Page 1426 of 4462
![INFINITI FX35 2006 Service Manual EC-42
[VQ35DE]
EVAPORATIVE EMISSION SYSTEM
Revision: 2006 December 2006 FX35/FX45
Component InspectionNBS003LB
EVAP CANISTER
Check EVAP canister as follows:
1. Block port B .
2. Blow air into port INFINITI FX35 2006 Service Manual EC-42
[VQ35DE]
EVAPORATIVE EMISSION SYSTEM
Revision: 2006 December 2006 FX35/FX45
Component InspectionNBS003LB
EVAP CANISTER
Check EVAP canister as follows:
1. Block port B .
2. Blow air into port](/manual-img/42/57019/w960_57019-1425.png)
EC-42
[VQ35DE]
EVAPORATIVE EMISSION SYSTEM
Revision: 2006 December 2006 FX35/FX45
Component InspectionNBS003LB
EVAP CANISTER
Check EVAP canister as follows:
1. Block port B .
2. Blow air into port A and check that it flows freely out of port C .
3. Release blocked port B .
4. Apply vacuum pressure to port B and check that vacuum pres-
sure exists at the ports A and C .
5. Block port A and B .
6. Apply pressure to port C and check that there is no leakage.
FUEL TANK VACUUM RELIEF VALVE (BUILT INTO FUEL FILLER CAP)
1. Wipe clean valve housing.
2. Check valve opening pressure and vacuum.
3. If out of specification, replace fuel filler cap as an assembly.
CAUTION:
Use only a genuine fuel filler cap as a replacement. If an incor-
rect fuel filler cap is used, the MIL may come on.
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EC-410, "Component Inspection" .
FUEL TANK TEMPERATURE SENSOR
Refer to EC-333, "Component Inspection" .
EVAP CANISTER VENT CONTROL VALVE
Refer to EC-417, "Component Inspection" .
EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC-433, "Component Inspection" .
PBIB1044E
SEF445Y
Pressure:
15.3 - 20.0 kPa (0.156 - 0.204 kg/cm2 , 2.22
- 2.90 psi)
Va c u u m : − 6.0 to −3.3 kPa ( −0.061 to −0.034 kg/cm
2 ,
− 0.87 to −0.48 psi)
SEF943S
Page 1427 of 4462
EVAPORATIVE EMISSION SYSTEM EC-43
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
EVAP SERVICE PORT
Positive pressure is delivered to the EVAP system through the EVAP
service port. If fuel vapor leakage in the EVAP system occurs, use a
leak detector to locate the leak.
Removal and InstallationNBS003LC
EVAP CANISTER
Tighten EVAP canister as shown in the figure.
EVAP CANISTER VENT CONTROL VALVE
1. Turn EVAP canister vent control valve counterclockwise.
2. Remove the EVAP canister vent control valve.
Always replace O-ring with a new one.
How to Detect Fuel Vapor LeakageNBS003LD
CAUTION:
Never use compressed air or a high pressure pump.
Do not exceed 4.12 kPa (0.042 kg/cm2 , 0.6 psi) of pressure in EVAP system.
NOTE:
Do not start engine.
Improper installation of EVAP service port adapter to the EVAP service port may cause a leak.
SEF462UA
PBIB1029E
PBIB1030E
Page 1430 of 4462
![INFINITI FX35 2006 Service Manual EC-46
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
ON BOARD REFUELING VAPOR RECOVERY (ORVR)PFP:00032
System DescriptionNBS003LE
From the beginning of refuel INFINITI FX35 2006 Service Manual EC-46
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
ON BOARD REFUELING VAPOR RECOVERY (ORVR)PFP:00032
System DescriptionNBS003LE
From the beginning of refuel](/manual-img/42/57019/w960_57019-1429.png)
EC-46
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
ON BOARD REFUELING VAPOR RECOVERY (ORVR)PFP:00032
System DescriptionNBS003LE
From the beginning of refueling, the air and vapor inside the fuel tank go through refueling EVAP vapor cut
valve and EVAP/ORVR line to the EVAP canister. The vapor is absorbed by the EVAP canister and the air is
released to the atmosphere.
When the refueling has reached the full level of the fuel tank, the refueling EVAP vapor cut valve is closed and
refueling is stopped because of auto shut-off. The vapor which was absorbed by the EVAP canister is purged
during driving.
WARNING:
When conducting inspections below, be sure to observe the following:
Put a “CAUTION: FLAMMABLE” sign in workshop.
Do not smoke while servicing fuel system. Keep open flames and sparks away from work area.
Be sure to furnish the workshop with a CO2 fire extinguisher.
CAUTION:
Before removing fuel line parts, carry out the following procedures:
–Put drained fuel in an explosion-proof container and put lid on securely.
–Release fuel pressure from fuel line. Refer to EC-86, "FUEL PRESSURE RELEASE" .
–Disconnect battery ground cable.
Always replace O-ring when the fuel gauge retainer is removed.
Do not kink or twist hose and tube when they are installed.
Do not tighten hose and clamps excessively to avoid damaging hoses.
After installation, run engine and check for fuel leaks at connection.
Do not attempt to top off the fuel tank after the fuel pump nozzle shuts off automatically.
Continued refueling may cause fuel overflow, resulting in fuel spray and possibly a fire.
PBIB1068E
Page 1431 of 4462
![INFINITI FX35 2006 Service Manual ON BOARD REFUELING VAPOR RECOVERY (ORVR) EC-47
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS003LF
SYMPTOM: FUEL ODOR FROM EVAP CANISTER INFINITI FX35 2006 Service Manual ON BOARD REFUELING VAPOR RECOVERY (ORVR) EC-47
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS003LF
SYMPTOM: FUEL ODOR FROM EVAP CANISTER](/manual-img/42/57019/w960_57019-1430.png)
ON BOARD REFUELING VAPOR RECOVERY (ORVR) EC-47
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS003LF
SYMPTOM: FUEL ODOR FROM EVAP CANISTER IS STRONG.
1. CHECK EVAP CANISTER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
2. Weigh the EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
The weight should be less than 2.1 kg (4.6 lb).
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. CHECK IF EVAP CANISTER SATURATED WITH WATER
Does water drain from the EVAP canister?
Ye s o r N o
Ye s > > G O T O 3 .
No >> GO TO 5.
3. REPLACE EVAP CANISTER
Replace EVAP canister with a new one.
>> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the EVAP hose between EVAP canister and vehicle frame for clogging or poor connection.
>> Repair or replace EVAP hose.
5. CHECK REFUELING EVAP VAPOR CUT VALVE
Refer to EC-49, "
Component Inspection" .
OK or NG
OK >> INSPECTION END
NG >> Replace refueling EVAP vapor cut valve with fuel tank.
PBIB1031E
Page 1432 of 4462
![INFINITI FX35 2006 Service Manual EC-48
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
SYMPTOM: CANNOT REFUEL/FUEL ODOR FROM THE FUEL FILLER OPENING IS STRONG
WHILE REFUELING.
1. CHECK EVAP INFINITI FX35 2006 Service Manual EC-48
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
SYMPTOM: CANNOT REFUEL/FUEL ODOR FROM THE FUEL FILLER OPENING IS STRONG
WHILE REFUELING.
1. CHECK EVAP](/manual-img/42/57019/w960_57019-1431.png)
EC-48
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
SYMPTOM: CANNOT REFUEL/FUEL ODOR FROM THE FUEL FILLER OPENING IS STRONG
WHILE REFUELING.
1. CHECK EVAP CANISTER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
2. Weigh the EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
The weight should be less than 2.1 kg (4.6 lb).
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. CHECK IF EVAP CANISTER SATURATED WITH WATER
Does water drain from the EVAP canister?
Ye s o r N o
Yes >> GO TO 3.
No >> GO TO 5.
3. REPLACE EVAP CANISTER
Replace EVAP canister with a new one.
>> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the EVAP hose between EVAP canister and vehicle frame for clogging or poor connection.
>> Repair or replace EVAP hose.
5. CHECK VENT HOSES AND VENT TUBES
Check hoses and tubes between EVAP canister and refueling control valve for clogging, kink, looseness and
improper connection.
OK or NG
OK >> GO TO 6.
NG >> Repair or replace hoses and tubes.
6. CHECK FILLER NECK TUBE
Check recirculation line for clogging, dents and cracks.
OK or NG
OK >> GO TO 7.
NG >> Replace filler neck tube.
PBIB1031E
Page 1434 of 4462
![INFINITI FX35 2006 Service Manual EC-50
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
d. Apply vacuum pressure to hose end [ −13.3 kPa ( −100 mmHg, −3.94 inHg)] with fuel gauge retaine INFINITI FX35 2006 Service Manual EC-50
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
d. Apply vacuum pressure to hose end [ −13.3 kPa ( −100 mmHg, −3.94 inHg)] with fuel gauge retaine](/manual-img/42/57019/w960_57019-1433.png)
EC-50
[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Revision: 2006 December 2006 FX35/FX45
d. Apply vacuum pressure to hose end [ −13.3 kPa ( −100 mmHg, −3.94 inHg)] with fuel gauge retainer
remaining open and check that the pressure is applicable.
Without CONSULT-II
1. Remove fuel tank. Refer to FL-10, "FUEL TANK" .
2. Drain fuel from the tank as follows:
a. Remove fuel gauge retainer.
b. Drain fuel from the tank using a handy pump into a fuel container.
3. Check refueling EVAP vapor cut valve for being stuck to close as follows. Blow air into the refueling EVAP vapor cut valve (from the end of EVAP/ORVR line hose), and check that
the air flows freely into the tank.
4. Check refueling EVAP vapor cut valve for being stuck to open as follows.
a. Connect vacuum pump to hose end.
b. Remove fuel gauge retainer with fuel gauge unit. Always replace O-ring with new one.
c. Put fuel tank upside down.
d. Apply vacuum pressure to hose end [ −13.3 kPa ( −100 mmHg, −3.94 inHg)] with fuel gauge retainer
remaining open and check that the pressure is applicable.
PBIB1035E
PBIB1035E
Page 1470 of 4462
![INFINITI FX35 2006 Service Manual EC-86
[VQ35DE]
BASIC SERVICE PROCEDURE
Revision: 2006 December 2006 FX35/FX45
11. Wait 20 seconds.
12. Rev up the engine two or three times and make sure that idle speed and ignition timing are withi INFINITI FX35 2006 Service Manual EC-86
[VQ35DE]
BASIC SERVICE PROCEDURE
Revision: 2006 December 2006 FX35/FX45
11. Wait 20 seconds.
12. Rev up the engine two or three times and make sure that idle speed and ignition timing are withi](/manual-img/42/57019/w960_57019-1469.png)
EC-86
[VQ35DE]
BASIC SERVICE PROCEDURE
Revision: 2006 December 2006 FX35/FX45
11. Wait 20 seconds.
12. Rev up the engine two or three times and make sure that idle speed and ignition timing are within the specifications.
13. If idle speed and ignition timing are not within the specification, Idle Air Volume Learning will not be carried out successfully. In this case, find the cause of the incident by referring to the DIAGNOSTIC PROCE-
DURE below.
DIAGNOSTIC PROCEDURE
If idle air volume learning cannot be performed successfully, proceed as follows:
1. Check that throttle valve is fully closed.
2. Check PCV valve operation.
3. Check that downstream of throttle valve is free from air leakage.
4. When the above three items check out OK, engine component parts and their installation condi-
tion are questionable. Check and eliminate the cause of the incident.
It is useful to perform EC-138, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
5. If any of the following conditions occur after the engine has started, eliminate the cause of the
incident and perform Idle Air Volume Learning all over again:
Engine stalls.
Erroneous idle.
Fuel Pressure CheckNBS003LW
FUEL PRESSURE RELEASE
With CONSULT-II
1. Turn ignition switch ON.
2. Perform “FUEL PRESSURE RELEASE” in “WORK SUPPORT” mode with CONSULT-II.
3. Start engine.
4. After engine stalls, crank it two or three times to release all fuel pressure.
5. Turn ignition switch OFF.
ITEM SPECIFICATION
Idle speed 650 ± 50 rpm (in P or N position)
Ignition timing 15 ± 5 ° BTDC (in P or N position)
SEC897C
SEF214Y
Page 1471 of 4462
![INFINITI FX35 2006 Service Manual BASIC SERVICE PROCEDURE EC-87
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Without CONSULT-II
1. Remove fuel pump fuse located in IPDM E/R.
2. Start engine. INFINITI FX35 2006 Service Manual BASIC SERVICE PROCEDURE EC-87
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Without CONSULT-II
1. Remove fuel pump fuse located in IPDM E/R.
2. Start engine.](/manual-img/42/57019/w960_57019-1470.png)
BASIC SERVICE PROCEDURE EC-87
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Without CONSULT-II
1. Remove fuel pump fuse located in IPDM E/R.
2. Start engine.
3. After engine stalls, crank it two or three times to release all fuel pressure.
4. Turn ignition switch OFF.
5. Reinstall fuel pump fuse after servicing fuel system.
FUEL PRESSURE CHECK
CAUTION:
Before disconnecting fuel line, release fuel pressure from fuel line to eliminate danger.
NOTE:
Prepare pans or saucers under the disconnected fuel line because the fuel may spill out. The fuel
pressure cannot be completely released because S50 models do not have fuel return system.
Use Fuel Pressure Gauge Kit (J-44321) to check fuel pressure.
1. Release fuel pressure to zero. Refer to EC-86, "
FUEL PRESSURE RELEASE" .
2. Install the inline fuel quick disconnected fitting between fuel damper and fuel injector tube.
3. Connect the fuel pressure test gauge (quick connector adapter hose) to the inline fuel quick disconnected fitting.
4. Turn ignition switch ON and check for fuel leakage.
5. Start engine and check for fuel leakage.
6. Read the indication of fuel pressure gauge.
7. If result is unsatisfactory, go to next step.
8. Check the following.
Fuel hoses and fuel tubes for clogging
Fuel filter for clogging
Fuel pump
Fuel pressure regulator for clogging
If OK, replace fuel pressure regulator.
If NG, repair or replace.
PBIB1603E
At idling: Approximately 350 kPa (3.57 kg/cm2 , 51 psi)
PBIB1571E