Downloaded from www.Manualslib.com manuals search engine GWFLORID Maintenance Manual16
Air Conditioning System Structure and Parameters
ItemStructure and parameters
Structure typeVapor compression refrigeration, water warmer, and water heater
Performance parametersAir conditioner refrigerating capacity is 5 kW. Blower's air volume is 450 m3/h. Air
conditioner heating capacity is 4.5 kW.
Controls
Control panel knob, button, manual shift lever control, position gate and temperature
threshold cable drive, new damper micro-motor drive, able to select and adjust air
outlet position, heating/cooling mode, air inner/outer circulation mode and wind speed,
temperature, and more advanced selections and adjustables.
RefrigerantR134a, 510±10g
CompressorModel number: JSS-96TV4-4
CondenserAdvective and subcooling structure with flat tube thickness of 16 mm and dry reservoir
Φ34 mm × L280 mm.
Heating, Ventilating
and Air Conditioning
(HVAC)
Heating, Ventilating and Air Conditioning (HVAC): Of a three-box type consisting of
a layered evaporator, advective heater, H-shaped expansion valve, centrifugal blower,
and air outlet distributing box. Contains cooling, heating, defrosting and air freshening
functions, and operated by a link mechanism driving air valve.
Refrigeration line &
water heating tube
Refrigeration line: a compound structure using a rubber cooling pipe and an aluminum
pipe. Water heating pipe: molded rubber pipe.
SensorsEvaporator temperature sensor
Pressure switchHigh/Mid/Low three position pressure switch
Electrical System Structure and Parameters
ItemStructure and parameters
Power, start
up, and
electronic
charging
system
CircuitSingle wire system, voltage of DC12 V, negative ground
Battery12 V/60 Ah, maintenance-free battery
Starter1.2 kW
Alternator14 V/90 A
Lighting and
signaling
system
Headlight2 white (high beam 55 W, low beam 60 W) H4, height is electrically
adjustable.
Parking lamp2 front parking lamp: white, 5 W. 2 rear parking lamp: red, 5W
Turn signal lampAmber colored. 21W, 2 in the front and 21W, 2 in the back. Turn signal
lamps: 0.3W, 4 LED.
Fog lamp2 front fog lamps: 55W. 2 rear fog lamps: 7.5 W
Brake lamp2 red 21 W. high mounted brake lamps 3 W
License plate lamp2 white 5 W
Reverse lamp2 white 21 W
Hazard warning signal
lampAll turn signal lamps and switch controls
Rear reflectorsRed and non-triangular, inside the rear combination lamps.
Front reading lamp &
interior dome lamp
Front reading lamp: one white 10 W or one white 10 W, two 5 W (with
sunroof).
Interior dome lamp: White, 10 W.
Cigarette lighter
lightingBlue, 3 W, one
Downloaded from www.Manualslib.com manuals search engine 201Electrical Accessories
1. This player is used on vehicles with a 12 V battery and negative ground. If this player is to be installed
on a vehicle with a 24 V battery, please install voltage reduction equipment.
2. To avoid short circuiting the electrical system, cut off the battery negative end's connection wire before
installation.
3. Please arrange the connection wires at fixed locations, as to make sure they will not make contact
with any portable parts, such as the parking brake control mechanism assembly, gear lever, the seat's
fixed track, and so on. Please do not arrange the wires in a heat source area, like near the discharge
outlet of the heater, etc. Otherwise the heat source will cause the insulating layer to melt or wear out,
and then lead to a short circuit between the connection wire and the veh\
icle body.
4. Do not put the power cord through the mounting hole into the engine box and then connect it to the
battery. Otherwise it might damage the power cord and then lead to a short circuit between the power
cord and the vehicle body.
5. When changing the fuse, please use the specified 15 A fuse. Fuses with an unmatched size will lead
to abnormal operation, and even damage the player or cause a fire hazard\
.
6. Please do not share the player's power supply with other equipment, otherwise it might lead to a
malfunction due to overloading.
7. Please wrap up the exposed places of the wire with insulating cement to \
avoid short circuiting.
8. Bind up all the connection wires well to avoid any connecting term inal touching the player or other
mental parts of the vehicle body and leading to a short circuit.
9. When switching the player's power on, the external connection amplifier's controlling signal will output
through the lead wire P.CONT. If the player is connected with an external connection amplifier, please
do not connect the lead wire P.CONT to the amplifier's supply terminal, otherwise it will cause a
malfunction.
10. The player's outputting terminal must not be grounded, otherwise the amplifier may burn out. Please
do not use a 3-wire type speaker system which shares the ground cable. Please do not connect the
speaker wire to the vehicle body.
11. The maximum rated power of the speaker connected to this player is 50 W , resistance value is 4 Ω.
Control wire connection areas of importance
Downloaded from www.Manualslib.com manuals search engine GWFLORID Maintenance Manual206
FailureSymptoms Cause analysis
Heating sys-
tem
No or insuffi-
cient heating
Air conditioner blower malfunction
Blower relay damaged
Hot air duct blockage
Cooling water pipe blockage
Temperature change throttle actuator damaged
Coolant insufficient
Blower does
not work
Fuse blown or ill switch contact
Blower motor burnt out
Blower's high speed relay broken
Speed adjustive resistance damaged
Open circuit
Water leakageHeater water pipe degradation, poor connection
Over heatedFan's speed adjustive resistance damaged
Temperature change throttle actuator damaged
Defroster’s hot
air insufficient
Mode cable damaged
Vent is not in place
Air outlet blockage
Insufficient heating
Air duct mounting
Open circuit
Troubleshooting (Continued)