Page 2654 of 4647
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1125
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Wiring DiagramNBS005HO
TBWT1539E
Page 2656 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1127
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition s INFINITI M35 2007 Factory Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1127
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition s](/manual-img/42/57024/w960_57024-2655.png)
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1127
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister vent control valve (1) harness con-
nector.
–Illustration shows the view from under the vehicle.
–: Vehicle front
–EVAP canister (2)
–EVAP control system pressure sensor (3)
3. Turn ignition switch ON.
4. Check voltage between EVAP canister vent control valve termi-
nal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E106, B4
Harness connectors B66, B436
Harness connectors B469, B171
IPDM E/R harness connector E7
Harness for open or short between EVAP canister vent control valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 117 and EVAP canister vent control valve terminal 2.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
PBIB2702E
Voltage: Battery voltage
PBIB0152E
Continuity should exist.
Page 2661 of 4647
EC-1132
[VK45DE]
DTC P0448 EVAP CANISTER VENT CONTROL VALVE
Revision: 2007 April2007 M35/M45
Wiring DiagramNBS005HV
TBWT1539E
Page 2667 of 4647
![INFINITI M35 2007 Factory Service Manual EC-1138
[VK45DE]
DTC P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
Revision: 2007 April2007 M35/M45
2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
1. Disconnect EVAP control system press INFINITI M35 2007 Factory Service Manual EC-1138
[VK45DE]
DTC P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
Revision: 2007 April2007 M35/M45
2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
1. Disconnect EVAP control system press](/manual-img/42/57024/w960_57024-2666.png)
EC-1138
[VK45DE]
DTC P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
Revision: 2007 April2007 M35/M45
2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
1. Disconnect EVAP control system pressure sensor (3) harness
connector.
–Illustration shows the view from under the vehicle.
–: Vehicle front
–EVAP canister vent control valve (1)
–EVAP canister (2)
2. Check sensor harness connector for water.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness connector.
3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC-1138, "
Component Inspection" .
OK or NG
OK >> GO TO 4.
NG >> Replace EVAP control system pressure sensor.
4. CHECK INTERMITTENT INCIDENT
Refer to EC-857, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
For Wiring Diagram, refer to EC-1141, "
Wiring Diagram" .
>>INSPECTION END
Component InspectionNBS005I3
EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.
2. Install a vacuum pump to EVAP control system pressure sensor.
3. Turn ignition switch ON and check output voltage between ECM
terminal 32 and ground under the following conditions.
CAUTION:
Always calibrate the vacuum pump gauge when using it.
Do not apply vacuum below -93.3 kPa (-700 mmHg, -27.56
inHg) or pressure over 101.3 kPa (760 mmHg, 29.92 inHg).
4. If NG, replace EVAP control system pressure sensor.Water should not exist.
PBIB2702E
Applied vacuum kPa
(mmHg, inHg)Voltage V
Not applied 1.8 - 4.8
-26.7 (-200, -7.87) 2.1 to 2.5V lower than above value
PBIB1173E
Page 2670 of 4647
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-1141
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Wiring DiagramNBS005I8
TBWT1495E
Page 2672 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-1143
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn igni INFINITI M35 2007 Factory Service Manual DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-1143
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn igni](/manual-img/42/57024/w960_57024-2671.png)
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-1143
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between EVAP control system pressure sensor
terminal 3 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B171, B469
Harness connectors B418, M66
Harness connectors M72, F102
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND
SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal
67.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B171, B469
Harness connectors B418, M66
Harness connectors M72, F102
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors. Voltage: Approximately 5V
PBIB0138E
Continuity should exist.
Page 2673 of 4647
![INFINITI M35 2007 Factory Service Manual EC-1144
[VK45DE]
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
Revision: 2007 April2007 M35/M45
7. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Check harness c INFINITI M35 2007 Factory Service Manual EC-1144
[VK45DE]
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
Revision: 2007 April2007 M35/M45
7. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Check harness c](/manual-img/42/57024/w960_57024-2672.png)
EC-1144
[VK45DE]
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR
Revision: 2007 April2007 M35/M45
7. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal
2.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> GO TO 8.
8. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B171, B469
Harness connectors B418, M66
Harness connectors M72, F102
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC-1144, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace EVAP control system pressure sensor.
10. CHECK INTERMITTENT INCIDENT
Refer to EC-857, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionNBS005IA
EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.
2. Install a vacuum pump to EVAP control system pressure sensor.
3. Turn ignition switch ON and check output voltage between ECM
terminal 32 and ground under the following conditions.
CAUTION:
Always calibrate the vacuum pump gauge when using it.
Do not apply vacuum below -93.3 kPa (-700 mmHg, -27.56
inHg) or pressure over 101.3 kPa (760 mmHg, 29.92 inHg).
4. If NG, replace EVAP control system pressure sensor.Continuity should exist.
Applied vacuum kPa
(mmHg, inHg)Voltage V
Not applied 1.8 - 4.8
-26.7 (-200, -7.87) 2.1 to 2.5V lower than above value
PBIB1173E
Page 2676 of 4647
DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-1147
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Wiring DiagramNBS005IF
TBWT1495E