Page 877 of 4366

REMOTE KEYLESS ENTRY SYSTEM BL-65
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
Work Support
*: Perform this mode always in the state of C mode. Refer to BL-56, "Hazard and Horn Reminder" .
HORN CHIRP SET*
*: Perform this mode always in the state of C mode. Refer to BL-56, "Hazard and Horn Reminder" .
This mode can be changed also on the display.
HAZARD LAMP BACK SET*
*: Perform this mode always in the state of C mode. Refer to BL-56, "Hazard and Horn Reminder" .
This mode can be changed also on the display. DOOR LOCK This test is able to check door lock actuator operation.
The all door lock actuator are locked when “ALL LOCK” on CONSULT-II screen is touched.
The all door lock actuator are unlocked when “ALL UNLOCK” on CONSULT-II screen is touched.
The door lock actuator (driver side) is unlocked when “DR UNLOCK” on CONSULT-II screen is
touched.
The all door lock actuator (except driver side) are unlocked when “OTHER UNLOCK” on CON-
SULT-II screen is touched.
TRUNK/BACK DOOR This is displayed even when it is not equipped. Test Item Description
Test Item Description
HORN CHIRP SET* Horn reminder mode can be changed in this mode. The horn reminder mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched.
HAZARD LAMP SET* Hazard reminder mode can be changed in this mode. The hazard reminder mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched.
MULTI ANSWER BACK SET Hazard and horn reminder mode can be changed in this mode. The hazard and horn
reminder mode will be changed when “CHANGE SETT” on CONSULT-II screen is touched.
AUTO LOCK SET Auto locking function mode can be changed in this mode. The function mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched.
PANIC ALRM SET Panic alarm operation mode can be changed in this mode. The operation mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched.
PW DOWN SET Keyless power window down (open) operation mode can be changed in this mode. The
operation mode will be changed when“CHANGE SETT” on CONSULT-II screen is touched.
Horn chirp function ON OFF
MODE1 MODE2 MODE3 MODE4
Hazard lamp operation mode Nothing Unlock only Lock only Lock and Unlock
Page 878 of 4366
BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
MULTI ANSWER BACK SET
AUTO LOCK SET
PANIC ALARM SET
PW DOWN SET
Work FlowNIS001MQ
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-55, "
System Description" .
3. Confirm that power door lock system operates normally. Refer to BL-21, "
POWER DOOR LOCK SYSTEM" .
4. Repair or replace any malfunctioning parts. Refer to BL-67, "
Trouble Diagnosis Chart by Symptom" .
5. INSPECTION END
MODE 1
(C mode) MODE 2
(S mode)
Key fob operation Lock Unlock Lock Unlock
Hazard warning lamp flash Twice Once Twice —
Horn sound Once — — —
MODE 1 MODE 2 MODE 3
Auto locking function 1 minutes Nothing 5 minutes
MODE 1 MODE 2 MODE 3
Key fob operation 0.5 seconds Nothing 1.5 seconds
MODE 1 MODE 2 MODE 3
Key fob operation 3 seconds Nothing 5 seconds
Page 879 of 4366

REMOTE KEYLESS ENTRY SYSTEM BL-67
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
Trouble Diagnosis Chart by SymptomNIS001MR
NOTE:
Always check the “Work Flow” before troubleshooting. Refer to BL-66, "Work Flow" .
Always check key fob battery before replacing key fob.
Symptom Diagnoses/service procedure Reference
page
All function of remote keyless entry system do not
operate. 1. Check key fob battery and function.
BL-69
2. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-81
3. Check remote keyless entry receiver.
BL-76
4. Replace BCM.BCS-14
The new ID of key fob cannot be entered. 1. Check key fob battery and function.
BL-69
2. Check key switch.BL-75
3. Check door switch.BL-71
4. Check ACC switch.BL-70
5. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-81
6. Replace BCM.
BCS-14
Door lock or unlock does not function with key fob.
(Power door lock system is “OK”.) 1. Check key fob battery and function.
BL-69
2. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-81
3. Replace BCM.
BCS-14
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of key fob. 1. Check hazard and horn reminder mode.*
*: Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder setting. BL-65
2. Check door switch.
BL-71
3. Replace BCM.BCS-14
Hazard reminder does not activate properly when
pressing lock or unlock button of key fob.
(Horn reminder is “OK”.) 1. Check hazard reminder mode.*
*: Hazard reminder mode can be changed.
First check the hazard reminder setting. BL-65
2. Check hazard function with hazard switch.
BL-80
3. Replace BCM.BCS-14
Horn reminder does not activate properly when
pressing lock button of key fob.
(Hazard reminder is “OK”.) 1. Check horn reminder mode.*
*: Horn reminder can be changed.
First check the horn chirp setting. BL-65
2. Check horn function.
BL-80
3. Check IPDM E/R operation.BL-79
4. Replace BCM.BCS-14
Page 880 of 4366

BL-68
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed. 1. Check panic alarm mode.*
*: Panic alarm mode can be changed.
First check the panic alarm setting. BL-65
2. Check key fob battery and function.
BL-69
3. Check headlamp function.BL-80
4. Check horn function.BL-80
5. Check IPDM E/R operation.BL-79
6. Check key switch.BL-75
7. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-81
8. Replace BCM.
BCS-14
Auto door lock operation does not activate properly.
(All other remote keyless entry system function is
OK.) 1. Check auto door lock operation mode.*
*: Auto door lock operation mode can be changed.
First check the auto door lock operation setting. BL-65
2. Replace BCM.
BCS-14
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry system function is
OK.) 1. Check power window down operation mode.*
*: Power window down operation mode can be changed.
First check the power window down setting. BL-65
2. Check power window function.
GW-15
3. Replace BCM.BCS-14
Map lamp and ignition keyhole illumination opera-
tion does not activate properly. 1. Check map lamp and ignition keyhole illumination operation.
BL-802. Check door switch.BL-71
3. Replace BCM.BCS-14
Symptom Diagnoses/service procedure Reference
page
Page 881 of 4366
REMOTE KEYLESS ENTRY SYSTEM BL-69
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
Check Key Fob Battery and FunctionNIS001MS
1. CHECK KEY FOB BATTERY
1. Remove key fob battery. Refer to BL-85, "
Key Fob Battery Replacement" .
2. Measure voltage between battery positive and negative termi- nals, (+) and ( −).
NOTE:
Key fob does not function if battery is not set correctly.
OK or NG
OK >> GO TO 2.
NG >> Replace battery.
2. CHECK KEY FOB FUNCTION
With CONSULT-II
Check key fob function in “DATA MONITOR” mode with CONSULT-
II. When pushing each button of key fob, the corresponding monitor
item should be turned as follows.
OK or NG
OK >> Key fob is OK.
NG >> Replace key fob. Voltage : 2.5 – 3.0V
SEL237W
Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCK RKE KEEP UNLK : ON
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK at the
same time RKE LCK-UNLOCK : ON
PIIA6468E
Page 882 of 4366
BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
Check ACC SwitchNIS001MT
1. CHECK ACC SWITCH
With CONSULT-II
Check ACC switch (“ACC ON SW”) in “DATA MONITOR” mode with
CONSULT-II.
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> ACC switch is OK.
NG >> Check the following.
10A fuse [No. 6, located in fuse block (J/B)]
Harness for open or short between BCM and fuse.
Monitor item Condition
ACC SW Ignition switch position is ACC or ON : ON
Ignition switch position is OFF : OFF
PIIA3367E
Item (+)
(–) Condition Voltage (V)
Approx.
Con-
nector Terminal
(Wire color)
BCM M3 11 (LG) Ground ACC or ON Battery voltage
OFF 0
PIIA7002E
Page 883 of 4366
REMOTE KEYLESS ENTRY SYSTEM BL-71
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
Check Door SwitchNIS001MU
CHECK DOOR SWITCH (EXCEPT BACK DOOR SWITCH)
1. CHECK DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check door switches (“DOOR SW-DR”, “DOOR SW-AS”, “DOOR
SW-RL” and “DOOR SW-RR”) in “DATA MONITOR” mode with
CONSULT-II.
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2.
Monitor item Condition DATA MONITOR
DOOR SW-DR CLOSE ↓
OPEN: OFF
↓
ON
DOOR SW-AS
DOOR SW-RL
DOOR SW-RR
Item Connector Terminals
(Wire color) Door
condition Voltage (V)
(Approx.)
(+) (-)
Driver side B14 62 (W)
Ground CLOSE
↓
OPEN Battery voltage
↓0
Rear LH 63 (P)
Passenger side M3 12 (P/B)
Rear RH 13 (P/L)
PIIA6469E
PIIA7003E
Page 884 of 4366

BL-72
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
2. CHECK DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM connector.
3. Check continuity between door switch connector B26, B36, B46, B206 terminals 1 and BCM connector M3, B14 terminals 62, 12,
63, 13.
4. Check continuity between door switch connector B26, B36, B46, B206 terminal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK DOOR SWITCH
Check continuity between door switch terminal 1 and ground part of
door switch.
OK or NG
OK >> Check door switch case ground condition.
NG >> Replace door switch. Driver side door
1 (W) – 62 (W) : Continuity should exist.
Passenger side door
1 (SB) – 12 (P/B) : Continuity should exist.
Rear door LH
1 (P) – 63 (P) : Continuity should exist.
Rear door RH
1 (P) – 13 (P/L) : Continuity should exist.
1 (W, SB, P) – Ground : Continuity should not exist.
PIIA7004E
Terminal Door switch condition Continuity
1 Ground part of door switch Pushed No
Released Yes
PIIA3351E