![INFINITI M35 2007 Factory Service Manual EC-490
[VQ35DE]
DTC P0643 SENSOR POWER SUPPLY
Revision: 2007 April2007 M35/M45
3. CHECK SENSOR POWER SUPPLY CIRCUITS
Check harness for short to power and short to ground, between the following termina INFINITI M35 2007 Factory Service Manual EC-490
[VQ35DE]
DTC P0643 SENSOR POWER SUPPLY
Revision: 2007 April2007 M35/M45
3. CHECK SENSOR POWER SUPPLY CIRCUITS
Check harness for short to power and short to ground, between the following termina](/manual-img/42/57024/w960_57024-2018.png)
EC-490
[VQ35DE]
DTC P0643 SENSOR POWER SUPPLY
Revision: 2007 April2007 M35/M45
3. CHECK SENSOR POWER SUPPLY CIRCUITS
Check harness for short to power and short to ground, between the following terminals.
OK or NG
OK >> GO TO 4.
NG >> Repair short to ground or short to power in harness or connectors.
4. CHECK COMPONENTS
Check the following.
EVAP control system pressure sensor (Refer to EC-436, "Component Inspection" .)
Refrigerant pressure sensor (Refer to AT C - 9 7 , "COMPONENT INSPECTION" .)
Battery current sensor (Refer to EC-529, "Component Inspection" .)
Power steering pressure sensor (Refer to EC-478, "Component Inspection" .)
OK or NG
OK >> GO TO 7.
NG >> Replace malfunctioning component.
5. CHECK APP SENSOR
Refer to EC-622, "
Component Inspection" .
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. REPLACE ACCELERATOR PEDAL ASSEMBLY
1. Replace accelerator pedal assembly.
2. Perform EC-86, "
Accelerator Pedal Released Position Learning" .
3. Perform EC-86, "
Throttle Valve Closed Position Learning" .
4. Perform EC-86, "
Idle Air Volume Learning" .
>>INSPECTION END
7. CHECK INTERMITTENT INCIDENT
Refer to EC-153, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
ECM terminal Sensor terminal Reference Wiring Diagram
90 APP sensor terminal 4EC-487
48 EVAP control system pressure sensor terminal 3EC-433
49Refrigerant pressure sensor terminal 1EC-705Battery current sensor terminal 1EC-526
68 PSP sensor terminal 1EC-475
Page 2022 of 4647
DTC P0850 PNP SWITCH
EC-493
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Wiring DiagramNBS0052R
TBWT0985E
Page 2023 of 4647
![INFINITI M35 2007 Factory Service Manual EC-494
[VQ35DE]
DTC P0850 PNP SWITCH
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminal INFINITI M35 2007 Factory Service Manual EC-494
[VQ35DE]
DTC P0850 PNP SWITCH
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminal](/manual-img/42/57024/w960_57024-2022.png)
EC-494
[VQ35DE]
DTC P0850 PNP SWITCH
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS0052S
1. CHECK DTC WITH TCM
Refer to AT- 4 0 , "
OBD-II Diagnostic Trouble Code (DTC)" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace.
2. CHECK STARTING SYSTEM
Turn ignition switch OFF, then turn it to START.
Does starter motor operate?
Ye s o r N o
Yes >> GO TO 3.
No >> Refer to SC-8, "
STARTING SYSTEM" .
3. CHECK PNP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-I
1. Turn ignition switch OFF.
2. Disconnect A/T assembly harness connector.
3. Disconnect “unified meter and A/C amp.” harness connector.
4. Check harness continuity between A/T assembly terminal 9 and “unified meter and A/C amp.” terminal 2.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M72, F102
Harness for open or short between A/T assembly and “unified meter and A/C amp.”
>> Repair open circuit or short to ground or short to power in harness or connectors.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
102 G PNP switch[Ignition switch: ON]
Selector lever: P or NApproximately 0V
[Ignition switch: ON]
Selector lever: Except aboveBATTERY VOLTAGE
(11 - 14V)
Continuity should exist.
Page 2024 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P0850 PNP SWITCH
EC-495
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
5. CHECK PNP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-II
1. Disconnect ECM harness connector.
2. C INFINITI M35 2007 Factory Service Manual DTC P0850 PNP SWITCH
EC-495
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
5. CHECK PNP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-II
1. Disconnect ECM harness connector.
2. C](/manual-img/42/57024/w960_57024-2023.png)
DTC P0850 PNP SWITCH
EC-495
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
5. CHECK PNP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-II
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 102 and “unified meter and A/C amp.” terminal 21.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 6.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
6. CHECK PNP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-III
1. Check harness continuity between A/T assembly terminal 9 and TCM terminal 8.
Refer to AT- 1 0 8 , "
DTC P0615 START SIGNAL CIRCUIT" .
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK INTERMITTENT INCIDENT
Refer to EC-153, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> GO TO 8.
NG >> Repair or replace.
8. REPLACE “UNIFIED METER AND A/C AMP.”
Refer to DI-28, "
UNIFIED METER AND A/C AMP" .
>>INSPECTION END Continuity should exist.
Continuity should exist.
Page 2031 of 4647
EC-502
[VQ35DE]
DTC P1217 ENGINE OVER TEMPERATURE
Revision: 2007 April2007 M35/M45
Wiring DiagramNBS00536
TBWT1533E
Page 2034 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P1217 ENGINE OVER TEMPERATURE
EC-505
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
5. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2. INFINITI M35 2007 Factory Service Manual DTC P1217 ENGINE OVER TEMPERATURE
EC-505
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
5. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2.](/manual-img/42/57024/w960_57024-2033.png)
DTC P1217 ENGINE OVER TEMPERATURE
EC-505
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
5. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2. Disconnect cooling fan control module (1) harness connector
E42.
–: Vehicle front
–Cooling fan motor-1 (2)
–Cooling fan motor-2 (3)
3. Turn ignition switch ON.
4. Check voltage between cooling fan control module terminal 3
and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 6.
NG >> GO TO 11.
6. CHECK COOLING FAN CONTROL MODULE GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check harness continuity between cooling fan control module terminal 1 and ground.
Refer to wiring diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 7.
NG >> Repair open circuit or short to power in harness or connectors.
7. CHECK IPDM E/R GROUND CIRCUIT
1. Disconnect IPDM E/R harness connector E8, E9.
2. Check harness continuity between IPDM E/R terminal 38, 51 and ground.
Refer to wiring diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to power in harness or connectors.
PBIB3352E
Voltage: Battery voltage
PBIA9509J
Continuity should exist.
Continuity should exist.
Page 2035 of 4647
![INFINITI M35 2007 Factory Service Manual EC-506
[VQ35DE]
DTC P1217 ENGINE OVER TEMPERATURE
Revision: 2007 April2007 M35/M45
8. CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
1. Check harness continuity between IPDM E/R terminal 59 and cooling fan INFINITI M35 2007 Factory Service Manual EC-506
[VQ35DE]
DTC P1217 ENGINE OVER TEMPERATURE
Revision: 2007 April2007 M35/M45
8. CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
1. Check harness continuity between IPDM E/R terminal 59 and cooling fan](/manual-img/42/57024/w960_57024-2034.png)
EC-506
[VQ35DE]
DTC P1217 ENGINE OVER TEMPERATURE
Revision: 2007 April2007 M35/M45
8. CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
1. Check harness continuity between IPDM E/R terminal 59 and cooling fan control module terminal 2.
Refer to wiring diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK COOLING FAN CONTROL MODULE OUTPUT SIGNAL CIRCUIT
1. Reconnect all harness connectors disconnected.
2. Disconnect cooling fan control module harness connectors E301, E303.
3. Turn ignition switch ON.
4. Check voltage between cooling fan control module terminals 4,
6 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 10.
NG >> Replace cooling fan control module.
10. CHECK COOLING FAN MOTORS -1 AND -2
Refer to EC-509, "
Component Inspection" .
OK or NG
OK >> GO TO 15.
NG >> Replace cooling fan motor.
11 . CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect cooling fan relay harness connector.
3. Turn ignition switch ON.
4. Check voltage between cooling fan relay terminals 1, 3 and
ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 13.
NG >> GO TO 12.Continuity should exist.
Voltage: Battery voltage
PBID0261J
Voltage: Battery voltage
PBIA9511J
Page 2036 of 4647
![INFINITI M35 2007 Factory Service Manual DTC P1217 ENGINE OVER TEMPERATURE
EC-507
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
12. DETECT MALFUNCTIONING PART
Check the following.
10A fuse
Fuse block (J/B) connector E INFINITI M35 2007 Factory Service Manual DTC P1217 ENGINE OVER TEMPERATURE
EC-507
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
12. DETECT MALFUNCTIONING PART
Check the following.
10A fuse
Fuse block (J/B) connector E](/manual-img/42/57024/w960_57024-2035.png)
DTC P1217 ENGINE OVER TEMPERATURE
EC-507
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
12. DETECT MALFUNCTIONING PART
Check the following.
10A fuse
Fuse block (J/B) connector E102
50A fusible link
Harness for open or short between cooling fan relay and fuse
Harness for open or short between cooling fan relay and battery
>> Repair open circuit or short to ground or short to power in harness or connectors.
13. CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT-III
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector E9.
3. Check harness continuity between the following;
Cooling fan relay terminal 2 and IPDM E/R terminal 56,
Cooling fan relay terminal 5 and cooling fan control module terminal 3.
Refer to wiring diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 14.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
14. CHECK COOLING FAN RELAY
Refer to EC-509, "
Component Inspection" .
OK or NG
OK >> GO TO 15.
NG >> Replace cooling fan relay.
15. CHECK INTERMITTENT INCIDENT
Perform EC-153, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace IPDM E/R. Refer to PG-18, "IPDM E/R (INTELLIGENT POWER DISTRIBUTION MOD-
ULE ENGINE ROOM)" .
NG >> Repair or replace harness connectors.
Main 12 Causes of OverheatingNBS00538
Continuity should exist.
Engine Step Inspection item Equipment Standard Reference page
OFF 1
Blocked radiator
Blocked condenser
Blocked radiator grille
Blocked bumper
Visual No blocking —
2
Coolant mixtureCoolant tester 50 - 50% coolant mixtureMA-13, "Anti-Freeze
Coolant Mixture Ratio"
3Coolant levelVisual Coolant up to MAX level
in reservoir tank and radi-
ator filler neckMA-15, "Changing
Engine Coolant"
4Radiator capPressure tester 59 - 98 kPa
(0.6 - 1.0 kg/cm2 , 9 - 14
psi) (Limit)CO-16, "
Checking Radia-
tor Cap"