2006 INFINITI M35 ignition

[x] Cancel search: ignition

Page 1719 of 5621

INFINITI M35 2006  Factory Service Manual EC-176
[VQ35DE]
DTC U1010 CAN COMMUNICATION
Revision: 2006 January2006 M35/M45
DTC U1010 CAN COMMUNICATIONPFP:23710
DescriptionNBS004TP
CAN (Controller Area Network) is a serial communication line for

Page 1720 of 5621

INFINITI M35 2006  Factory Service Manual DTC U1010 CAN COMMUNICATION
EC-177
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
Diagnostic ProcedureNBS004TS
1. INSPECTION START
 With CONSULT-II
1. Turn ignition switch ON.
2

Page 1722 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0011, P0021 IVT CONTROL
EC-179
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
On Board Diagnosis LogicNBS004TV
FAIL-SAFE MODE
When the malfunction is detected, the ECM ente

Page 1725 of 5621

INFINITI M35 2006  Factory Service Manual EC-182
[VQ35DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2006 January2006 M35/M45
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATERPFP:22693
DescriptionNBS004U0
SYSTEM DESCRIPTION

Page 1729 of 5621

INFINITI M35 2006  Factory Service Manual EC-186
[VQ35DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse s

Page 1730 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
EC-187
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnec

Page 1733 of 5621

INFINITI M35 2006  Factory Service Manual EC-190
[VQ35DE]
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2006 January2006 M35/M45
DTC Confirmation ProcedureNBS004UB
NOTE:
If  DTC  Confirmation  Procedure  has  been  previously  conduct

Page 1735 of 5621

INFINITI M35 2006  Factory Service Manual EC-192
[VQ35DE]
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION: