AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-37V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF093
PRESENT
OR
STOREDMANUAL SEQUENTIAL CONTROLS CIRCUIT
1.DEF: Inconsistency of the signal
CC.0: Short circuit to earth
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears during a road test when selecting position M with the lever
(one- touch control).
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance of the following connections:
●connection code 5FM, between components 119 and 129,
●connection code 5H, between components 119 and 129,
●connection code 5DU, between components 119 and 129,
●connection code N, between components 107 and 129.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF093/DP0TA2005_V18_DF093
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-38V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF095
PRESENT
OR
STOREDSELECTOR LEVER LOCK ELECTROMAGNET CIRCUIT
CO: Open circuit
CC.1: Short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears when the gear lever is in position P.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Check the cleanliness and condition of the gear lever lock electromagnet connections.
With the ignition on, check for + 12 V, on connection AP43 of component 129.
–Disconnect the battery.
–Check fuse 5F in the Protection and Switching Unit, as well as the cleanliness and condition of the connections.
–Disconnect connector PPH2 in the Protection and Switching Unit.
–Check the cleanliness and condition of the connectors.
Use the Universal bornier Elé. 1681. To check the insulation to earth and the continuity of the following
connection:
●connection code AP43, between components 129 and 1337.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If, with the ignition on, + 12 V is not present on connection AP43 of component 129, run fault finding on the
Protection and Switching Unit.
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the universal bornier Elé. 1681. Check the insulation and continuity of the following connection:
●connection code 5DU, between components 119 and 129.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Measure the resistance of component 129 between the following connections:
●connection code 5DU,
●connection code AP43.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
The resistance should be 40 Ω ± 4 Ω at a temperature of approximately 23˚C.
Otherwise replace the gear lever lock electromagnet.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF095/DP0TA2005_V18_DF095
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-42V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF112
PRESENT
OR
STOREDEVS6 SEQUENCE SOLENOID VALVE CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
NOTESDeal with fault DF012 Solenoid valves supply first if it is present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●connection code 5AU, between components 119 and 754,
●connection code 5DM, between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●connection code 5DM,
●connection code 5AU.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Replace the solenoid valve or the electric/hydraulic interface wiring harness if the resistance is not 40 Ω ± 2
at 23˚C.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF112/DP0TA2005_V18_DF112
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-46V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF145
PRESENT
OR
STOREDINVALID PEDAL POSITION MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESConditions for applying the fault finding procedure to stored faults:
If the fault appears following a road test during which the quality of the gear changes
deteriorates.
Disconnect the battery.
Disconnect the gearbox computer. Check the cleanliness and condition of the connectors.
Disconnect the engine management computer. Check the cleanliness and condition of the connectors.
If the fault is still present, run fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
Repair if necessary.
Run a multiplex network test (see 88B, Multiplex).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF145/DP0TA2005_V18_DF145
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-71V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF244
PRESENT
OR
STOREDTURBINE SPEED SENSOR SIGNAL
1.DEF: Communication disrupted
2.DEF: No signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears when the engine is running and the gear lever is at P.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connections:
●connection code 5DA, between components 119 and 1017,
●connection code 5DB, between components 119 and 1017.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 1017 between the following connections:
●connection code 5DA,
●connection code 5DB.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Replace the sensor or the wiring harness if the resistance is not: 300 Ω ± 40.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF244/DP0TA2005_V18_DF244
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-90V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET003
BRAKE LIGHT SWITCH (OPENING)
NOTESThere must be no present or stored faults.
The status displays "OPEN" with the pedal released and changes to "CLOSED" with the brake pedal depressed.
Check the cleanliness and the condition of the brake light switch connections.
Check the position, setting and correct operation of the brake light switch. (Watch out for the floor carpet which can
jam the switch.)
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference resistance
on the following connection:
●connection code 5A, between components 119 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the correct status is not displayed, replace the switch.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET003/DP0TA2005_V18_ET003
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-91V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET004
STOP LIGHT SWITCH (CLOSURE)
NOTESThere must be no present or stored faults.
The status displays "CLOSED" with the pedal released and changes to "OPEN" with the brake pedal depressed.
Check the cleanliness and the condition of the brake light switch connections.
Check the position, setting and correct operation of the brake light switch. (Watch out for the floor carpet which
can jam the switch.)
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference
resistance on the following connection:
●connection code 5A, between components 119 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the correct status is not displayed, replace the switch.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET004/DP0TA2005_V18_ET004
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-93V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET012
GEAR LEVER POSITION
NOTESThere must be no present or stored faults.
LEVER POSITION
"P"-"R"-"N"-"D"
Check the cleanliness, condition and mounting of the automatic transmission
multifunction switch.
Check the control setting (see MR 370 Mechanical, 23A Automatic transmission,
Multifunction switch, Adjustment (for Mégane II and Scénic II)).
Disconnect the battery.
Disconnect the modular connector and check the cleanliness and condition of the
connector A connections.
If the connector is faulty and there is a repair method (see Technical Note 6015A,
Repairing electrical wiring, Wiring: Precautions for repair), repair the connector,
otherwise replace the wiring.
Check the continuity of the following connections:
Lever in position "P"
●connection codes 5DG and 5DK between components 119 and 485.
Lever in position "R"
●connection codes 5DG, 5DH, DJ and 5DK, between components 119 and 485.
Lever in position "N"
●connection code 5DH between components 119 and 485.
Lever in position "D"
●connection code 5DJ between components 119 and 485.
Check the insulation against + 12 V of the following connections:
Lever in position "P"
●connection codes 5DH, 5DJ and 5DK, between components 119 and 485.
Lever in position "N"
●connection codes 5DG, 5DJ and 5DK, between components 119 and 485.
Lever in position "D"
●connection codes 5DG, 5DH and 5DK, between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure
(see Technical Note 6015A, Electrical wiring repair, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET012/DP0TA2005_V18_ET012