AUTOMATIC TRANSMISSION
Fault finding – Conformity check23A
23A - 74V4 MR-372-J84-23A050$462.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
SUB-FUNCTION: CREEPING AT IDLE SPEED
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Oil pressurePR003:Oil pressureX < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
2Oil temperaturePR004:Gearbox oil
temperature-40 ˚C < X < 140 ˚C In the event of a
fault, consult the
interpretation of this
parameter.
3Engine speedPR006:Engine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
4Engine speedPR007:Turbine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
5Engine/turbine
speed differencePR128:Engine/turbine
speed difference0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-80V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET010
OIL TOO HOT SIGNAL
NOTESThere must be no present or stored faults.
This status means the oil temperature is above the normal operation temperature.
The status displays NO if the gearbox oil temperature is below 140˚C.
The status changes to YES when the gearbox oil temperature rises above 140˚C.
If the correct status is not displayed, use the interpretation of fault DF177 Automatic transmission overheating.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_ET010/DP0TA2000_V11_ET010/DP0TA2000_V15_ET010
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-84V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
* EV: Solenoid valve.ET020
EXCHANGER FLOW CONTROL SOLENOID VALVE*
NOTESThere must be no present or stored faults.
The exchanger flow control solenoid valve is ACTIVE when the gearbox oil temperature exceeds 100˚C
and the engine speed exceeds 2000 rpm.
Otherwise the solenoid valve remains inactive.
Run command AC024 Actuator sequential control and check that the activation status changes from INACTIVE
to ACTIVE.
When powered, if the solenoid valve is ACTIVE the voltage should be 0 V.
When powered, if the solenoid valve is INACTIVE the voltage should be 12 V.
Reconnect the computer.
Activate the solenoid valves with command AC024 Actuator sequential control and check the solenoid valve
current.
If the current is 260 mA, the solenoid valve is working properly.
If the current is weaker, check the computer connections and harness up to the exchanger flow solenoid valve.
If the status of the command fails to change, use the interpretation of fault DF017 Exchanger flow solenoid valve
circuit.
If the fault is still present after the fault finding procedure for fault DF017 Exchanger flow solenoid valve circuit
has been followed, contact your Techline.
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2000_V10_ET020/DP0TA2000_V11_ET020/DP0TA2000_V15_ET020
AUTOMATIC TRANSMISSION
Fault finding – Parameter summary table23A
23A - 100V4 MR-372-J84-23A050$660.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
Tool parameter Diagnostic tool title
PR001Coolant temperature
PR003Oil pressure
PR004Gearbox oil temperature
PR006Engine speed
PR007Turbine speed
PR008Computer feed voltage
PR128Engine/turbine speed difference
PR135Standard pedal position
PR138Reference pressure
PR146Difference between reference and pressure
AUTOMATIC TRANSMISSION
Fault finding – Parameter interpretation23A
23A - 102V4 MR-372-J84-23A050$726.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
PR003
OIL PRESSURE
NOTESThere must be no present or stored faults.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer.
Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference resistance
on the following connections:
●Connection code 5U between components 119 and 781.
●Connection code 5W between components 119 and 781.
●Connection code 5V between components 119 and 781.
●Connection code 5AZ, between components 119 and 754.
●Connection code 5BA between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Reconnect the modular connector.
Measure the resistance of component 781 between the following connections:
●Connection code 5U.
●Connection code 5W.
The value should be approximately 20 kΩ.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the value is not correct, replace the sensor.
Measure the resistance of component 754 between the following connections:
●Connection code 5AZ.
●Connection code 5BA.
The value should be approximately 1 Ω ± 0.2 Ω at 20 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the value is not correct, the solenoid valve or the electric/hydraulic interface harness is damaged.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling-Levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Draining-Filling (for Scénic II)).
Check that the gearbox is not leaking oil.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_PR003/DP0TA2000_V11_PR003 /DP0TA2000_V15_PR003
AUTOMATIC TRANSMISSION
Fault finding – Parameter interpretation23A
23A - 103V4 MR-372-J84-23A050$726.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
PR003
CONTINUED
See the Taking line pressure section of the Workshop Repair Manual.
Set up the pressure gauge for a line pressure reading.
With a warm engine and the gearbox oil temperature between 60 and 80 ˚C, check the difference between the line
pressure sensor (PR003) and the pressure gauge under the following conditions:
–with the engine stopped, the pressure gauge should indicate a residual pressure of about 0.2 bar.
If the sensor reading differs by more than 0.2 bar, replace the sensor.
–with the engine running at about 1200 rpm the pressure gauge reading should reach 7 bar.
If the sensor reading differs by more than 0.8 bar, replace the sensor.
Warm engine with gearbox oil temperature between 60 and 80 ˚C.
Take the line pressure readings under the following conditions:
–with the gear lever in P or N and engine speed at 2000 rpm the pressure should be between 2.6 and 3.2 bar.
–with the gear lever at R and engine speed at 2000 rpm, the pressure should be above 4 bar.
–with the gear lever at D and engine speed at 2000 rpm, the pressure in first gear should be greater than 7 bar.
If the values are not correct, there is a fault inside the gearbox.
AFTER REPAIRRepeat the conformity check from the start.
AUTOMATIC TRANSMISSION
Fault finding – Parameter interpretation23A
23A - 104V4 MR-372-J84-23A050$726.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
PR004
GEARBOX OIL TEMPERATURE
NOTESThere must be no present or stored faults.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer.
Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference resistance
on the following connections:
●Connection code 5BC between components 119 and 754.
●Connection code 5BB, between components 119 and 754.
●Connection code 5DN between components 119 and 1019.
●Connection code 5DD between components 119 and 1019.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●Connection code 5BC.
●Connection code 5BB.
The value should be between 2360 and 2660 Ω at a temperature of 20 ˚C and between 290 and 327 Ω at a
temperature of 80 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the value is not correct, the sensor or the electric/hydraulic interface harness is damaged.
Measure the resistance of component 1019 between the following connections:
●Connection code 5DN.
●Connection code 5DD.
The value should be approximately 40 Ω ± 4 Ω at 20 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the value is not correct, the solenoid valve or the electric/hydraulic interface harness is damaged.
Make sure that the water-oil exchanger is not blocked.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_PR004/DP0TA2000_V11_PR004 /DP0TA2000_V15_PR004
AUTOMATIC TRANSMISSION
Fault finding – Parameter interpretation23A
23A - 107V4 MR-372-J84-23A050$726.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
PR128
ENGINE/TURBINE SPEED DIFFERENCE
NOTESThere must be no present or stored faults.
Check gearbox oil grade and level.
If an oil change or top-up is necessary see the Draining-Filling-Levels section of the Workshop Repair Manual.
Check that the gearbox is not leaking oil.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference
resistance on the following connections:
●Connection code 5DA between components 119 and 1017.
●Connection code 5DB between components 119 and 1017.
●Connection code 5BX between components 119 and 754.
●Connection code 5BA between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 1017 between the following connections:
●Connection code 5DA.
●Connection code 5DB.
The value should be approximately 300 Ω ± 40 Ω at a temperature of approximately 20 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is not correct, either the sensor or the harness is damaged. Replace the faulty component.
Measure the resistance of component 754 between the following connections:
●Connection code 5BX.
●Connection code 5BA.
The value should be approximately 1 Ω ± 0.2 Ω at 20 ˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the value is not correct, the solenoid valve or the electric/hydraulic interface harness is damaged.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_PR128/DP0TA2000_V11_PR128 /DP0TA2000_V15_PR128