Page 118 of 1575
10.Remove the upper oil pan, using the SST(09215- 3C000)(A).
Be careful not to damage the contact surfaces of upper oil pan and lower oil pan.
11. Remove the oil pump case(A).
12.After removing the plug(A), remove the relief spring(B) and the velief plunger(C).
REPLACEMENT
OIL AND FILTER
a.Prolonged and repeated contact with mineral oil will result in the removal of natural fats from the skin, leading
to dryness, irritation and dermatitis. In addition, used engine oil contains potentially harmful contaminants
which may cause skin cancer.
b. Wear protective clothing and gloves in order to minimize the length and frequency of contact of your skin to
used oil. Wash your skin thoroughly with soap and water, or use water- less hand cleaner, to remove any used
engine oil. Do not use gasoline, thinners, or solvents.
Page 731 of 1575

2007 > 2.7L V6 GASOLINE >
INSPECTION
OPERATION TEST
Fuel-fired heater operation test by force using Hi-Scan
1. Start the engine.
2. Connect the Hi - Scan to the vehicle.
3. Select "SORENTO" and then select "FUEL FIRED HEATER".
4. Select "04. ACTUATION TEST" mode.
5. Select "PREFILLING + HEATING" to conduct the performance test after replacing the fuel fired heater system.
Fuel supply and heating will be initiated if the "F1 key STRT" is pressed.
However, a repair or replacement of the components related to the fuel line system in the fuel- fired heater were not
done, operate the component by force after selecting the appropriate item from the menu screen.
Do not operate the system by force with selecting the “ PREFILLING + HEATING ” option if no repair for the
fuel line relating components has been done.
This means the fuel is in the fuel line.If an excessive fuel is supplied, it may cause smoke and abnormal
"Banging" noise when the fuel is burned.
If the "F2 KEY STOP" is pressed, operation test is stopped.
For self - diagnosis test and sensors outputs during compulsory operation test, press "ESC KEY".
When a self - diagnosis test is completed, disconnect the self - diagnosis connector or press "F2 KEY STOP"
from the "PREFILLING + HEATING" menu to stop the compulsory operation.
In case of selecting the individual part (ex. Combustion air fan, water pump, ), press "ESC KEY" to stop the
test.
In case of selecting the "PREFILLING + HEATING" option, about 2 minutes are required to conduct cleaning
process after pressing the "F2 KEY STOP".
It is a normal process to burn the fuel left in the fuel line.
6. To conduct self diagnosis test, press "ESC" and then "01. DIAGNOSTIC TROUBLE CODES" option.
7.Select "02. CURRENT DATA" to view the current status of the components.
Page 1445 of 1575
2007 > 2.7L V6 GASOLINE >
INSPECTION
1.With the washer motor connected to the reservoir tank, fill the reservoir tank with water.
2. Remove the front bumper. (Refer to the Body group - Front bumper)
3. Connect positive (+) and negative ( - ) battery cables to terminals 3 and 1 respectively to see that the washer motor
runs and water is pumped.
4. Check that the motor operates normally.
Replace the motor if it operates abnormally.