Page 639 of 2896

BL-150
INTELLIGENT KEY SYSTEM
Revision: June 20062007 Versa
2. CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Disconnect stop lamp switch connector.
2. Check voltage between stop lamp switch harness connector
E13 terminal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between stop lamp switch
power supply circuit and fuse.
3. CHECK STOP LAMP SWITCH OPERATION
Check continuity between stop lamp switch terminals 1 and 2.
OK or NG
OK >> GO TO 4.
NG >> Replace stop lamp switch.
4. CHECK STOP LAMP SWITCH CIRCUIT
1. Check continuity between Intelligent Key unit harness connector
(A) M52 terminal 26 and stop lamp switch harness connector (B)
E13 terminal 2.
2. Check continuity between Intelligent Key unit harness connector
M52 terminal 26 and ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Repair or replace harness.1 - Ground : Battery voltage
WIIA1208E
Component Terminals Condition Continuity
Stop lamp
switch12Brake pedal depressed Yes
Brake pedal not depressed No
WIIA1209E
26 - 2 : Continuity should exist.
26 - Ground : Continuity should not exist.
WIIA1210E
Page 640 of 2896

INTELLIGENT KEY SYSTEM
BL-151
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Check CVT Device (Park Position Switch) CheckEIS009DA
1. CHECK CVT DEVICE (PARK POSITION SWITCH) INPUT SIGNAL
1. Turn ignition switch OFF.
2. While pressing the ignition knob switch, check voltage between Intelligent Key unit harness connector
M52 terminal 10 and ground.
OK or NG
OK >> Replace Intelligent Key unit. Refer to BL-160, "Removal
and Installation of Intelligent Key Unit" .
NG >> GO TO 2.
2. CHECK CVT DEVICE (PARK POSITION SWITCH)
1. Disconnect CVT device (park position switch) connector.
2. Check continuity between CVT device (park position switch) terminals 6 and 8.
OK or NG
OK >> GO TO 3.
NG >> Replace CVT device (park position switch).
3. CHECK PARK POSITION SWITCH GROUND CIRCUIT
Check continuity between CVT device (park position switch) harness
connector M38 terminal 6 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M52 10 GroundSelector lever is in "P" position 0
Other than above Battery voltage
WIIA1258E
Component Terminals Condition Continuity
CVT device
(park position
switch)68Selector lever is in "P" position Yes
Other than above No
WIIA1259E
6 – Ground : Continuity should exist.
WIIA1260E
Page 641 of 2896

BL-152
INTELLIGENT KEY SYSTEM
Revision: June 20062007 Versa
4. CHECK PARK POSITION SWITCH CIRCUIT
1. Disconnect Intelligent Key unit connector.
2. Check continuity between Intelligent Key unit harness connector
(A) M52 terminal 10 and CVT device (park position switch) har-
ness connector (B) M38 terminal 8.
3. Check continuity between Intelligent Key unit harness connector
(A) M52 terminal 10 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness.
5. CHECK INTELLIGENT KEY OUTPUT SIGNAL
1. Connect Intelligent Key unit connector and CVT device (park position switch) connector.
2. Check voltage between Intelligent Key unit connector M52 terminal 10 and ground.
OK or NG
OK >> CVT device (park position switch) circuit is OK.
NG >> Replace Intelligent Key unit. Refer to BL-160, "
Removal
and Installation of Intelligent Key Unit" . 10 – 8 : Continuity should exist.
10 – Ground : Continuity should not exist.
WIIA1261E
ConnectorTerminal
ConditionVoltage (V)
(Approx.)
(+) (-)
M52 10 GroundSelector lever is in “P” position 0
Other than above Battery voltage
WIIA1258E
Page 646 of 2896

INTELLIGENT KEY SYSTEM
BL-157
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
2. CHECK OTHER WARNING CHIME OPERATION
Check other warning chime operation using combination meter.
OK or NG
OK >> INSPECTION END
NG >> GO TO DI-47, "
WARNING CHIME" .
Hazard Function CheckEIS0092S
1. CHECK HAZARD WARNING LAMP
Do hazard warning lamps flash with hazard switch?
YES or NO
YES >> Hazard warning lamp circuit is OK.
NO >> Check hazard circuit. Refer to LT- 5 1 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Horn Function CheckEIS0092T
First perform the “SELF-DIAG RESULTS” of “BCM” with CONSULT-II, then perform the trouble diagno-
sis of malfunction system indicated in “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-18, "
CAN Com-
munication Inspection Using CONSULT-II (Self-Diagnosis)".
1. CHECK HORN OPERATION
Check if horn sounds with horn switch.
Does horn operate?
Yes >> GO TO 2.
No >> Check horn circuit. Refer to WW-46, "
HORN" .
2. CHECK IPDM E/R INPUT SIGNAL
Check voltage between IPDM E/R connector and ground.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-29, "Removal and
Installation of IPDM E/R" .
NG >> GO TO 3.Does warning chime in combination meter sound?
Te r m i n a l s
Voltage (V)
(Approx.) (+)
(–)
IPDM E/R
connectorTe r m i n a l
E46 45 Ground Battery voltage
WIIA1251E
Page 648 of 2896

INTELLIGENT KEY SYSTEM
BL-159
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Intelligent Key Battery ReplacementEIS0092W
DISASSEMBLY AND ASSEMBLY OF INTELLIGENT KEY
1. Release the lock knob at the back of the Intelligent Key and remove the mechanical key.
2. Insert a flat-blade screwdriver (A) wrapped with a cloth into the
slit of the corner and twist it to separate the upper part from the
lower part.
CAUTION:
Be careful not to touch the circuit board or battery termi-
nal.
The key fob is water-resistant. However, if it does get wet,
immediately wipe it dry.
3. Replace the battery with new one.
4. Align the tips of the upper and lower parts, and then push them
together until it is securely closed.
CAUTION:
When replacing battery, be sure to keep dirt, grease, and
other foreign materials off the electrode contact area.
After replacing the battery, check to make sure all Intelli-
gent Key functions work normally.
INTELLIGENT KEY BATTERY INSPECTION
Check by connecting a resistance (approximately 300Ω) so that the
current value becomes about 10 mA.
Remote Keyless Entry FunctionEIS0 09 DF
Check keyfob function using Remote Keyless Entry Tester J-43241.
PIIB6221E
PIIB6222E
Standard : Approx. 2.5 - 3.0V
OCC0607D
LEL946A
Page 670 of 2896

BACK DOOR LOCK
BL-181
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Check Back Door Opener Switch Circuit (Without Intelligent Key or Power Win-
dows)
EIS009DS
1. CHECK BACK DOOR OPENER SWITCH SIGNAL 1
With CONSULT-II
1. Insure front door lock knob LH is turned to the UNLOCK position.
2. Check back door opener switch (“TRNK OPNR SW”) in “DATA MONITOR” mode with CONSULT-II.
Without CONSULT-II
1. Insure front door lock knob LH is turned to the UNLOCK position.
2. Check voltage between BCM connector M18 terminal 30 and ground.
OK or NG
OK >> Back door opener switch is OK.
NG >> GO TO 2.
2. CHECK BACK DOOR OPENER SWITCH CIRCUIT 1
1. Turn ignition switch OFF.
2. Disconnect BCM and back door opener switch connector.
3. Check continuity between BCM connector (A) M18 terminal 30 and back door opener switch connector
(B) terminal 1.
4. Check continuity between BCM connector (A) M18 terminal 30
and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Test item Condition
TRNK OPNR SWBack door opener switch is pushed: ON
Back door opener switch is released: OFF
WIIA1270E
Te r m i n a l s
Door conditionVoltage (V)
(Approx.) (+)
(–)
BCM
connectorTe r m i n a l
M18 30 GroundBack door
opener switchPushed 0
Released Battery voltage
PIIB6468E
AB
Continuity
BCM connector TerminalBack door opener
switch connectorTe r m i n a l
M18 30 D408 1 Yes
A
GroundContinuity
BCM connector Terminal
M18 30 No
PIIB6469E
Page 673 of 2896

BL-184
BACK DOOR LOCK
Revision: June 20062007 Versa
Check Back Door Opener Switch Circuit (Without Intelligent Key, With Power
Windows)
EIS009DV
1. CHECK BACK DOOR OPENER SWITCH SIGNAL 1
With CONSULT-II
1. Insure front door lock knob RH is turned to the UNLOCK position.
2. Check back door opener switch (“TRNK OPNR SW”) in “DATA MONITOR” mode with CONSULT-II.
Without CONSULT-II
1. Insure front door lock knob RH is turned to the UNLOCK position.
2. Check voltage between BCM connector M18 terminal 30 and ground.
OK or NG
OK >> Back door opener switch is OK.
NG >> GO TO 2.
2. CHECK BACK DOOR OPENER SWITCH CIRCUIT 1
1. Turn ignition switch OFF.
2. Disconnect BCM and back door opener switch connector.
3. Check continuity between BCM connector (A) M18 terminal 30 and back door opener switch connector
(B) terminal 1.
4. Check continuity between BCM connector (A) M18 terminal 30
and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Test item Condition
TRNK OPNR SWBack door opener switch is pushed: ON
Back door opener switch is released: OFF
WIIA1270E
Te r m i n a l s
Door conditionVoltage (V)
(Approx.) (+)
(–)
BCM
connectorTerminal
M18 30 GroundBack door
opener switchPushed 0
Released Battery voltage
PIIB6468E
AB
Continuity
BCM connector TerminalBack door opener
switch connectorTe r m i n a l
M18 30 D408 1 Yes
A
GroundContinuity
BCM connector Terminal
M18 30 No
PIIB6469E
Page 696 of 2896

VEHICLE SECURITY (THEFT WARNING) SYSTEM
BL-207
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Diagnostic Procedure 1EIS009B6
1-1 DOOR SWITCH CHECK
1. CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT-II
Check door switches ("DOOR SW-DR", "DOOR SW-AS", "DOOR SW-RL", "DOOR SW-RR", "BACK DOOR
SW") in DATA MONITOR mode with CONSULT–II. Refer to BL-37, "
DATA MONITOR" .
When doors are open:
When doors are closed:
Without CONSULT-II
Check voltage between BCM connector M18 or M19 terminals 12, 13, 43, 47, 48 and ground.
OK or NG
OK1 >> Door switch circuit is OK (without Intelligent Key).
OK2 >> GO TO 6 (with Intelligent Key).
NG >> GO TO 2.DOOR SW-DR : ON
DOOR SW-AS : ON
DOOR SW-RL : ON
DOOR SW-RR : ON
BACK DOOR SW : ON
DOOR SW-DR : OFF
DOOR SW-AS : OFF
DOOR SW-RL : OFF
DOOR SW-RR : OFF
BACK DOOR SW : OFF
LIIA0665E
Connector ItemTerminals
ConditionVoltage (V)
(Approx.)
( + ) ( – )
M18Front door
switch RH12
GroundOpen
↓
Closed0
↓
Battery voltage Rear door
switch RH13
M19Back door
switch43
Front door
switch LH47
Rear door
switch LH48
LIIA1041E