DTC P0102, P0103 MAF SENSOR EC-867
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC P0102, P0103 MAF SENSORPFP:22680
Component DescriptionNBS0043L
The mass air flow sensor is placed in the stream of intake air. It mea-
sures the intake flow rate by measuring a part of the entire intake
flow. The mass air flow sensor controls the temperature of the hot
wire to a certain amount. The heat generated by the hot wire is
reduced as the intake air flows around it. The more air, the greater
the heat loss.
Therefore, the electric current supplied to hot wire is changed to
maintain the temperature of the hot wire as air flow increases. The
ECM detects the air flow by means of this current change.
CONSULT-II Reference Value in Data Monitor ModeNBS0043M
Specification data are reference values.
On Board Diagnosis LogicNBS0043N
These self-diagnoses have the one trip detection logic.
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode and the MIL lights up.
PBIB1604E
MONITOR ITEM CONDITION SPECIFICATION
MAS A/F SE-B1 See EC-801, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
CAL/LD VALUE
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No load Idle 14% - 33%
2,500 rpm 12% - 25%
MASS AIRFLOW
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No load Idle 2.0 - 6.0 g·m/s
2,500 rpm 7.0 - 20.0 g·m/s
DTC No. Trouble diagnosis
name DTC detecting condition Possible cause
P0102
0102 Mass air flow sensor
circuit low input An excessively low voltage from the sensor is
sent to ECM.
Harness or connectors
(The sensor circuit is open or shorted.)
Intake air leaks
Mass air flow sensor
P0103
0103 Mass air flow sensor
circuit high input An excessively high voltage from the sensor is
sent to ECM.
Harness or connectors
(The sensor circuit is open or shorted.)
Mass air flow sensor
Detected items Engine operating condition in fail-safe mode
Mass air flow sensor circuit Engine speed will not rise more than 2,400 rpm due to the fuel cut.
EC-892
[VK45DE]
DTC P0125 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
DTC P0125 ECT SENSORPFP:22630
Component DescriptionNBS0044F
NOTE:
If DTC P0125 is displayed with P0117 or P0118, first perform the trouble diagnosis for DTC P0117 or
P0118. Refer to EC-879
.
The engine coolant temperature sensor is used to detect the engine
coolant temperature. The sensor modifies a voltage signal from the
ECM. The modified signal returns to the ECM as the engine coolant
temperature input. The sensor uses a thermistor which is sensitive to
the change in temperature. The electrical resistance of the ther-
mistor decreases as temperature increases.
*: These data are reference values and are measured between ECM terminal 73
(Engine coolant temperature sensor) and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
On Board Diagnosis LogicNBS0044G
SEF594K
Engine coolant
temperature °C ( °F) Voltage* V Resistance k
Ω
–10 (14) 4.4 7.0 - 11.4 20 (68) 3.5 2.1 - 2.9
50 (122) 2.2 0.68 - 1.00
90 (194) 0.9 0.236 - 0.260
SEF012P
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0125
0125 Insufficient engine cool-
ant temperature for
closed loop fuel control
Voltage sent to ECM from the sensor is not
practical, even when some time has passed
after starting the engine.
Engine coolant temperature is insufficient for
closed loop fuel control.
Harness or connectors
(High resistance in the circuit)
Engine coolant temperature sensor
Thermostat
EC-900
[VK45DE]
DTC P0130, P0150 A/F SENSOR 1
Revision: 2006 December 2006 FX35/FX45
DTC P0130, P0150 A/F SENSOR 1PFP:22693
Component DescriptionNBS004KF
The air fuel ratio (A/F) sensor 1 is a planar dual-cell limit current sen-
sor. The sensor element of the A/F sensor 1 is the combination of a
Nernst concentration cell (sensor cell) with an oxygen-pump cell,
which transports ions. It has a heater in the element.
The sensor is capable of precise measurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range (0.7 < < air).
The exhaust gas components diffuse through the diffusion gap at the
electrode of the oxygen pump and Nernst concentration cell, where
they are brought to thermodynamic balance.
An electronic circuit controls the pump current through the oxygen-
pump cell so that the composition of the exhaust gas in the diffusion
gap remains constant at = 1. Therefore, the A/F sensor 1 is able to
indicate air/fuel ratio by this pumping of current. In addition, a heater
is integrated in the sensor to ensure the required operating tempera-
ture of 700 - 800 °C (1,292 - 1,472 °F).
CONSULT-II Reference Value in Data Monitor ModeNBS004KG
Specification data are reference values.
On Board Diagnosis LogicNBS004KH
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the A/F sensor 1
signal fluctuates according to fuel feedback control.
SEF579Z
SEF580Z
MONITOR ITEM CONDITION SPECIFICATION
A/F SEN1 (B1)
A/F SEN1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm Fluctuates around 1.5 V
DTC No. Trouble diagnosis name DTC detecting condition Possible Cause
P0130
0130
(Bank 1) Air fuel ratio (A/F) sensor 1
circuit The A/F signal computed by ECM from the A/F
sensor 1 signal is constantly approx. 1.5V.
Harness or connectors
(The A/F sensor 1 circuit is open or
shorted.)
A/F sensor 1
P0150
0150
(Bank 2)
DTC P0130, P0150 A/F SENSOR 1 EC-901
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS004KI
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “A/F SEN1 (B1)” or “A/F SEN1 (B2)” in “DATA MONITOR” mode with CONSULT-II.
3. Check “A/F SEN1 (B1)” or “A/F SEN1 (B2)” indication. If the indication is constantly approx. 1.5V and does not fluctuates, go to EC-906, "
Diagnostic Procedure" .
If the indication fluctuates around 1.5V, go to next step.
4. Select “A/F SEN1 (B1) P1276” (for DTC P0130) or “A/F SEN1 (B2) P1286” (for DTC P0150) of “A/F SEN1” in “DTC WORK SUPPORT” mode with CONSULT-II.
5. Touch “START”.
6. When the following conditions are met, “TESTING” will be dis- played on the CONSULT-II screen.
If “TESTING” is not displayed after 20 seconds, retry from
step 2.
7. Release accelerator pedal fully. NOTE:
Never apply brake during releasing the accelerator pedal.
8. Make sure that “TESTING” changes to “COMPLETED”. If “TESTING” changed to “OUT OF CONDITION”, retry from
step 6.
9. Make sure that “OK” is displayed after touching “SELF-DIAG RESULT”.
If “NG” is displayed, go to EC-906, "
Diagnostic Procedure" .
ENG SPEED 1,300 - 3,200 rpm
Vehicle speed More than 64 km/h (40 MPH)
B/FUEL SCHDL 1.0 - 8.0 msec
Selector lever D position
SEF576Z
SEF577Z
SEF578Z
DTC P0130, P0150 A/F SENSOR 1 EC-907
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnect air fuel ratio (A/F) sensor 1 harness connector.
2. Turn ignition switch ON.
3. Check voltage between A/F sensor 1 terminal 3 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E19, F49
IPDM E/R connector E7
10A fuse
Harness for open or short between A/F sensor 1 and fuse
>> Repair or replace harness or connectors.
: Vehicle front 1. A/F sensor 1 (bank 2) harness con- nector 2. A/F sensor 1 (bank 1) harness con-
nector
Voltage: Battery voltage
PBIB3246E
PBIB1683E
EC-908
[VK45DE]
DTC P0130, P0150 A/F SENSOR 1
Revision: 2006 December 2006 FX35/FX45
4. CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between A/F sensor 1 terminal and ECM terminal as follows. Refer to Wiring Diagram.
4. Check harness continuity between the following terminals and ground. Refer to Wiring Diagram.
5. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK INTERMITTENT INCIDENT
Perform EC-811, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> GO TO 6.
NG >> Repair or replace.
6. REPLACE AIR FUEL RATIO (A/F) SENSOR 1
Replace air fuel ratio (A/F) sensor 1.
CAUTION:
Discard any A/F sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
Before installing new A/F sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
>> INSPECTION END
A/F sensor 1 terminal ECM terminal
Bank1 116
275
535
656
Bank 2 176
277
557
658
Continuity should exist.
Bank 1 Bank 2
A/F sensor 1 terminal ECM terminal A/F sensor 1 terminal ECM terminal 116176
275277
535557
656658
Continuity should not exist.
DTC P0130, P0150 A/F SENSOR 1 EC-909
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Removal and InstallationNBS004KM
AIR FUEL RATIO (A/F) SENSOR 1
Refer to EM-183, "EXHAUST MANIFOLD AND THREE WAY CATALYST" .
EC-910
[VK45DE]
DTC P0131, P0151 A/F SENSOR 1
Revision: 2006 December 2006 FX35/FX45
DTC P0131, P0151 A/F SENSOR 1PFP:22693
Component DescriptionNBS004KN
The air fuel ratio (A/F) sensor 1 is a planar dual-cell limit current sen-
sor. The sensor element of the A/F sensor 1 is the combination of a
Nernst concentration cell (sensor cell) with an oxygen-pump cell,
which transports ions. It has a heater in the element.
The sensor is capable of precise measurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range (0.7 < < air).
The exhaust gas components diffuse through the diffusion gap at the
electrode of the oxygen pump and Nernst concentration cell, where
they are brought to thermodynamic balance.
An electronic circuit controls the pump current through the oxygen-
pump cell so that the composition of the exhaust gas in the diffusion
gap remains constant at = 1. Therefore, the A/F sensor 1 is able to
indicate air/fuel ratio by this pumping of current. In addition, a heater
is integrated in the sensor to ensure the required operating tempera-
ture of 700 - 800 °C (1,292 - 1,472 °F).
CONSULT-II Reference Value in Data Monitor ModeNBS004KO
Specification data are reference values.
On Board Diagnosis LogicNBS004KP
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the A/F sensor 1
signal is not inordinately low.
SEF579Z
SEF580Z
MONITOR ITEM CONDITION SPECIFICATION
A/F SEN1 (B1)
A/F SEN1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm Fluctuates around 1.5 V
DTC No. Trouble diagnosis name DTC detecting condition Possible Cause
P0131
0131
(Bank 1) Air fuel ratio (A/F) sensor 1
circuit low voltage The A/F signal computed by ECM from the A/F
sensor 1 signal is constantly approx. 0V.
Harness or connectors
(The A/F sensor 1 circuit is open or
shorted.)
A/F sensor 1
P0151
0151
(Bank 2)