BL-56
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
room lamp and key ring illumination
OPERATED PROCEDURE
Power Door Lock Operation
BCM receives a LOCK signal from key fob. BCM locks all doors with input of LOCK signal from key fob.
When an UNLOCK signal is sent from key fob once, driver's door will be unlocked.
Then, if an UNLOCK signal is sent from key fob again within 5 seconds, all other door will be unlocked.
Power door lock operation mode can be changed using “DOOR LOCK-UNLOCK SET” mode in “WORK SUP-
PORT” of “POWER DOOR LOCK SYSTEM”.
Refer to BL-65, "
Work Support" .
Power door lock operation mode can be changed also on the display.
Hazard and Horn Reminder
When the doors are locked or unlocked by key fob, power is supplied to hazard warning lamp and lamp flash
as follows
LOCK operation: C mode (flash twice) or S mode (flash twice)
UNLOCK operation: C mode (flash once) or S mode (do not flash)
BCM outputs to IPDM E/R for horn reminder signal as DATA LINE (CAN H line and CAN L line).
The hazard and horn reminder has C mode (horn chirp mode) and S mode (non-horn chirp mode).
Operating function of hazard and horn reminder
Hazard and horn reminder do not operate if any door switch is ON (any door is OPEN).
How to change hazard and horn reminder mode
With CONSULT-II
Hazard and horn reminder can be changed using “MULTI ANSWER BACK SET” mode in “WORK SUPPORT”.
Refer to BL-65, "
Work Support" .
Without CONSULT-II
When LOCK and UNLOCK signals are sent from the key fob for more than 2 seconds at the same time, the
hazard and horn reminder mode is changed and hazard warning lamp flashes and horn sounds as follows:
Auto Door Lock Operation
Auto lock function signal is sent for operation when any of the following signals are not sent within 1 minute
after the unlock signal is sent from the key fob:
when door switch is turned ON for open.
when the key switch is turned ON.
when the lock signal is sent from the key fob.
Auto door lock mode can be changed using “AUTO LOCK SET” mode in “WORK SUPPORT”.
Refer to BL-65, "
Work Support" .
Auto door lock mode can be changed also on the display.
C mode S mode
Remote controller
operation Lock Unlock Lock Unlock
Hazard warning lamp
flash Twice Once Twice —
Horn sound Once — — —
SEL153WA
REMOTE KEYLESS ENTRY SYSTEM BL-57
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
Panic Alarm Operation
When key switch is OFF (when ignition key is not inserted in key cylinder), BCM turns on and off horn and
headlamp intermittently with input of PANIC ALARM signal from key fob.
The alarm automatically turns off after 25 seconds or when BCM receives any signal from key fob.
Panic alarm operation mode can be changed using “PANIC ALARM SET” mode in “WORK SUPPORT”.
Refer to BL-65, "
Work Support" .
For detailed description, refer to BL-180, "
VEHICLE SECURITY (THEFT WARNING) SYSTEM" .
Keyless Power Window Down (Open) Operation
When key fob unlock switch is turned ON with ignition switch OFF, and key fob unlock switch is detected to be
on continuously for 3 seconds, the driver's door and passenger's door power windows are simultaneously
opened.
Power window is operated to open and the operation continues as long as the key fob unlock switch is
pressed.
Keyless power window down operation mode can be changed using “PW DOWN SET” mode in “WORK SUP-
PORT”. Refer to BL-65, "
Work Support"
Room Lamp and Ignition Key Ring Illumination Operation
When the following conditions come:
condition of interior lamp switch is DOOR position;
door switch OFF (when all the doors are closed);
Remote keyless entry system turns on interior lamp (for 30 seconds) with input of UNLOCK signal from key
fob. For detailed description, refer to LT- 1 5 2 , "
INTERIOR ROOM LAMP" .
CAN Communication System DescriptionNIS001MJ
CAN (Controller Area Network) is a serial communication line for real time application. It is an on-vehicle mul-
tiplex communication line with high data communication speed and excellent error detection ability. Many elec-
tronic control units are equipped onto a vehicle, and each control unit shares information and links with other
control units during operation (not independent). In CAN communication, control units are connected with 2
communication lines (CAN H line, CAN L line) allowing a high rate of information transmission with less wiring.
Each control unit transmits/receives data but selectively reads required data only.
CAN Communication UnitNIS001MK
Refer to LAN-49, "CAN System Specification Chart" .
BL-62
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
Terminals and Reference Value for BCMNIS001MN
Te r m i -
nal Wire
Color Item Signal
Input/
output Condition
Voltage (V)
Approx.
1PU Key ring illumination output
signal Output Key ring illumination is lighting. Battery voltage
Key ring illumination is being
turned off. 0
11 LG Ignition switch Input Ignition switch is in ACC or ON
position Battery voltage
12 P/B Front door switch (Passen-
ger side) Input
ON (door open)
→ OFF (door
closed) 0
→ Battery voltage
13 P/L Rear door switch RH Input ON (door open)
→ OFF (door
closed) 0
→ Battery voltage
18 B Remote keyless entry
receiver (Ground) —— 0
19 R Remote keyless entry
receiver (Power supply) Output Key is inserted in IGN key cylinder 0
All door closed
20 Y Remote keyless entry
receiver (Signal) Input Key is inserted in IGN key cylinder 0
Waiting
(All door closed)
When signal is received
(All door closed)
37 B/W Key switch Input ON (Key is inserted in IGN key cyl-
inder) → OFF (Key is removed
from IGN key cylinder) Battery voltage
→ 0
38 W/L Ignition switch Input Ignition switch is in ON or START
position Battery voltage
39 L CAN H Input/
Output ——
40 P CAN L Input/
Output ——
41 R/B Battery saver output signal Output 30 minutes after ignition switch is
turned to OFF 0
Ignition switch is in ON position Battery voltage
42 L/R Battery power supply
(fuse) Input — Battery voltage
44 Y Driver door lock actuator
(Unlock) Output
Door lock / unlock switch
(Free → Unlock) 0
→ Battery voltage
OCC3881D
OCC3879D
OCC3880D
REMOTE KEYLESS ENTRY SYSTEM BL-63
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
*1 : In the state that hazard reminder operates.
*2 : In the state that room lamp switch is in “DOOR” position.
Terminals and Reference Value for IPDM E/RNIS001MO
* : In the state that horn reminder operates. 45 G/W Left turn signal lamp Output
When door lock or unlock is oper-
ated using key fob.*
1
(ON → OFF) Battery voltage
→ 0
46 BR/W Right turn signal lamp Output When door lock or unlock is oper-
ated using key fob.*
1
(ON → OFF) Battery voltage
→ 0
47 Y/R Step lamp output signal Output Step lamp is lighting. 0
Step lamp is being turned off. Battery voltage
48 PU/W Room lamp output signal Output Room lamp is lighting.*
20
Room lamp is being turned off.*
2Battery voltage
49 B Ground — — 0
50 PU Door lock actuator (Lock) Output Door lock / unlock switch
(Free → Lock) 0
→ Battery voltage
51 W/B Passenger and rear doors
lock actuator (Unlock) Output Door lock / unlock switch
(Free → Unlock) 0
→ Battery voltage
52 B Ground — — 0
54 W Battery power supply
(power window) Input — Battery voltage
55 G Battery power supply (Fus-
ible link) Input — Battery voltage
58 L Back door switch Input OFF (Door close)
→ ON (Door
open) 9
→ 0
62 W Front door switch (Driver
side) InputOFF (Door close)
→ ON (Door
open) Battery voltage
→ 0
63 P Rear door switch LH Input OFF (Door close)
→ ON (Door
open) Battery voltage
→ 0
Te r m i -
nal Wire
Color Item Signal
Input/
output Condition
Voltage (V)
Approx.
Te r m i -nal Wire
Color Item Signal
Input/
Output Condition
Voltage (V)
Approx.
38 B Ground — — 0
48 L CAN H Input/
Output ——
49 R CAN L Input/
Output ——
51 SB Horn relay Output When door lock is operated using
key fob* (OFF → ON) Battery voltage
→ 0
60 B Ground — — 0
BL-64
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
CONSULT-II Function (BCM)NIS001MP
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
*: Refer to LAN-49, "CAN System Specification Chart" .
CONSULT-II INSPECTION PROCEDURE
Refer to GI-38, "CONSULT-II Start Procedure" .
CONSULT-II APPLICATION ITEMS
Data Monitor
Active Test
BCM diagnosis position Inspection items and diagnosis mode Description
BCM C/U* Self-diagnosis results Carries out the self-diagnosis.
DATA MONITOR Displays the input data to BCM on real-time basis.
CAN DIAG SUPPORT MNTR Displays CAN communication system diagnosis, disabled
transmission status, and communication status of each unit
communicated with BCM.
MULTI REMOTE
ENT DATA MONITOR
Displays the input remote keyless entry system data to BCM
on real–time basis.
ACTIVE TEST Gives a drive to a load to check the operation.
WORK SUPPORT Changes the setting for each function.
Monitored Item Description
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEY ON SW Indicates [ON/OFF] condition of key switch.
ACC ON SW Indicates [ON/OFF] condition of ignition switch in ACC position.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from key fob.
KEYLWSS UNLOCK Indicates [ON/OFF] condition of unlock signal from key fob.
KEYLESS PANIC Indicates [ON/OFF] condition of panic signal from key fob.
KEYLESS TRUNK This is displayed even when it is not equipped.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch driver side.
DOOR SW-AS Indicates [ON/OFF] condition of door switch passenger side.
DOOR SW-RR Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door switch.
TRUNK OPN MNTR This is displayed even when it is not equipped.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from door lock and unlock switch.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from door lock and unlock switch.
RKE LCK-UNLOCK Indicates [ON/OFF] condition of simultaneous signal of lock and unlock from key fob.
RKE KEEP UNLK Indicates [ON/OFF] condition of unlock continuousness signal from key fob.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from door key cylinder switch.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from door key cylinder switch.
Test Item Description
FLASHER This test is able to check right hazard reminder operation. The right hazard lamp turns on when “ON” on CONSULT-II screen is touched.
POWER WINDOW DOWN This test is able to check power window open operation.
The front power windows activate for 10 seconds after “ON” on CONSULT-II screen is touched.
HORN This test is able to check panic alarm and horn reminder operations. The horn activate for 0.5 seconds after “ON” on CONSULT-II screen is touched.
REMOTE KEYLESS ENTRY SYSTEM BL-73
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
CHECK BACK DOOR SWITCH
1. CHECK BACK DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check (“BACK DOOR SW”) in “DATA MONITOR” mode with CONSULT-II.
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> GO TO 2.
2. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect BCM and back door closure motor connector.
3. Check continuity between BCM connector B14 terminal 58 and back door closure motor connector D109 terminal 7.
4. Check continuity between BCM connector B14 terminal 58 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Monitor item Condition DATA MONITOR
BACK DOOR SW OPEN
↓
CLOSE ON
↓
OFF
PIIA2488E
Connector Terminals (Wire color)
Condition Voltage (V)
(Approx.)
(+) (–)
B14 58 (L) Ground OPEN 0
CLOSE 9
PIIA6229E
58 (L) – 7 (L) : Continuity should exist.
58 (L) – Ground : Continuity should not exist.
PIIA6226E
BL-76
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
Check Remote Keyless Entry ReceiverNIS001MW
1. CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
1. Turn ignition switch OFF.
2. Check remote keyless entry receiver connector M98 terminal 2 (L) and ground signal with oscilloscope.
OK or NG
OK >> Remote keyless entry receiver circuit is OK.
NG >> GO TO 2.
2. CHECK REMOTE KEYLESS ENTRY RECEIVER INPUT VOLTAGE
1. Disconnect remote keyless entry receiver connector.
2. Check voltage between remote keyless entry receiver connector M98 terminal 4 (R) and ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
Connector Terminal
(Wire color) Condition
of keyfob Vo l ta g e
(Reference value)
(+) (–)
M98 2 Ground No function
Any button is pressed
PIIB1375E
OCC3879D
OCC3880D
4 (Y) – Ground : Approx. 4.5V
PIIB3953E
BL-80
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
Check Hazard Warning Lamp FunctionNIS001MY
1. CHECK HAZARD WARNING LAMP
Do hazard warning lamp flash with hazard switch?
YES or NO
YES >> Hazard warning lamp circuit is OK.
NO >> Check hazard circuit. Refer to LT- 9 0 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Check Horn FunctionNIS001MZ
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-13, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HORN FUNCTION
Does horn sound with horn switch?
YES or NO
YES >> Horn circuit is OK.
NO >> Check horn circuit. Refer to WW-58, "
HORN" .
Check Headlamp FunctionNIS001N0
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-13, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HEADLAMP FUNCTION
Does headlamp come on when turning lighting switch “ON”?
YES or NO
YES >> Headlamp operation circuit is OK.
NO >> Check headlamp system. Refer to LT- 6 , "
HEADLAMP - XENON TYPE -" .
Check Map Lamp and Ignition Keyhole Illumination FunctionNIS001N1
1. CHECK MAP LAMP AND IGNITION KEYHOLE ILLUMINATION FUNCTION
When map lamp switch is in “DOOR” position, open the front door (LH or RH).
OK or NG
OK >> Replace BCM.
NG >> Check ignition illumination circuit. Refer to LT- 1 5 2 , "
INTERIOR ROOM LAMP" .
Map lamp and ignition keyhole illumination should illuminate.