AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-43V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF113
PRESENT
OR
STOREDCONVERTER LOCK-UP SERVO CONTROL
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
If the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit.
–DF016 Lock-up solenoid valve circuit.
–DF177 Automatic transmission overheating.
–DF226 Automatic transmission internal pressure.
–DF244 Turbine speed sensor signal
Use the Mégane II or Scénic II wiring diagram Technical Note.
Check the quality and level of the gearbox oil (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scenic II)).
Check that the gearbox is not leaking oil.
Carry out the converter setting point test.
To locate the cap position, consult MR 364, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Mégane II) and MR 370, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Scénic II).
Check the oil pressure with the engine switched off using PR003 Oil pressure: if the pressure is greater than
0.2 bars, replace the pressure sensor.
Warm engine with gearbox oil temperature between 65 and 90˚C.
Measure the line pressure under the 3 following conditions:
IMPORTANT
The vehicle must be stationary: handbrake on and brake pedal depressed, no accessories operating
(e.g.: air conditioning)
1engine speed idling:
Shift the gear lever to R, N and D, the pressure reading must be greater than 2.5 bar.
2engine speed at 1200 rpm:
–gear lever in R position, the pressure reading must be greater than 4 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 5.5 bar.
3engine speed at 2200 rpm:
–gear lever in R position, the pressure reading must be greater than 11 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 11 bar.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF113/DP0TA2005_V18_DF113
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-45V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF131
PRESENT
OR
STOREDSLIPPAGE
1.DEF: Permanent low level
NOTESDeal with all other faults first.
Conditions for applying the fault finding procedure to stored faults:
Safe mode is triggered after a fault, not by the driver.
In particular, check that there are no faults on:
–the turbine speed sensor, DF244 Turbine speed sensor signal.
–the vehicle speed signal, DF230 Invalid vehicle speed multiplex signal.
Check that PR003 “Oil pressure” equals 21 bar. (forced setpoint)
Possible defective components:
Slave cylinder (brakes, clutch) or computer.
Then check cleanliness and condition of the gearbox oil.
If the fault is still present, contact Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF131/DP0TA2005_V18_DF131
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-46V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF145
PRESENT
OR
STOREDINVALID PEDAL POSITION MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESConditions for applying the fault finding procedure to stored faults:
If the fault appears following a road test during which the quality of the gear changes
deteriorates.
Disconnect the battery.
Disconnect the gearbox computer. Check the cleanliness and condition of the connectors.
Disconnect the engine management computer. Check the cleanliness and condition of the connectors.
If the fault is still present, run fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
Repair if necessary.
Run a multiplex network test (see 88B, Multiplex).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF145/DP0TA2005_V18_DF145
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-48V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF177
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION OVERHEATING
NOTESIf the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit.
–DF016 Lock-up solenoid valve circuit.
–DF017 Exchanger flow solenoid valve circuit.
–DF023 Gearbox oil temperature sensor circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF131 Slipping.
–DF226 Automatic transmission internal pressure.
–DF237 Invalid coolant temperature signal.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scenic II)).
Check that the water-oil exchanger is not blocked.
Measure the resistance of component 754 between the following connections:
●connection code 5BC,
●connection code 5BB.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
The resistance should be between:
2660 Ω < R < 2360 Ω at 20˚C and 327 Ω < R < 290 Ω at 80˚C.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF177/DP0TA2005_V18_DF177
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-52V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF226
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION INTERNAL PRESSURE
NOTESIf the following faults are present or stored, deal with them first:
–DF003 Sensor feeds.
–DF005 Oil pressure sensor circuit.
–DF023 Gearbox oil temperature sensor circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF244 Turbine speed sensor signal
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Check the gearbox oil grade and level (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scénic II)).
Check that the gearbox is not leaking oil
To locate the cap position, consult MR 364, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Mégane II) and MR 370, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Scénic II)).
Check the oil pressure with the engine switched off using PR003 Oil pressure: if the pressure is greater than
0.2 bars, replace the pressure sensor.
●Warm engine with gearbox oil temperature between 65 and 90˚C.
●Measure the line pressure under the 3 following conditions:
IMPORTANT
The vehicle must be stationary: handbrake on and brake pedal depressed, no accessories operating (e.g.:
air conditioning)
1engine speed idling:
Shift the gear lever to R, N and D, the pressure reading must be greater than 2.5 bar.
2engine speed at 1200 rpm:
–gear lever in R position, the pressure reading must be greater than 4 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 5.5 bar.
3engine speed at 2200 rpm:
–gear lever in R position, the pressure reading must be greater than 11 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 11 bar.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF226/DP0TA2005_V18_DF226
Fault finding - Conformity check23A
23A - 73V5 MR-372-J84-23A100$464.mif
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Conformity check
MAIN SCREEN
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Engine speedPR006:Engine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
2Turbine speedPR007:Turbine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
3Power supplyPR008:Computer feed
voltage10 V < X < 13 VIn the event of a
fault, consult the
interpretation of this
parameter.
4Gearbox oil
temperaturePR004:Gearbox oil
temperature- 40 ˚C < X < 140 ˚CIn the event of a
fault, consult the
interpretation of this
parameter.
5Coolant
temperaturePR001:Coolant
temperature- 40 ˚C < X < 120 ˚CIn the event of a
fault, consult the
interpretation of this
parameter.
6Oil pressurePR003:Oil pressureX < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
DP0TA2005_V14_CCONF/DP0TA2005_V18_CCONF
MR-372-J84-23A100$464.mif
AUTOMATIC TRANSMISSION
Fault finding - Conformity check
23A
23A - 79V5 MR-372-J84-23A100$464.mif
SIEMENS TA2005
Vdiag No.: 14-18
SUB-FUNCTION: PRESSURE CONTROL
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Gear engagedET013:Gear engagedR for reverse.
1P for 1
st locked.
2P for 2nd locked.
3P for 3rd locked.
4P for 4th locked.
1G for 1st slipping.
2G for 2nd slipping.
3G for 3rd slipping.
4G for 4th slipping.
1 for 1st unlocked.
2 for 2nd unlocked.
3 for 3rd unlocked.
4 for 4th unlocked.In the event of a
fault, refer to the
interpretation of this
status.
2Engine speedPR006:Engine speed0 rpmIn the event of a
fault, refer to the
interpretation of
fault DF236 "Invalid
engine speed
multiplex signal".
3Oil pressurePR003:Oil pressureX < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
4Gearbox oil
pressure sensor
voltagePR118:Gearbox oil
pressure sensor
voltageX = 5 VIn the event of a
fault, consult the
interpretation of this
parameter.
5Reference
pressurePR138:Reference
pressure21 bar None.
AUTOMATIC TRANSMISSION
Fault finding - Conformity check
23A
23A - 80V5 MR-372-J84-23A100$464.mif
SIEMENS TA2005
Vdiag No.: 14-18
SUB-FUNCTION: PRESSURE REGULATION (CONTINUED)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
6Difference
between
reference
pressure and oil
pressurePR146:Difference
between
reference and oil
pressureX = PR138 - PR003 None.
7Gearbox oil
temperaturePR004:Gearbox oil
temperature- 40 ˚C < X < 140 ˚CIf there is a fault,
refer to the
interpretation of this
parameter.
8Sequential
actuator controlAC024:Sequential
actuator controlCommand used to actuate
all the solenoid valves.In the event of a
fault, refer to the
interpretation of this
command.