Page 17 of 46

86D-17
MR-372-J84-86D000$504.mif
V2
MULTIMEDIA NETWORK INTERFACE UNIT
Fault finding - Interpretation of faults
Multimedia network
interface unit
Vdiag No: 04, 14
86D
DF005
PRESENT
OR
STOREDSUPPLY
1.DEF: Excess voltage
2.DEF: Undervoltage
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after the multimedia system has been switched on using
the on/off button.
Use the wiring diagrams Technical Note for Scénic II ph2, Espace IV ph2, Trafic II
ph2 or Kangoo 2.
Check the battery voltage,
Check the charging circuit (see Technical Note 6014A, Checking the charging circuit).
Check the condition of the multimedia network interface unit supply fuse.
If the supply fuse is correct, check for + 12 V on connection BCP4 (Kangoo 2), BCP4 (Trafic II ph2), BP3A
(Espace IV ph2) or BCP3 (Scénic II ph2).
If there is no + 12 V, check the continuity of connection BCP4 (Kangoo 2), BCP4 (Trafic II ph2),
BP3A (Espace IV ph2) or BCP3 (Scénic II ph2).
Check for earth on connection MAN (Kangoo 2), MAN (Trafic II ph2 and Scénic II ph2),
NC (Espace IV ph2).
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fuse is not correct, check the insulation against earth on connection BCP4 (Kangoo 2), BCP4 (Trafic II
ph2), BP3A (Espace IV ph2) or BCP3 (Scénic II ph2).
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the fuse.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other possible faults.
BIC_V04_DF005/BIC_V14_DF005
Page 32 of 46

86D-32
MR-372-J84-86D000$784.mif
V2
86D
MULTIMEDIA NETWORK INTERFACE UNIT
Fault finding - Interpretation of parameters
PR002
BATTERY VOLTAGE
NOTESThere must be no present or stored faults.
Engine stopped, ignition on.
Use the wiring diagrams Technical Note for Scénic II ph2, Espace IV ph2, Trafic II
ph2 or Kangoo 2.
Check the permanent + supply fuse of component 1714.
Check the condition of the connectors of the components supplying the multimedia network interface unit
depending on the location of the fuse.
If the voltage is at minimum:
Check the battery and the charge circuit:
–Scénic II ph2 and Kangoo 2, see 87G, Engine compartment connection unit.
–Espace II ph2 and Trafic II ph2, see Technical Note 6014A, Checking the charging circuit.
If the voltage is at maximum:
Check that the charging voltage is correct with and without electrical consumers switched on.
Check the insulation, continuity and the absence of interference resistance of the following connections:
Scénic II ph2:
–connection code BCP3 between components 1714 and 260.
–connection code MAN between component 1714 and earth MAN.
Kangoo 2:
–connection code BCP4 between components 1714 and 260.
–connection code MAN between component 1714 and earth MAN.
Espace IV ph2:
–connection code BP3A between components 1714 and 260.
–connection code NC between component 1714 and earth NC.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRRepeat the conformity check from the start.
BIC_V04_PR002/BIC_V14_PR002
Multimedia network
interface unit
Vdiag No.: 04, 14
MR-372-J84-86D000$784.mif
Page 35 of 46

86D-35
MR-372-J84-86D000$784.mif
V2
MULTIMEDIA NETWORK INTERFACE UNIT
Fault finding - Interpretation of parameters
Multimedia network
interface unit
Vdiag No.: 04, 14
86D
PR011
BATTERY VOLTAGE
NOTESThere must be no present or stored faults.
Use the wiring diagrams Technical Note for Scénic II ph2, Espace IV ph2, Trafic II
ph2 or Kangoo 2.
Check the permanent + supply fuse of component 261.
If the voltage is at minimum:
Check the battery and the charge circuit:
–Scénic II ph2 and Kangoo 2, see 87G, Engine compartment connection unit.
–Espace II ph2 and Trafic II ph2, see Technical Note 6014A, Checking the charging circuit.
If the voltage is at maximum:
Check that the charging voltage is correct with and without electrical consumers switched on.
Check the insulation, continuity and the absence of interference resistance of the following connections:
Scénic II ph2:
–connection code BCP3 between components 1714 and 260.
–connection code MT between component 261 and earth MT.
Espace IV ph2:
–connection code BCP4 between components 261 and 710.
–connection code MV between component 261 and earth MV.
Kangoo 2:
–connection code BP26 between components 261 and 260.
–connection code MT between component 261 and earth MT.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRRepeat the conformity check from the start.
BIC_V04_PR011/BIC_V14_PR011