POWER DOOR LOCK SYSTEM
BL-25
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
When the front door switch RH is ON (door is OPEN), ground is supplied
to BCM terminal 12
through front door switch RH terminal 2
through front door switch RH case ground.
When the rear door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 48
through rear door switch LH terminal 1
through rear door switch LH case ground.
When the rear door switch RH is ON (door is OPEN), ground is supplied
to BCM terminal 13
through rear door switch RH terminal 1
through rear door switch RH case ground.
When the back door switch is ON (back door is OPEN), ground is supplied
to BCM terminal 43
through back door switch terminals 3 and 4
through body grounds B117, B132 and D402.
OUTLINE
Functions available by operating the inside door lock and unlock switches
Interlocked with the locking operation of door lock and unlock switch, door lock actuators of all doors are
locked.
Interlocked with the unlocking operation of door lock and unlock switch, door lock actuators of all doors
are unlocked.
Functions available by operating the front door key cylinder switch LH
Interlocked with the locking operation of front door key cylinder switch LH, door lock actuators of all doors
are locked.
When front door key cylinder switch LH is unlocked, front door lock actuator LH is unlocked.
When front door key cylinder switch LH is unlocked for the second time within 5 seconds after the first
operation, door lock actuators on all doors are unlocked.
Key reminder door system
When door lock and unlock switch is operated to lock doors with ignition key inserted in key cylinder and any
door open, all door lock actuators are locked and then unlocked.
CAN Communication System DescriptionEIS0090W
Refer to LAN-4, "SYSTEM DESCRIPTION" .
POWER DOOR LOCK SYSTEM
BL-37
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Terminals and Reference Value for BCMEIS0090Z
Refer to BCS-12, "Terminals and Reference Values for BCM" .
Work FlowEIS009BY
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to BL-24, "
System Description" .
3. According to the trouble diagnosis chart, repair or replace the cause of the malfunction. Refer to BL-114,
"Trouble Diagnosis Symptom Chart" .
4. Does power door lock system operate normally? OK: GO TO 5, NG: GO TO 3.
5. Inspection End.
CONSULT–II Function (BCM)EIS009BZ
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT–II START PROCEDURE
Refer to GI-38, "CONSULT-II Start Procedure" .
WORK SUPPORT
DATA MONITOR
BCM
diagnostic test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the
BCM for setting the status suitable for required operation, input/output sig-
nals are received from the BCM and received date is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TESTOperation of electrical loads can be checked by sending drive signal to
them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTRThe result of transmit/receive diagnosis of CAN communication can be
read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
Work item Description
DOOR LOCK-UNLOCK SET Select unlock mode can be changed in this mode. Selects ON-OFF of select unlock mode.
ANTI-LOCK OUT SETKey reminder door mode can be changed in this mode. Selects ON-OFF of key reminder door
mode.
Monitor item Content
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEY ON SW Indicates [ON/OFF] condition of key switch.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from door lock and unlock switch.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from door lock and unlock switch.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch LH.
DOOR SW-AS Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door switch.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from key cylinder.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from key cylinder.
KEYLESS LOCK* Indicates [ON/OFF] condition of lock signal from keyfob.
KEYLESS UNLOCK* Indicates [ON/OFF] condition of unlock signal from keyfob.
POWER DOOR LOCK SYSTEM
BL-41
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
2. CHECK DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM.
3. Check continuity between door switch connector (B) B8 (front LH), B108 (front RH) terminal 2 or (C) B6
(rear LH), B116 (rear RH) terminal 1 or back door lock assembly connector (D) D405 terminal 3 and BCM
connectors (A) M18, M19 terminals 12, 13, 43, 47 and 48.
4. Check continuity between door switch connector (B) B8 (front
LH), B108 (front RH) terminal 2 or (C) B6 (rear LH), B116 (rear
RH) terminal 1 or back door lock assembly connector (D) D405
terminal 3 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK DOOR SWITCHES
FRONT AND REAR DOORS
Check continuity between front door switch terminal 2 or rear door
switch terminal 1 and exposed metal of switch while pressing and
releasing switch.
BACK DOOR
Check continuity between back door lock assembly connector (back
door switch) terminals 3 and 4 while pressing (closing back door)
and releasing (opening back door) switch.
OK or NG
OK1 >> (Front and rear doors) Switch circuit is OK.
OK2 >> (Back door) GO TO 4.
NG >> Replace door switch.1 - 13 : Continuity should exist.
1 - 48 : Continuity should exist.
2 - 12 : Continuity should exist.
2 - 47 : Continuity should exist.
3 - 43 : Continuity should exist.
1 - Ground : Continuity should not exist.
2 - Ground : Continuity should not exist.
3 - Ground : Continuity should not exist.
WIIA1244E
Door switch is released : Continuity should exist.
Door switch is pushed : Continuity should not exist.
PIIB6899E
When back door is open : Continuity should exist.
When back door is closed : Continuity should not exist.
WIIA1245E
POWER DOOR LOCK SYSTEM
BL-43
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Key Switch (Insert) CheckEIS00915
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-37, "
DATA MONI-
TOR" .
When key is inserted into ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Key switch circuit is OK.
NG-1 >> GO TO 2 (with Intelligent Key).
NG-2 >> GO TO 3 (without Intelligent Key).
2. CHECK KEY SWITCH (WITH INTELLIGENT KEY)
1. Turn ignition switch OFF.
2. Disconnect key switch and ignition knob switch connector.
3. Check ignition knob switch key switch and ignition knob key switch.
OK or NG
OK >> Check the following.
10A fuse (No. 31, located in fuse and fusible link
block)
Harness for open or short between key switch and ignition knob switch and fuse
Harness for open or short between BCM and key switch and ignition knob switch
NG >> Replace key switch and ignition knob switch.KEY ON SW : ON
KEY ON SW : OFF
LIIA0169E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
( + ) ( – )
M18 37 GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E
Terminal
Condition Continuity
Key switch and ignition knob
switch
12KeyInserted Yes
Removed No
PIIB6411E
BL-44
POWER DOOR LOCK SYSTEM
Revision: June 20062007 Versa
3. CHECK KEY SWITCH (WITHOUT INTELLIGENT KEY)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid connector.
3. Check key switch.
OK or NG
OK >> Check the following.
10A fuse [No. 14, located in fuse block (J/B)]
Harness for open or short between key switch and
fuse
Harness for open or short between BCM and key
switch
NG >> Replace key switch and key lock solenoid.
Terminals Condition Continuity
1 – 2Key is inserted. Yes
Key is removed. No
PIIB6411E
BL-46
POWER DOOR LOCK SYSTEM
Revision: June 20062007 Versa
2. CHECK DOOR LOCK/UNLOCK SWITCH
1. Turn ignition switch OFF.
2. Disconnect door lock/unlock switch.
3. Check continuity between main power window and door lock/
unlock switch terminals 6, 17 and 18.
4. Check continuity between power window and door lock/unlock
switch RH terminals 1, 2 and 3.
OK or NG
OK >> GO TO 3.
NG >> Replace door lock/unlock switch.
3. CHECK DOOR LOCK/UNLOCK SWITCH GROUND HARNESS
1. Disconnect main power window and door lock/unlock switch or power window and door lock/unlock switch
RH.
2. Check continuity between main power window and door lock/
unlock switch connector D8 terminal 17 and ground.
3. Check continuity between power window and door lock/unlock
switch RH connector D105 terminal 3 and ground
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
Terminal Condition Continuity
18
17Lock Yes
Unlock/Neutral No
6Unlock Yes
Lock/Neutral No
WIIA1107E
Terminal Condition Continuity
1
3Lock Yes
Unlock/Neutral No
2Unlock Yes
Lock/Neutral No
WIIA1108E
17 - Ground : Continuity should exist.
WIIA1109E
3 - Ground : Continuity should exist.
WIIA0450E
BL-48
POWER DOOR LOCK SYSTEM
Revision: June 20062007 Versa
Front Door Lock Assembly LH (Actuator) CheckEIS009CA
1. CHECK FRONT DOOR LOCK ASSEMBLY LH (ACTUATOR) HARNESS
1. Turn ignition switch OFF.
2. Disconnect BCM and front door lock assembly LH (actuator).
3. Check continuity between BCM connector (A) M20 terminals 59,
65 and front door lock assembly LH (actuator) connector (B) D3
terminals 2, 3.
4. Check continuity between BCM connector (A) M20 terminals 59,
65 and body ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
2. CHECK FRONT DOOR LOCK ASSEMBLY LH SIGNAL
1. Reconnect BCM.
2. Check voltage between BCM connector M20 terminals 59, 65
and ground.
OK or NG
OK >> Replace front door lock assembly LH (actuator). Refer to BL-169, "Removal and Installation" .
NG >> Replace BCM. Refer to BCS-25, "
Removal and Installation of BCM" .
Connector Terminal Connector Terminal Continuity
A: M2059
B: D32Yes
65 3 Yes
Connector Terminals Continuity
A: M2059
GroundNo
65 No
LIIA2525E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M2059
GroundMain power window and
door lock/unlock switch
is turned to UNLOCK0 → Battery voltage
65Main power window and
door lock/unlock switch
is turned to LOCK0 → Battery voltage
LIIA1355E
POWER DOOR LOCK SYSTEM
BL-49
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Door Lock Actuator Check (Front RH and Rear LH/RH)EIS009CB
1. CHECK DOOR LOCK ACTUATOR HARNESS
NOTE:
For models with Intelligent Key, insure that passenger select unlock relay remains connected during this test.
1. Turn ignition switch OFF.
2. Disconnect BCM and each door lock actuator.
3. Check continuity between BCM connector (A) M20 terminals 65,
66 and front door lock actuator RH connector (B) D114, rear
door lock actuator RH connector (B) D305, rear door lock actua-
tor LH connector (C) D205 terminals 2, 3.
4. Check continuity between BCM connector (A) M20 terminals 65,
66 and body ground.
OK or NG
OK >> GO TO 2.
NG >> Check the following:
Without Intelligent Key: Repair or replace harness.
With Intelligent Key: For front doors, repair or replace harness.
With Intelligent Key: For rear door, repair or replace harness or passenger select unlock relay.
2. CHECK DOOR LOCK ACTUATOR SIGNAL
1. Reconnect BCM.
2. Check voltage between BCM connector M20 terminals 65, 66
and ground.
OK or NG
OK >> Replace front door lock assembly RH or rear door lock actuator LH/RH. Refer to BL-169,
"Removal and Installation" or BL-172, "Removal and Installation" .
NG >> Replace BCM. Refer to BCS-25, "
Removal and Installation of BCM" .
Connector Terminal Connector Terminal Continuity
A: M2065 B: D114
C: D205
D: D3053Yes
66 2 Yes
Connector Terminals Continuity
A: M2065
GroundNo
66 No
LIIA2526E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M2065
GroundMain power window and
door lock/unlock switch is
turned to UNLOCK0 → Battery voltage
66Main power window and
door lock/unlock switch is
turned to LOCK0 → Battery voltage
LIIA1357E