BL-50
POWER DOOR LOCK SYSTEM
Revision: June 20062007 Versa
Front Door Key Cylinder Switch LH CheckEIS009CC
1. CHECK FRONT DOOR KEY CYLINDER SWITCH LH
With CONSULT-II
Check front door key cylinder switch ("KEY CYL LK-SW") and ("KEY CYL UN-SW) in DATA MONITOR mode
in CONSULT–II. Refer to BL-37, "
DATA MONITOR" .
When key inserted in front key cylinder is turned to LOCK:
When key inserted in front key cylinder is turned to UNLOCK:
Without CONSULT-II
Check voltage between BCM connector M18 terminals 7, 8 and
ground.
OK or NG
OK >> Front door key cylinder switch LH signal is OK.
NG >> GO TO 2.
2. CHECK FRONT DOOR KEY CYLINDER SWITCH LH GROUND HARNESS
1. Turn ignition switch OFF.
2. Disconnect front door key cylinder switch LH.
3. Check continuity between front door key cylinder switch LH con-
nector D14 terminal 2 and body ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.KEY CYL LK-SW : ON
KEY CYL UN-SW : ON
LIIA0188E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
( + ) ( – )
M187
GroundNeutral/Lock 5
Unlock 0
8Neutral/Unlock 5
Lock 0
WIIA1247E
Connector Terminals Continuity
D14 2 – Ground Yes
WIIA1248E
POWER DOOR LOCK SYSTEM
BL-51
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
3. CHECK DOOR KEY CYLINDER SWITCH LH
Check continuity between front door key cylinder switch LH termi-
nals.
OK or NG
OK >> GO TO 4.
NG >> Replace front door key cylinder switch LH. Refer to BL-169, "
FRONT DOOR LOCK" .
4. CHECK DOOR KEY CYLINDER HARNESS
1. Disconnect BCM connector M18.
2. Check continuity between BCM connector (A) M18 terminals 7,
8 and front door key cylinder switch LH connector (B) D14 termi-
nals 1, 3 and body ground.
OK or NG
OK >> Front door key cylinder switch LH circuit is OK.
NG >> Repair or replace harness.
Passenger Select Unlock Relay Circuit Check (With Intelligent Key)EIS009CD
1. CHECK PASSENGER SELECT UNLOCK RELAY CIRCUIT
NOTE:
Passenger select unlock relay must remain connected during this step.
1. Turn ignition switch OFF.
2. Disconnect BCM and inoperative rear door lock actuator.
3. Check continuity between BCM connector (A) M20 terminal 65
and rear door lock actuator LH connector (B) D205 terminal 3 or
rear door lock actuator RH connector (C) D305 Terminal 3.
4. Check continuity between BCM connector M20 terminal 65 and
body ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 2.
Terminals Door key cylinder switch position Continuity
2 – 1 Neutral/Unlock No
Lock Yes
2 – 3Neutral/Lock No
Unlock Yes
WIIA1249E
Connector Terminal Connector Terminal Continuity
A: M187
B: D143Yes
81Yes
7 Ground No
8 Ground No
WIIA1250E
65 - 3 : Continuity should exist.
65 - Ground : Continuity should not exist.
WIIA1164E
REMOTE KEYLESS ENTRY SYSTEM
BL-55
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
System DescriptionEIS0091A
INPUTS
Power is supplied at all times
through 40A fusible link (letter g , located in the fuse and fusible link box)
to BCM terminal 70
through 10A fuse [No. 8, located in the fuse block (J/B)]
to BCM terminal 57.
When the key switch is ON (key is inserted in ignition key cylinder), power is supplied
through 10A fuse [No. 14, located in the fuse block (J/B)]
through key switch terminals 2 and 1
to BCM terminal 37.
When the ignition switch is ACC or ON, power is supplied
through 10A fuse [No. 20, located in the fuse block (J/B)]
to BCM terminal 11.
Ground is supplied
to BCM terminal 67
through body grounds M57 and M61.
When the front door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 47
through front door switch LH terminal 2
through front door switch LH case ground.
When the front door switch RH is ON (door is OPEN), ground is supplied
to BCM terminal 12
through front door switch RH terminal 2
through front door switch RH case ground.
When the rear door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 48
through rear door switch LH terminal 1
through rear door switch LH case ground.
When the rear door switch RH is ON (door is OPEN), ground is supplied
to BCM meter terminal 13
through rear door switch RH terminal 1
through rear door switch RH case ground.
When the back door lock assembly (back door switch) is ON (back door is OPEN), ground is supplied
to BCM terminal 43
through back door lock assembly (back door switch) terminals 3 and 4
through body grounds B117, B132 and D402.
Keyfob signal is inputted to BCM from remote keyless entry receiver.
The remote keyless entry system controls operation of the
power door lock
hazard reminder
auto door lock
panic alarm
room lamp
BL-56
REMOTE KEYLESS ENTRY SYSTEM
Revision: June 20062007 Versa
OPERATED PROCEDURE
Power Door Lock Operation
BCM receives a LOCK signal from keyfob. BCM locks all doors with input of LOCK signal from keyfob.
BCM receives a UNLOCK signal from keyfob. BCM unlocks all doors with input of UNLOCK signal from key-
fob.
Hazard and Horn Reminder
When the doors are locked or unlocked by keyfob, power is supplied to sound horns and flash hazard warning
lamps as follows
LOCK operation: 3 or 4 mode (lamps flash twice)
UNLOCK operation: 2 or 4 mode (lamps flash once)
Horns sound once with LOCK function when this feature is set ON.
The hazard reminder has modes 1, 2, 3 or 4. The horn reminder can be turned ON/OFF with any LOCK mode.
Operating function of hazard reminder
Hazard and horn reminders do not operate if any door switch is ON (any door is OPEN).
How to change hazard and horn reminder modes
With CONSULT-II
Hazard reminder can be changed using “HAZARD LAMP SET” mode in “WORK SUPPORT”.
Horn reminder can be changed using “HORN CHIRP SET” mode in “WORK SUPPORT”.
Refer to BL-61, "
Work Support" .
Without CONSULT-II
Refer to Owner's Manual for instructions.
Auto Door Lock Operation
Auto lock function signal is sent for operation when any of the following signals are not sent within 1 minute
after the unlock signal is sent from the keyfob:
when door switch is turned ON for open.
when the key switch is turned ON.
when the lock signal is sent from the keyfob.
Auto door lock mode can be changed using “AUTO LOCK SET” mode in “WORK SUPPORT”.
Refer to BL-61, "
Work Support" .
Panic Alarm Operation
When key switch is OFF (when ignition key is not inserted in key cylinder), BCM turns on and off horn intermit-
tently with input of PANIC ALARM signal from keyfob.
BCM outputs to IPDM E/R for panic alarm signal (horn signal) as DATA LINE (CAN H line and CAN L line).
The alarm automatically turns off after 25 seconds or when BCM receives any signal from keyfob.
Panic alarm operation mode can be changed using “PANIC ALARM SET” mode in “WORK SUPPORT”.
Refer to BL-61, "
Work Support" .
Interior Lamp Operation
When the following conditions come:
condition of interior lamp switch is in the DOOR position;
door switch OFF (when all the doors are closed);
Remote keyless entry system turns on interior lamp (for 30 seconds) with input of UNLOCK signal from key-
fob. For detailed description, refer to LT- 9 1 , "
INTERIOR ROOM LAMP" .
CAN Communication System DescriptionEIS0091B
Refer to LAN-4, "SYSTEM DESCRIPTION" .
Mode 1 Mode 2 Mode 3 Mode 4
Keyfob operation Lock Unlock Lock Unlock Lock Unlock Lock Unlock
Hazard warning lamp
flash— — — Twice Once — Once Twice
Horns sound (ON/OFF) ON: once — ON: once — ON: once — ON: once —
BL-62
REMOTE KEYLESS ENTRY SYSTEM
Revision: June 20062007 Versa
PANIC ALARM SET
HAZARD LAMP BACK SET
AUTO LOCK SET
TRUNK OPEN
Data Monitor
Active Test
AUTO LOCK SETAuto locking function mode can be changed in this mode. The function mode will be
changed when “CURRENT SETTING” on CONSULT-II screen is touched.
TRUNK OPENKeyless trunk open operation mode can be changed in this mode. The operation mode will
be changed when “CURRENT SETTING” on CONSULT-II screen is touched. Test Item Description
MODE 1 MODE 2 MODE 3
Keyfob operation 0.5 seconds Nothing 1.5 seconds
MODE 1 MODE 2 MODE 3 MODE 4
Hazard lamp operation mode Nothing Unlock only Lock only Lock and Unlock
MODE 1 MODE 2 MODE 3
Auto locking function 30 seconds Nothing 1 minutes
MODE 1 MODE 2 MODE 3
Keyfob operation 0.5 seconds Nothing 1.5 seconds
Monitored Item Description
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEY ON SW Indicates [ON/OFF] condition of key switch.
ACC ON SW Indicates [ON/OFF] condition of ignition switch in ACC position.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from keyfob.
KEYLWSS UNLOCK Indicates [ON/OFF] condition of unlock signal from keyfob.
KYLS TRNK/HAT This is displayed even when it is not equipped.
KEYLESS PSD This is displayed even when it is not equipped.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch driver side.
DOOR SW-AS Indicates [ON/OFF] condition of front door switch passenger side.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
BACK DOOR SW This is displayed even when it is not equipped.
TRNK/HAT MNTR Indicates [ON/OFF] condition of trunk room lamp switch.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from door lock and unlock switch.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from door lock and unlock switch.
KEYLESS PANIC Indicates [ON/OFF] condition of panic alarm signal from keyfob.
Test Item Description
INT LAMPThis test is able to check interior room lamp operation.
The interior room lamp turns on when “ON” on CONSULT-II screen is touched.
FLASHERThis test is able to check right hazard reminder operation.
The right hazard lamp turns on when “ON” on CONSULT-II screen is touched.
DOOR LOCKThis test is able to check door lock actuator operation.
The all door lock actuator are locked when “ALL LOCK” on CONSULT-II screen is touched.
The all door lock actuator are unlocked when “ALL UNLOCK” on CONSULT-II screen is touched.
REMOTE KEYLESS ENTRY SYSTEM
BL-67
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
ACC Switch CheckEIS0091J
1. CHECK ACC SWITCH
With CONSULT-II
Check ACC switch (“ACC ON SW”) in “DATA MONITOR” mode with CONSULT-II.
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> ACC switch is OK.
NG >> Check the following.
10A fuse [No. 20, located in fuse block (J/B)]
Harness for open or short between BCM and fuse.
Monitor item Condition
ACC ON SWIgnition switch position is ACC or ON : ON
Ignition switch position is OFF : OFF
PIIA3367E
Te r m i n a l s
Ignition switch
conditionVoltage (V)
(Approx.) (+)
(–)
BCM connector Terminal
M18 11 GroundACC or ON Battery voltage
OFF 0
PIIB6453E
REMOTE KEYLESS ENTRY SYSTEM
BL-69
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
2. CHECK DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM.
3. Check continuity between door switch connector (B) B8 (front LH), B108 (front RH) terminal 2 or (C) B6
(rear LH), B116 (rear RH) terminal 1 or back door lock assembly connector (D) D405 terminal 3 and BCM
connectors (A) M18, M19 terminals 12, 13, 43, 47 and 48.
4. Check continuity between door switch connector (B) B8 (front
LH), B108 (front RH) terminal 2 or (C) B6 (rear LH), B116 (rear
RH) terminal 1 or back door lock assembly connector (D) D405
terminal 3 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK DOOR SWITCHES
FRONT AND REAR DOORS
Check continuity between front door switch terminal 2 or rear door
switch terminal 1 and exposed metal of switch while pressing and
releasing switch.
BACK DOOR
Check continuity between back door lock assembly connector (back
door switch) terminals 3 and 4 while pressing (closing back door)
and releasing (opening back door) switch.
OK or NG
OK >> (Front and rear doors) Switch circuit is OK.
OK >> (Back door) GO TO 4.
NG >> Replace door switch.1 - 13 : Continuity should exist.
1 - 48 : Continuity should exist.
2 - 12 : Continuity should exist.
2 - 47 : Continuity should exist.
3 - 43 : Continuity should exist.
1 - Ground : Continuity should not exist.
2 - Ground : Continuity should not exist.
3 - Ground : Continuity should not exist.
WIIA1244E
Door switch is released : Continuity should exist.
Door switch is pushed : Continuity should not exist.
PIIB6899E
When back door is open : Continuity should exist.
When back door is closed : Continuity should not exist.
WIIA1245E
BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: June 20062007 Versa
4. CHECK BACK DOOR SWITCH GROUND
Check continuity between back door lock assembly connector D405
terminal 4 and ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Key Switch (Insert) CheckEIS0091L
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-37, "
DATA MONI-
TOR" .
When key is inserted into ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Key switch circuit is OK.
NG >> GO TO 2.4 - Ground : Continuity should exist.
WIIA1246E
KEY ON SW : ON
KEY ON SW : OFF
LIIA0169E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
( + ) ( – )
M18 37 GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E