HAC-62
< COMPONENT DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
REAR AIR CONTROL SYSTEM
1. Start and run engine to operating temperature.
2. Turn the rear blower motor to maximum speed from the rear air control (front).
3. Turn rear air control (front) temperature control dial clockwise and then counterclockwise (REAR CTRL
indicator off).
4. Check for hot air at rear discharge air outlets in the maximum heat position and cold air at discharge air outlets in the maximum cold position.
Does the rear air control (front) operate properly?
YES >> GO TO 3.
NO >> Check rear air control (front). Refer to HAC-62, "
Air Mix Door Motor (Rear) Diagnosis Procedure".
3.CONFIRM SYMPTOM BY PERFORMING REAR AIR CO NTROL (REAR) AIR MIX DOOR MOTOR OPER-
ATIONAL CHECK
1. Press the REAR CTRL switch on rear air control (front) to send control to the rear air control (rear).
2. Turn rear air control (rear) temperature control dial slowly clockwise and then counterclockwise (REAR
CTRL indicator on).
3. Check for hot air at rear discharge air outlets in the maximum heat position and cold air at rear discharge
air outlets in the maximum cold position.
Does the rear air control (rear) operate properly?
YES >> GO TO 4.
NO >> Check rear air control (rear). Refer to HAC-58, "
Rear Air Control (Rear) Diagnosis Procedure #2".
4.CONFIRM SYMPTOM BY PERFORMING REAR AIR CONTROL (FRONT) MODE OPERATIONAL CHECK
1. Press the REAR CTRL switch on rear air control (front) (REAR CTRL indicator off).
2. Press each mode switch and check for proper air discharge at the appropriate locations.
Does the rear air control (front) operate properly?
YES >> GO TO 5.
NO >> Check mode door motor (rear). Refer to HAC-66, "
Mode Door Motor (Rear) Diagnosis Proce-
dure".
5.CONFIRM SYMPTOM BY PERFORMING REAR AIR CONTROL (REAR) MODE OPERATIONAL CHECK
1. Press the REAR CTRL switch on rear air control (f ront) to send control to the rear air control (rear).
2. Press each mode switch and check for proper air discharge at the appropriate locations.
Does the rear air control (rear) operate properly?
YES >> System OK.
NO >> Replace rear air control (rear). Refer to VTL-7, "
Removal and Installation".
Air Mix Door Motor (Rear) Diagnosis ProcedureINFOID:0000000001679806
DIAGNOSTIC PROCEDURE FOR INOPERATIVE AIR MIX DOOR MOTOR (REAR)
SYMPTOM:
• Temperature control (rear) operation is malfunctioning.
1.CHECK REAR AIR CONTROL (FRONT) POWER SUPPLY
1. Disconnect rear air control (front) harness connector.
2. Turn ignition switch ON.
3. Check voltage between rear air control (front) harness connec- tor R108 terminal 1 and ground.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair harness or connector.
2.CHECK REAR AIR CONTROL (FRONT) LIN BUS VOLTAGE
Battery voltage should exist.
AWIIA0182ZZ
Revision: March 2010
2008 QX56
HAC-74
< COMPONENT DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
MAGNET CLUTCH
1. Reconnect BCM connector and A/C auto amp. connector.
2. Turn ignition switch ON.
3. Check voltage between A/C auto amp. harness connector M49
terminal 4 and ground.
Is the inspection result normal?
YES >> GO TO 8.
NO-1 >> If the voltage is approx. 5V when A/C switch is ON, replace A/C auto amp. Refer to VTL-7,
"Removal and Installation".
NO-2 >> If the voltage is approx. 0V when A/C switch is OFF, replace BCM. Refer to BCS-55, "
Removal
and Installation".
8.CHECK REFRIGERANT PRESSURE SENSOR
1. Start engine.
2. Check voltage between ECM harness connector F54 terminal 70 and ground.
Is the inspection result normal?
YES >> GO TO 9.
NO >> Refer to EC-423, "
Diagnosis Procedure".
9.CHECK BCM INPUT (FAN ON) SIGNAL
Check FAN ON/OFF signal. Refer to HAC-20, "
CONSULT-III Function (HVAC)".
Is the inspection result normal?
YES >> GO TO 12.
NO >> GO TO 10.
10.CHECK CIRCUIT CONTINUITY BETW EEN BCM AND A/C AUTO AMP.
Te r m i n a l s
Condition Voltage
(+)
(-)
A/C auto
amp. con-
nector Te r m i n a l N o .
M49 4 Ground A/C switch: ON Approx. 0V
A/C switch: OFF Approx. 5V
AWIIA0200ZZ
Te r m i n a l s
ConditionVoltage
(+)
(-)
ECM con-
nector Te r m i n a l N o .
F54 70 Ground A/C switch: ON Approx. 0.36 - 3.88V
LJIA0124E
FRONT BLOWER CONTROL
DIAL ON : FAN ON SIG ON
FRONT BLOWER CONTROL
DIAL OFF : FAN ON SIG OFF
Revision: March 2010
2008 QX56
HAC-76
< COMPONENT DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
WATER VALVE CIRCUIT
WATER VALVE CIRCUIT
DescriptionINFOID:0000000001679811
COMPONENT DESCRIPTION
Water Valve
The water valve (1) cuts the flow of engine coolant to the front and
rear heater cores to allow for maximum cooling during A/C opera-
tion. It is controlled by the A/C auto amp.
Water Valve Diagnosis ProcedureINFOID:0000000001679812
DIAGNOSTIC PROCEDURE FOR WATER VALVE
1.CHECK WATER VALVE POWER AND GROUND CIRCUITS
1. Disconnect water valve connector F68.
2. Turn ignition switch ON.
3. Rotate temperature control dial (driver) to 32 °C (90° F).
4. Check voltage between water valve harness connector F68 ter- minal 1 and terminal 2 while rotating temperature control dial
(driver) to 18 °C (60° F).
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK WATER VALVE CONTROL OUTPUT CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect A/C auto amp. connector M50.
3. Check continuity between water valve harness connector F68 (A) terminal 2 and A/C auto amp. harness connector M50 (B)
terminal 46.
4. Check continuity between water valve harness connector F68 (A) terminal 2 and ground.
Is the inspection result normal?
YES >> Replace A/C auto amp. Refer to VTL-7, "Removal and Installation".
NO >> Repair harness or connector.
3.CHECK WATER VALVE POWER AND GROUND CIRCUITS
WJIA1791E
Connector Te r m i n a l s
Condition Voltage
(Approx.)
(+) (-)
Water valve: F68 2 1Rotate temperature
control dial Battery
voltage
WJIA1794E
2 - 46 : Continuity should exist.
2 - Ground : Continuity should not exist.
AWIIA0203ZZ
Revision: March 2010 2008 QX56
HAC-78
< COMPONENT DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
AMBIENT SENSOR
AMBIENT SENSOR
Component DescriptionINFOID:0000000001679813
COMPONENT DESCRIPTION
Ambient Sensor
The ambient sensor (1) is attached on the radiator core support (left
side). It detects ambient temperature and converts it into a value
which is then input into the A/C auto amp.
AMBIENT TEMPERATURE INPUT PROCESS
The A/C auto amp. includes a processing circuit for the
ambient sensor input. However, when the temperature
detected by the ambient sensor increas es quickly, the processing circuit retards the A/C auto amp. function. It
only allows the A/C auto amp. to recognize an ambient temperature increase of 0.33°C (0.6°F) per 100 sec-
onds.
This prevents constant adjustments due to momentary conditions, such as stopping after high speed driving.
Although the actual ambient temperature has not changed, the temperature detected by the ambient sensor
will increase. This is because the heat from the engine co mpartment can radiate to the front grille area, loca-
tion of the ambient sensor.
Ambient Sensor Diagnosis ProcedureINFOID:0000000001679814
DIAGNOSTIC PROCEDURE FOR AMBIENT SENSOR
SYMPTOM: Ambient sensor circuit is open or shorted. (40 or 41 is
indicated on A/C auto amp. as a result of conducting the A/C auto
amp. self-diagnosis)
1.CHECK VOLTAGE BETWEEN AM BIENT SENSOR AND GROUND
1. Disconnect ambient sensor connector.
2. Turn ignition switch ON.
3. Check voltage between ambient sensor harness connector E1 terminal 1 and ground.
Is the inspection result normal?
YES >> GO TO 2.
NO >> GO TO 4.
2.CHECK CIRCUIT CONTINUITY BETWEEN AM BIENT SENSOR AND A/C AUTO AMP.
AWIIA0238ZZ
AWIIA0160GB
1 - Ground: Approx. 5V
AWIIA0161ZZ
Revision: March 2010 2008 QX56
HAC-110
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
NO >> Check water valve circuit. Refer to
HAC-76, "Water Valve Diagnosis Procedure".
9.CHECK RECOVERY/RECYCLING EQUIPMENT BEFORE USAGE
Check recovery/recycling equipment before connecting to vehicle. Verify there is no pressure in the recovery/
recycling equipment by checking the gauges. If pressure exists, recover refrigerant from equipment lines.
>> GO TO 10.
10.CHECK REFRIGERANT PURITY
1. Connect recovery/recycling equipment to vehicle.
2. Confirm refrigerant purity in supply tank us ing recovery/recycling and refrigerant identifier.
Is the inspection result normal?
YES >> GO TO 11.
NO >> Check contaminated refrigerant. Refer to HAC-122, "
Working with HFC-134a (R-134a)".
11 .CHECK FOR EVAPORATOR FREEZE UP
Start engine and run A/C. Check for evaporator freeze up.
Does evaporator freeze up?
YES >> Perform diagnostic work flow. Refer to HAC-110, "Diagnostic Work Flow".
NO >> GO TO 12.
12.CHECK REFRIGERANT PRESSURE
Check refrigerant pressure with manifold gauge connected. Refer to HAC-113, "
Performance Chart".
Is the inspection result normal?
YES >> Perform diagnostic work flow. Refer to HAC-110, "Diagnostic Work Flow".
NO >> GO TO 13.
13.CHECK AIR DUCTS
Check ducts for air leaks.
Is the inspection result normal?
YES >> System OK.
NO >> Repair air leaks.
Diagnostic Work FlowINFOID:0000000001679831
Revision: March 2010 2008 QX56
HAC-114
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT COOLING
Trouble Diagnoses fo r Abnormal Pressure
INFOID:0000000001679834
Whenever system′s high and/or low side pressure is abnormal, diagnose using a manifold gauge. The marker
above the gauge scale in the following tables indicates the standard (usual) pressure range. Since the stan-
dard (usual) pressure, however, differs from vehicle to vehicle, refer to above table (Ambient air temperature-
to-operating pressure table).
Both High- and Low-pressure Sides are Too High
High-pressure Side is Too High and Low-pressure Side is Too Low
High-pressure Side is Too Low and Low-pressure Side is Too High
Gauge indication Refrigerant cycleProbable causeCorrective action
Both high- and low-pressure sides
are too high. Pressure is reduced soon af-
ter water is splashed on con-
denser.
Excessive refrigerant charge in
refrigeration cycle
Reduce refrigerant until speci-
fied pressure is obtained.
Air suction by cooling fan is in-
sufficient. Insufficient condenser cooling
performance
↓
1. Condenser fins are
clogged.
2. Improper fan rotation of cooling fan • Clean condenser.
• Check and repair cooling fan
if necessary.
• Low-pressure pipe is not cold.
• When compressor is stopped high-pressure val-
ue quickly drops by approx-
imately 196 kPa (2 kg/cm
2 ,
28 psi). It then decreases
gradually thereafter. Poor heat exchange in con-
denser
(After compressor operation
stops, high-pressure decreas-
es too slowly.)
↓
Air in refrigeration cycle
Evacuate and recharge system.
Engine tends to overheat. Engine cooling systems mal-
function. Check and repair engine cool-
ing system.
• An area of the low-pressure pipe is colder than areas
near the evaporator outlet.
• Plates are sometimes cov- ered with frost. • Excessive liquid refrigerant
on low-pressure side
• Excessive refrigerant dis-
charge flow
• Expansion valve is open a lit- tle compared with the speci-
fication.
↓
Improper expansion valve ad-
justment Replace expansion valve.
AC359A
Gauge indication
Refrigerant cycleProbable causeCorrective action
High-pressure side is too high and
low-pressure side is too low. Upper side of condenser and
high-pressure side are hot,
however, liquid tank is not so
hot.High-pressure tu
be or parts lo-
cated between compressor
and condenser are clogged or
crushed. • Check and repair or replace
malfunctioning parts.
• Check oil for contamination.
AC360A
Revision: March 2010 2008 QX56
INSUFFICIENT HEATINGHAC-117
< SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER]
C
D
E
F
G H
J
K L
M A
B
HAC
N
O P
INSUFFICIENT HEATING
Component Function CheckINFOID:0000000001679835
SYMPTOM: Insufficient heating
INSPECTION FLOW
1.CONFIRM SYMPTOM BY PERFORMING OPERAT IONAL CHECK - TEMPERATURE INCREASE
1. Press the AUTO switch.
2. Turn the temperature control dial (driver) clockwise until 32 °C (90 °F) is displayed.
3. Check for hot air at discharge air outlets.
Can this symptom be duplicated?
YES >> GO TO 2.
NO >> Perform complete system operational check. Refer to HAC-4, "
Operational Check (Front)".
2.CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
>> GO TO 3.
3.PERFORM SELF-DIAGNOSIS
Perform self-diagnosis. Refer to HAC-22, "
A/C Auto Amp. Self-Diagnosis".
Is the inspection results normal?
YES >> GO TO 4.
NO >> Refer to HAC-23, "
A/C System Self-Diagnosis Code Chart".
4.CHECK ENGINE COOLING SYSTEM
1. Check for proper engine coolant level. Refer to CO-10, "
Inspection".
2. Check hoses for leaks or kinks.
3. Check radiator cap. Refer to CO-10, "
Inspection".
4. Check for air in cooling system.
>> GO TO 5.
5.CHECK AIR MIX DOOR OPERATION
Check the operation of the air mix door.
Is the inspection result normal?
YES >> GO TO 6.
NO >> Check the air mix door motor circuit. Refer to HAC-31, "
Air Mix Door Motor Component Function
Check".
6.CHECK AIR DUCTS
Check for disconnected or leaking air ducts.
Is the inspection result normal?
YES >> GO TO 7.
NO >> Repair all disconnected or leaking air ducts.
7.CHECK HEATER HOSE TEMPERATURES
1. Start engine and warm it up to normal operating temperature.
2. Touch both the inlet and outlet heater hoses.
Is the inspection result normal?
YES >> Hot inlet hose and a warm outlet hose: GO TO 8.
NO >> • Inlet hose cold: GO TO 11. • Both hoses warm: GO TO 9.
8.CHECK ENGINE COOLANT SYSTEM
Check engine control temperature sensor. Refer to EC-126, "
Component Inspection".
Revision: March 2010 2008 QX56
HAC-118
< SYMPTOM DIAGNOSIS >[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT HEATING
Is the inspection result normal?
YES >> System OK.
NO >> Repair or replace as necessary. Retest.
9.CHECK HEATER HOSES
Check heater hoses for proper installation.
Is the inspection result normal?
YES >> System OK.
NO >> 1. Back flush heater core. 2. Drain the water from the system.
3. Refill system with new engine coolant. Refer to CO-11, "
Changing Engine Coolant".
4. GO TO 10 to retest.
10.CHECK HEATER HOSE TEMPERATURES
1. Start engine and warm it up to normal operating temperature.
2. Touch both the inlet and outlet heater hoses.
Is the inspection result normal?
YES >> System OK.
NO >> Replace heater core. Refer to VTL-19, "
Removal and Installation".
11 .CHECK WATER VALVE
Check the operation of the water valve. Refer to HAC-76, "
Water Valve Diagnosis Procedure".
Is the inspection result normal?
YES >> System OK.
NO >> Replace water valve.
Revision: March 2010 2008 QX56