TELEPHONE AV-191
C
D E
F
G H
I
J
L
M A
B
AV
Revision: 2006 December 2006 FX35/FX45
Removal and Installation of TEL Adapter UnitNKS003IV
REMOVAL
1. Remove instrument passenger lower panel. Refer to IP-10, "INSTRUMENT PANEL ASSEMBLY" .
2. Remove screws (A) with power tool and remove display control unit (1)and TEL adapter unit (2).
3. Remove TEL adapter unit screws, display control unit screws, and remove brackets.
INSTALLATION
Installation is the reverse order of removal.
Removal and Installation for TEL AntennaNKS003IW
REMOVAL
1. Remove TEL adapter unit, display control unit. Refer to AV- 1 9 1 , "Removal and Installation of TEL Adapter
Unit" .
2. Remove screws (A) and remove TEL antenna (1) from bracket.
INSTALLATION
Installation is the reverse order of removal.
Removal and Installation of MicrophoneNKS003IX
REMOVAL
1. Remove roof console. Refer to EI-42, "HEADLINING" .
2. Remove screws (A) and remove microphone (1) from roof con- sole.
INSTALLATION
Installation is the reverse order of removal.
SKIB8667E
SKIB8669E
SKIB8670E
BCM (BODY CONTROL MODULE) BCS-13
C
D E
F
G H
I
J
L
M A
B
BCS
Revision: 2006 December 2006 FX35/FX45
CONSULT-II Function (BCM)NKS00342
CONSULT-II can display each diagnostic item using the diagnostic test mode shown following.
CONSULT–II INSPECTION PROCEDURE
Refer to GI-38, "CONSULT-II Start Procedure" .
ITEMS OF EACH PART
NOTE:
CONSULT-II displays systems equipped in the vehicle.
× :Applicable
NOTE:
*1: This item is displayed, but should not be used.
*2: This item is displayed, but does not function. Diagnostic test item Check item, diagnostic test mode Content
Inspection by part WORK SUPPORT Changes setting of each function.
SELF-DIAG RESULTS BCM performs self-diagnosis of CAN communication.
DATA MONITOR Displays the input data of BCM in real time.
CAN DIAG SUPPORT MNTR The transmit/receive diagnosis result of CAN communication can be read.
ACTIVE TEST Gives a drive signal to a load to check the operation.
ECU PART NUMBER ECM part number can be read.
CONFIGURATION (Not be used)
System and item CONSULT-II display Diagnostic test mode (Inspection by part)
WORK
SUPPORT SELF
−
DIAG
RESULTS DATA
MONI- TOR CAN
DIAG SUP-
PORT
MNTR ACTIVE
TEST ECU
PA RT
NUM- BER CON-
FIGU-
RATION
BCM BCM ×× × ×
×
*1
Power door lock system DOOR LOCK ×××
Rear window defogger REAR DEFOGGER ××
Warning chime BUZZER ××
Room lamp timer INT LAMP ×××
Headlamp HEAD LAMP ×××
Wiper WIPER ×××
Turn signal lamp
Hazard lamp FLASHER
××
Blower fan switch signal
A/C switch signal AIR CONDITONER
×
Intelligent Key system INTELLIGENT KEY ×
Combination switch COMB SW ×
IVIS IMMU ××
Room lamp battery saver BATTERY SAVER ×× ×
Trunk lid TRUNK
*2××
Vehicle security system THEFT ALM ×××
Retained power control RETAINED PWR ×××
Oil pressure switch SIGNAL BUFFER ××
Low tire pressure warning
system AIR PRESSURE
MONITOR ××× ×
Panic system PANIC ALARM ×
BCS-14
BCM (BODY CONTROL MODULE)
Revision: 2006 December 2006 FX35/FX45
WORK SUPPORT
Operation Procedure
1. Touch “BCM” on “SELECT TEST ITEM” screen.
2. Touch “WORK SUPPORT” on “SELECT DIAG MODE” screen.
3. Touch item on “SELECT WORK ITEM” screen.
4. Touch “START”.
5. Touch “CHANGE SET”.
6. The setting will be changed and “RESETTING COMPLETED” will be displayed.
7. Touch “END”.
Display Item List
CAN Communication Inspection Using CONSULT-II (Self-Diagnosis)NKS00343
1. CHECK SELF-DIAGNOSTIC RESULT
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carry out CAN communication.
1. Connect to CONSULT-II, and select “BCM” on “SELECT SYSTEM” screen.
2. Select “BCM control unit ” on “SELECT WORK ITEM” screen, and select “SELF-DIAG RESULTS”.
3. Check display content in self-diagnostic results.
Contents displayed
No malfunction>>INSPECTION END
Malfunction in CAN communication system>>After printing the monitor items, go to “CAN System”. Refer to LAN-3, "
Precautions When Using CONSULT-II" .
Item Description
RESET SETTING VALUE Return a value set with WORK SUPPORT of each system to a default value in factory shipment.
CONSULT-II display code Diagnosis item
U1000 INITIAL DIAG
TRANSMIT DIAG ECM
IPDM E/R
METER/M&A I-KEY
POWER DOOR LOCK SYSTEM BL-23
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 December 2006 FX35/FX45
through grounds M35, M45 and M85.
Then key cylinder switch operation signal (unlock) is supplied
through power window main switch terminal 14.
to BCM terminal 22
BCM is connected to power window main switch and front power window switch (passenger side) as serial
link.
When the front door switch (driver side) is ON (door is OPEN), ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 1
through front door switch (driver side) case ground.
When the front door switch (passenger side) is ON (door is OPEN), ground is supplied
to BCM terminal 12
through front door switch (passenger side) terminal 1
through front door switch (passenger side) case ground.
When the rear door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 63
through front door switch LH terminal 1
through rear door switch LH case ground.
When the rear door switch RH is ON (door is OPEN), ground is supplied
to BCM terminal 13
through front door switch RH terminal 1
through rear door switch RH case ground.
When the back door switch is ON (door is OPEN), ground is supplied
to BCM terminal 58
through back door closure motor (door switch) terminal 7 and 8
through grounds B15 and B45.
OUTLINE
Functions Available by Operating the Door Lock and Unlock Switches on Driver's Door and
Passenger's Door
Interlocked with the locking operation of door lock and unlock switch, door lock actuators of all doors and
fuel lid lock actuator are locked.
Interlocked with the unlocking operation of door lock and unlock switch, door lock actuators of all doors
and fuel lid lock actuator are unlocked.
Functions Available by Operating the Key Cylinder Switch on Driver's
Interlocked with the locking operation of door key cylinder, door lock actuators of all doors and fuel lid lock
actuator are locked.
Select Unlock Operation
When door key cylinder is unlocked, door lock actuator driver side and fuel lid lock actuator are unlocked.
When door key cylinder is unlocked for the second time within 5 seconds after the first operation, door
lock actuators on all doors are unlocked.
Select unlock operation mode can be changed using “DOOR LOCK-UNLOCK SET” mode in “WORK
SUPPORT”. Refer to BL-37, "
Work Support" .
Select unlock operation mode can be changed also on the display.
Key Reminder Door System
When door lock and unlock switch is operated to lock doors with ignition key put in key cylinder and any door
open, all door lock actuators are locked and then unlocked.
Key reminder door mode can be changed using “WORK SUPPORT” mode in “ANTI-LOCK OUT SET”.
Refer to BL-37, "
Work Support" .
POWER DOOR LOCK SYSTEM BL-37
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 December 2006 FX35/FX45
Work FlowNIS001M4
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to BL-22, "
System Description" .
3. According to the trouble diagnosis chart by symptom, repair or replace the cause of the malfunction. Refer to BL-38, "
Trouble Diagnosis Chart by Symptom" .
4. Does power door lock system operate normally? YES: GO TO 5.
NO: GO TO 3.
5. INSPECTION END
CONSULT-II Function (BCM)NIS001M5
CONSULT-II can display each diagnostic item using the diagnostic test modes shown.
CONSULT-II START PROCEDURE
Refer to GI-38, "CONSULT-II Start Procedure" .
CONSULT-II APPLICATION ITEMS
Work Support
Data Monitor
*: With Intelligent Key system BCM diagnosis
test item Check item diagnosis test mode Content
Door lock DATA MONITOR Displays the input data of BCM real time.
ACTIVE TEST Gives a drive signal to a load to check the operation.
Work item Description
DOOR LOCK-UNLOCK SET Select unlock mode can be changed in this mode. Selects ON-OFF of select unlock mode.
ANTI-LOCK OUT SET Key reminder door mode can be changed in this mode. Selects ON-OFF of key reminder door
mode.
Monitor item Content
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEY ON SW Indicates [ON/OFF] condition of key switch.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from door lock and unlock switch.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from door lock and unlock switch.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch driver side.
DOOR SW-AS Indicates [ON/OFF] condition of front door switch passenger side.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door switch.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from key cylinder.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from key cylinder.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from key fob.
KEYLESS UNLOCK Indicates [ON/OFF] condition of unlock signal from key fob.
I-KEY LOCK* Indicates [ON/OFF] condition of lock signal from door request switch.
I-KEY UNLOCK* Indicates [ON/OFF] condition of unlock signal from door request switch.
BL-56
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 December 2006 FX35/FX45
room lamp and key ring illumination
OPERATED PROCEDURE
Power Door Lock Operation
BCM receives a LOCK signal from key fob. BCM locks all doors with input of LOCK signal from key fob.
When an UNLOCK signal is sent from key fob once, driver's door will be unlocked.
Then, if an UNLOCK signal is sent from key fob again within 5 seconds, all other door will be unlocked.
Power door lock operation mode can be changed using “DOOR LOCK-UNLOCK SET” mode in “WORK SUP-
PORT” of “POWER DOOR LOCK SYSTEM”.
Refer to BL-65, "
Work Support" .
Power door lock operation mode can be changed also on the display.
Hazard and Horn Reminder
When the doors are locked or unlocked by key fob, power is supplied to hazard warning lamp and lamp flash
as follows
LOCK operation: C mode (flash twice) or S mode (flash twice)
UNLOCK operation: C mode (flash once) or S mode (do not flash)
BCM outputs to IPDM E/R for horn reminder signal as DATA LINE (CAN H line and CAN L line).
The hazard and horn reminder has C mode (horn chirp mode) and S mode (non-horn chirp mode).
Operating function of hazard and horn reminder
Hazard and horn reminder do not operate if any door switch is ON (any door is OPEN).
How to change hazard and horn reminder mode
With CONSULT-II
Hazard and horn reminder can be changed using “MULTI ANSWER BACK SET” mode in “WORK SUPPORT”.
Refer to BL-65, "
Work Support" .
Without CONSULT-II
When LOCK and UNLOCK signals are sent from the key fob for more than 2 seconds at the same time, the
hazard and horn reminder mode is changed and hazard warning lamp flashes and horn sounds as follows:
Auto Door Lock Operation
Auto lock function signal is sent for operation when any of the following signals are not sent within 1 minute
after the unlock signal is sent from the key fob:
when door switch is turned ON for open.
when the key switch is turned ON.
when the lock signal is sent from the key fob.
Auto door lock mode can be changed using “AUTO LOCK SET” mode in “WORK SUPPORT”.
Refer to BL-65, "
Work Support" .
Auto door lock mode can be changed also on the display.
C mode S mode
Remote controller
operation Lock Unlock Lock Unlock
Hazard warning lamp
flash Twice Once Twice —
Horn sound Once — — —
SEL153WA
BL-64
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 December 2006 FX35/FX45
CONSULT-II Function (BCM)NIS001MP
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
*: Refer to LAN-3, "Precautions When Using CONSULT-II" .
CONSULT-II INSPECTION PROCEDURE
Refer to GI-38, "CONSULT-II Start Procedure" .
CONSULT-II APPLICATION ITEMS
Data Monitor
Active Test
BCM diagnosis position Inspection items and diagnosis mode Description
BCM C/U* Self-diagnosis results Carries out the self-diagnosis.
DATA MONITOR Displays the input data to BCM on real-time basis.
CAN DIAG SUPPORT MNTR Displays CAN communication system diagnosis, disabled
transmission status, and communication status of each unit
communicated with BCM.
MULTI REMOTE
ENT DATA MONITOR
Displays the input remote keyless entry system data to BCM
on real–time basis.
ACTIVE TEST Gives a drive to a load to check the operation.
WORK SUPPORT Changes the setting for each function.
Monitored Item Description
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEY ON SW Indicates [ON/OFF] condition of key switch.
ACC ON SW Indicates [ON/OFF] condition of ignition switch in ACC position.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from key fob.
KEYLWSS UNLOCK Indicates [ON/OFF] condition of unlock signal from key fob.
KEYLESS PANIC Indicates [ON/OFF] condition of panic signal from key fob.
KEYLESS TRUNK This is displayed even when it is not equipped.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch driver side.
DOOR SW-AS Indicates [ON/OFF] condition of door switch passenger side.
DOOR SW-RR Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door switch.
TRUNK OPN MNTR This is displayed even when it is not equipped.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from door lock and unlock switch.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from door lock and unlock switch.
RKE LCK-UNLOCK Indicates [ON/OFF] condition of simultaneous signal of lock and unlock from key fob.
RKE KEEP UNLK Indicates [ON/OFF] condition of unlock continuousness signal from key fob.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from door key cylinder switch.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from door key cylinder switch.
Test Item Description
FLASHER This test is able to check right hazard reminder operation. The right hazard lamp turns on when “ON” on CONSULT-II screen is touched.
POWER WINDOW DOWN This test is able to check power window open operation.
The front power windows activate for 10 seconds after “ON” on CONSULT-II screen is touched.
HORN This test is able to check panic alarm and horn reminder operations. The horn activate for 0.5 seconds after “ON” on CONSULT-II screen is touched.
REMOTE KEYLESS ENTRY SYSTEM BL-65
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 December 2006 FX35/FX45
Work Support
*: Perform this mode always in the state of C mode. Refer to BL-56, "Hazard and Horn Reminder" .
HORN CHIRP SET*
*: Perform this mode always in the state of C mode. Refer to BL-56, "Hazard and Horn Reminder" .
This mode can be changed also on the display.
HAZARD LAMP BACK SET*
*: Perform this mode always in the state of C mode. Refer to BL-56, "Hazard and Horn Reminder" .
This mode can be changed also on the display. DOOR LOCK This test is able to check door lock actuator operation.
The all door lock actuator are locked when “ALL LOCK” on CONSULT-II screen is touched.
The all door lock actuator are unlocked when “ALL UNLOCK” on CONSULT-II screen is touched.
The door lock actuator (driver side) is unlocked when “DR UNLOCK” on CONSULT-II screen is
touched.
The all door lock actuator (except driver side) are unlocked when “OTHER UNLOCK” on CON-
SULT-II screen is touched.
TRUNK/BACK DOOR This is displayed even when it is not equipped. Test Item Description
Test Item Description
HORN CHIRP SET* Horn reminder mode can be changed in this mode. The horn reminder mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched.
HAZARD LAMP SET* Hazard reminder mode can be changed in this mode. The hazard reminder mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched.
MULTI ANSWER BACK SET Hazard and horn reminder mode can be changed in this mode. The hazard and horn
reminder mode will be changed when “CHANGE SETT” on CONSULT-II screen is touched.
AUTO LOCK SET Auto locking function mode can be changed in this mode. The function mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched.
PANIC ALRM SET Panic alarm operation mode can be changed in this mode. The operation mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched.
PW DOWN SET Keyless power window down (open) operation mode can be changed in this mode. The
operation mode will be changed when“CHANGE SETT” on CONSULT-II screen is touched.
Horn chirp function ON OFF
MODE1 MODE2 MODE3 MODE4
Hazard lamp operation mode Nothing Unlock only Lock only Lock and Unlock