GENERAL INFORMATION
ENGINE COOLING14-2
GENERAL INFORMATIONM2140000100780
The cooling system is a water-cooled pressurized,
forced circulation type which offers the following fea
-
tures.
•To stabilize engine coolant temperature, the ther-
mostat is located at the coolant inlet port from the
radiator.
•To improve engine cooling performance and save
weight, a plastic tank and aluminum radiator fins
are used.
SPECIFICATIONS
CONSTRUCTION DIAGRAM
ItemSpecification
Cooling methodWater-cooled pressurized, forced
circulation with electrical fan
RadiatorTy p ePressurized corrugate type
Performance kJ/h (kcal/h)222,480 (53,148)
Water pumpTy p eCentrifugal impeller
Drive methodDrive belt
ThermostatTy p eWax pellet with jiggle valve
Valve open temperature °C (°F)82 (180)
AC608448
Condenser fan motor Radiator assemblyRadiator upper hose
assembly
Radiator condenser
tank assembly Radiator fan motor
Cooling fan shroud
Radiator lower hose Transmission oil
cooler line hose
and tube assembly
AB
WATER PASSAGE
ENGINE COOLING14-3
WATER PASSAGEM2140004000172
NOTE: EGR: Exhaust Gas Recirculation
CVT: Continuously Variable Transmission
WAT E R P U M PM2140003000168
The water pump is the centrifugal, impeller type that
is installed in front of the cylinder block. It is driven by
the drive belt.
AK603624
Water pump
EGR
AB
Thermostat
Radiator Throttle body
CVT oil
coolerHeater
Water pump
EGR
Thermostat
Radiator Throttle body
CVT oil
cooler Heater
AK503034
Impeller
AD
ItemSpecifications
Discharge volume L/min185
Impeller diameter mm (in)62 (2.4)
Pulley outer diameter mm