STOREDLPG PRESSURE SENSOR CIRCUIT
CC.0: Short circuit to earth
CO.1: Open circuit or short circuit to + 12V
1.DEF: Non-compliance with emission control standards
NOTESNone
Special note:
The fault is declared present when the ignition is switched on.
Manipulate the wiring harness between the Gas computer and the gas pressure sensor in order to produce
a change in status (present to stored).
Look for any damage to the wiring harness and check the connection and condition of the LPG pressure/
temperature sensor and its connections.
Replace or repair the connector(s) if necessary.
Check for + 5V on track 1 of the LPG pressure/temperature sensor in LPG mode.
Check the insulation in relation to earth and the continuity and the absence of interference resistance on
the connection between:
LPG computer track A3 track 1 of the LPG temperature/pressure sensor
Repair if necessary.
Check for earth on track 3 of the LPG temperature/pressure sensor in LPG mode.
Check the insulation in relation to + 12V and the continuity and absence of interference resistance on
the connection between:
LPG computer track B3 track 3 of the LPG temperature/pressure sensor
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance on the connection between:
LPG computer track C4 track 2 of the LPG pressure/temperature sensor
Repair if necessary.
Replace the sensor if the LPG pressure is not greater than 2.5 bar in relation to the manifold pressure
PR001 Manifold pressure.
Check the pressure value using parameters PR001 Manifold pressure, PR003 Pressure difference:
LPG/manifold and PR112 LPG pressure downstream of expansion valve and ensure that
PR003 = PR112 - PR001.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF083 / GAZ3000_V10_DF083
17C-41
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF087
PRESENT
OR
STOREDCYLINDER 4 INJECTOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 Volts
1.DEF: Non-compliance with emission control standards
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with
this fault first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode
or when command AC018 Cylinder 4 injector is executed.
Manipulate the wiring harness between the LPG computer and Injector number 4 to produce a change in status.
(present ↔ stored).
Look for any harness damage, and check the condition and connection of injector no. 4 and its connectors.
If necessary, repair or replace the connector.
Measure the resistance of injector 4 between tracks 1 and 2.
The injector resistance value at approximately 20°C should be between:
0.7 Ω < R < 1.45 Ω
Replace the injector if necessary.
Check for insulation against earth, continuity and absence of interference resistance for the following
connections:
For Mégane 2:
General relay track 5
Black intermediate connector (R37) track 8
LPG Computer track H3
Black intermediate connector (R37) track 4
For Logan:
Injector 4 track 1
LPG Computer track H3track 8 of the black intermediate connector (R37)
track 1of injector 4
track 4 of the black intermediate connector (R37)
track 2 of injector 4
track A1 of the double control relay unit
track 2 of injector 4
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF087 / GAZ3000_V10_DF087
17C-42
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF087
CONTINUED
With the ignition on,
–check for + 12V on track 1 of injector 4,
–check for earth on track 2 of injector 4 when command AC018 Cylinder 4 injector is run.
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
17C-43
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF088
PRESENT
OR
STOREDCYLINDER 3 INJECTOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 Volts
1.DEF: Non-compliance with emission control standards
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESPriority when dealing with a number of faults:
If fault DF021 LPG tank solenoid valve relay circuit is present or stored, deal with
this fault first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode
or when command AC019 Cylinder 3 injector is executed.
Manipulate the wiring harness between the LPG computer and Injector number 3 to produce a change in status.
(present ↔ stored).
Look for any damage to the wiring harness and check the connection and condition of the injector and its
connections.
If necessary, repair or replace the connector.
Measure the resistance of injector 3 between tracks 1 and 2.
The injector resistance value at approximately 20°C should be between:
0.7 Ω < R < 1.45 Ω
Replace the injector if necessary.
Check for insulation against earth, continuity and absence of interference resistance for the following
connections:
For Mégane 2:
General relay track 5
Black intermediate connector (R37) track 7
LPG computer track H2
Black intermediate connector (R37) track 3
For Logan:
Injector 3 track 1
LPG computer track H2track 7 of the black intermediate connector (R37)
track 1of injector 3
track 3 of the black intermediate connector
track 2 of injector 3
track A1 of the double control relay unit
track 2 of injector 3
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF088 / GAZ3000_V10_DF088
17C-44
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF088
CONTINUED
With the ignition on,
–check for + 12V on track 1 of injector 3,
–check for earth on track 2 of injector 3 when command AC019 Cylinder 3 injector is run.
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
17C-45
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF092
PRESENT
OR
STOREDLPG PRESSURE SENSOR DOWNSTREAM OF EXPANSION VALVE
CO.0: Short circuit to earth
CC.1: Open circuit or short circuit to + 12V
1.DEF: Non-compliance with emission control standards
NOTESFault finding procedure application conditions:
Present or stored fault.
Manipulate the wiring harness between the LPG computer and the LPG pressure/temperature sensor in order to
produce a change in status (present ↔ stored).
Look for any damage to the wiring harness and check the connection and condition of the LPG pressure/
temperature sensor and its connections.
If necessary, repair or replace the connector.
Check for + 5V on track 1 (for Mégane 2) or track 3 (for Logan) of the LPG pressure/temperature sensor in LPG
mode.
Check the insulation in relation to earth and the continuity and the absence of interference resistance on
the connection between:
For Mégane 2:
LPG computer track A3
For Logan:
LPG computer track A3track 1 of the LPG temperature/pressure sensor
track 3 of the LPG temperature/pressure sensor
Repair if necessary.
Check for earth on tracks 3 and 1 of the LPG pressure/temperature sensor in LPG mode.
Check the insulation in relation to + 12V and the continuity and absence of interference resistance on
the connection between:
For Mégane 2:
LPG computer track B3
For Logan:
LPG computer track B3track 3 of the LPG temperature/pressure sensor
track 1 of the LPG temperature/pressure sensor
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance on the connection between:
For Mégane 2:
LPG computer track C4
For Logan:
LPG computer track E2track 2 of the LPG pressure/temperature sensor
track 2 of the LPG pressure/temperature sensor
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF092 / GAZ3000_V10_DF092