WATER INLET AND THERMOSTAT ASSEMBLY
CO-27
C
D
E
F
G
H
I
J
K
L
MA
CO
Revision: 2006 November2007 350Z
2. Check valve operation.
If the malfunctioning condition, when valve seating at ordinary
room temperature, or measured values are out of the standard,
replace water inlet and thermostat assembly.
INSTALLATION
Note the following, and install in the reverse order of removal.
Be careful not to spill engine coolant over engine room. Use rag to absorb engine coolant.
INSPECTION AFTER INSTALLATION
Check for leaks of engine coolant using radiator cap tester adapter (commercial service tool) and radiator
cap tester (commercial service tool). Refer to CO-10, "
LEAK CHECK" .
Start and warm up engine. Visually make sure that there is no leaks of engine coolant.
Thermostat Standard
Valve opening temperature 82°C (180°F)
Maximum valve lift 9.0 mm / 95°C (0.354 in / 203°F)
Valve closing temperature 77°C (171°F)
SLC949A