LT-92
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: 2006 December 2006 FX35/FX45
to grounds M35, M45 and M85
through hazard switch terminal 1.
When the hazard switch is depressed, BCM output turn signal from BCM terminals 45 and 46, interpreting it as
turn signal is ON.
Connected from BCM terminal 45 and 46 to front combination lamp RH and LH terminals 4.
Turn signal lamp turns ON
through front combination lamp RH and LH terminals 8
to grounds E21, E50 and E51.
Connected form BCM terminals 45 and 46 to rear combination lamp control unit terminals 4 and 5.
Rear turn signal (LED) turns ON
through rear combination lamp control unit terminal 11
to rear combination lamp LH terminal 3,
through rear combination lamp LH terminal 4
to rear combination lamp control unit terminal 10,
through rear combination lamp control unit terminal 9
to rear combination lamp RH terminal 3,
through rear combination lamp RH terminal 4
to rear combination lamp control unit terminal 8.
BCM sends signal to the unified meter and A/C amp. through CAN communication lines, and turns ON turn
signal indicator lamp with combination meter.
When rear turn signal lamp (LED) does not turn ON, rear combination lamp control unit sends signal to combi-
nation meter. And then unified meter and A/C amp. ends turn LED burnout status signal to BCM through CAN
communication lines for speeding up turn signal blinking.
REMOTE CONTROL ENTRY SYSTEM OPERATION
Power is supplied at all times
through 50A fusible link (letter M, located in fuse, fusible link and relay box)
to BCM terminal 55,
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8,
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1.
Ground is supplied
to BCM terminals 49 and 52
through grounds M35, M45 and M85,
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51,
to combination meter terminals 5, 6 and 15
through grounds M35, M45 and M85.
When the remote control entry system is triggered by input from key fob, BCM output turn signal from BCM
terminals 45 and 46, interpreting it as turn signal is ON.
Connected from BCM terminals 45 and 46 to front combination lamp RH and LH terminals 4.
Turn signal lamp turns ON
through front combination lamp RH and LH terminals 8
to grounds E21, E50 and E51.
Connected form BCM terminals 45 and 46 to rear combination lamp control unit terminals 4 and 5.
Rear turn signal (LED) turns ON
through rear combination lamp control unit terminal 11
to rear combination lamp LH terminal 3,
through rear combination lamp LH terminal 4
to rear combination lamp control unit terminal 10,
through rear combination lamp control unit terminal 9
LT-102
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: 2006 December 2006 FX35/FX45
How to Proceed With Trouble DiagnosisNKS002XJ
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 9 0 , "
System Description" .
3. Perform preliminary check. Refer to LT- 1 0 2 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Do turn signal and hazard warning lamps operate normally? If YES, GO TO 6. If NO, GO TO 4.
6. INSPECTION END
Preliminary CheckNKS002XK
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES
Check for blown fuses.
Refer to LT- 9 5 , "
Wiring Diagram — TURN —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
Unit Power source Fuse and fusible link No.
BCM Battery
M
22
Ignition switch ON or START position 1 Ignition switch ACC or ON position 6
Rear combination lamp control unit Battery 20
(+) (-) Ignition switch position
OFF ACC ON
BCM con-
nector Terminal
M3 11
Ground Approx. 0 V
Battery
voltage Battery
voltage
38 Approx. 0 V Approx. 0 V Battery
voltage
M4 42
Battery
voltage Battery
voltage Battery
voltage
55 Battery
voltage Battery
voltage Battery
voltage
PKIB5197E
LT-128
STOP LAMP
Revision: 2006 December 2006 FX35/FX45
Terminals and Reference Value for Rear Combination Lamp Control UnitNKS003N9
Refer to LT- 1 2 8 , "Terminals and Reference Value for Rear Combination Lamp Control Unit" .
Stop Lamp Does Not OperateNKS002Y6
1. CHECK TAIL LAMP AND TURN SIGNAL LAMP
Make sure tail lamps and turn signal lamps is illuminated.
OK or NG
OK >> GO TO 2.
NG >> GO TO 6.
2. CHECK FUSE
Check fuse No.20 is blow out.
OK or NG
OK >> GO TO 3.
NG >> If fuse is blow out, be sure to eliminate cause of problem before installing new fuse.
3. CHECK INPUT SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between rear combination lamp control unit har- ness connector and ground.
OK or NG
OK >> Replace rear combination lamp control unit.
NG >> GO TO 4.
4. CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Disconnect stop lamp switch connector.
2. Check voltage between stop lamp switch harness connector E210 terminal 1 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
(+)
(-) Condition Voltage
BCM con-
nector Terminal
B65 3 Ground Stop lamp switch is ON.
(Depressed) Battery
voltage
Stop lamp switch is OFF. (Released) Approx. 0 V
PKIA5233E
1 – Ground : Battery voltage.
PKIA5234E
PARKING, LICENSE PLATE AND TAIL LAMPS LT-133
C
D E
F
G H
I
J
L
M A
B
LT
Revision: 2006 December 2006 FX35/FX45
PARKING, LICENSE PLATE AND TAIL LAMPSPFP:26550
Component Parts and Harness Connector LocationNKS003GZ
System DescriptionNKS003H0
Control of the parking, license plate, side marker and tail lamp operation is dependent upon the position of the
lighting switch (combination switch). When the lighting switch is placed in the 1ST position, the BCM (body
control module) receives input signal requesting the parking, license plate, side marker and tail lamps to illumi-
nate. This input signal is communicated to the IPDM E/R (intelligent power distribution module engine room)
through the CAN communication lines. CPU (central processing unit) located in the IPDM E/R controls the tail
lamp relay coil. This relay, when energized, directs power to the parking, license plate, side marker and tail
lamps, which then illuminate.
The current that flows by Rear combination lamp control unit is controlled, and a tail lamp (LED) is made to
turn ON.
OUT LINE
Power is supplied at all times
through 10A fuse (No. 71, located in IPDM E/R)
to tail lamp relay, located in IPDM E/R and
to CPU located in IPDM E/R,
PKIC9694E
LT-134
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: 2006 December 2006 FX35/FX45
through 15A fuse (No. 78, located in IPDM E/R)
to CPU located in IPDM E/R.
Power is also supplied at all times
through 50A fusible link (letter M, located in fuse, fusible link and relay box)
to BCM terminal 55,
through 15A fuse [No. 22, located in fuse block (J/B)]
to BCM terminal 42,
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1,
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8 and
to unified meter and A/C amp. terminal 21.
With ignition switch in ON or START position, power is supplied
through ignition relay, located in IPDM E/R, from battery direct,
through 15A fuse [No. 1, located in fuse block (J/B)]
to BCM terminal 38,
through 10A fuse [No. 12, located in fuse block (J/B)]
to combination meter terminal 7 and
to unified meter and A/C amp. terminal 22.
With ignition switch in ACC or ON position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM terminal 11.
Ground is supplied
to BCM terminals 49 and 52
through grounds M35, M45 and M85,
to IPDM E/R terminals 38 and 60
through grounds E21, E50 and E51,
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51,
to combination meter terminals 5, 6 and 15
through grounds M35, M45 and M85,
to unified meter and A/C amp. terminals 29 and 30
through grounds M35, M45 and M85.
OPERATION BY LIGHTING SWITCH
With the lighting switch in the 1ST or 2ND position (or if the auto light system is activated), the BCM receives
input signal requesting the parking, license plate, side marker and tail lamps to illuminate. This input signal is
communicated to the IPDM E/R through the CAN communication lines. The CPU located in the IPDM E/R
controls the tail lamp relay coil, which when energized, directs power.
through IPDM E/R terminal 22
to front side marker lamp LH terminal 1
to parking lamp LH terminal 2
to license plate lamp LH terminal 1
to rear combination lamp LH terminal 1
to rear combination lamp control unit terminal 2
to front side marker lamp RH terminal 1
to parking lamp RH terminal 2
to license plate lamp RH terminal 1 and
to rear combination lamp RH terminal 1.
Ground is supplied at all times
LT-144
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: 2006 December 2006 FX35/FX45
Terminals and Reference Value for Rear Combination Lamp Control UnitNKS003NA
Refer to LT- 9 9 , "Terminals and Reference Value for Rear Combination Lamp Control Unit" .
How to Proceed With Trouble DiagnosisNKS003H7
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 1 3 3 , "
System Description" .
3. Perform Preliminary Check. Refer to LT- 1 4 4 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Do parking, license plate, side marker and tail lamps operate normally? If YES, GO TO 6. If NO, GO TO 4.
6. INSPECTION END
Preliminary CheckNKS003H8
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES
Check for blown fuses.
Refer to LT- 1 3 7 , "
Wiring Diagram — TAIL/L —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
Unit Power source Fuse and fusible link No.
BCM Battery
M
22
Ignition switch ON or START position 1 Ignition switch ACC or ON position 6
IPDM E/R Battery 71
Rear combination lamp control unit Battery 20
(+) (-) Ignition switch position
BCM con- nector Terminal OFF ACC ON
M3 11
Ground Approx. 0 V
Battery
voltage Battery
voltage
38 Approx. 0 V Approx. 0 V Battery
voltage
M4 42
Battery
voltage Battery
voltage Battery
voltage
55 Battery
voltage Battery
voltage Battery
voltage
PKIB5197E
INTERIOR ROOM LAMP LT-157
C
D E
F
G H
I
J
L
M A
B
LT
Revision: 2006 December 2006 FX35/FX45
When the room lamp and personal lamp turns ON, there is a gradual brightening over 1 second. When room
lamp and personal lamp turns OFF, there is a gradual dimming over 1 second.
The room lamp and personal lamp timer is controlled by the BCM (body control module).
Room lamp and personal lamp timer control settings can be changed with CONSULT-II.
Ignition keyhole illumination turns ON at time when driver door is opened (door switch ON) or removed keyfob
from key cylinder. Illumination turns OFF when driver door is closed (door switch OFF).
Step lamp turns ON at time when driver door or passenger door is opened (door switch ON). Lamp turns OFF
when the driver, passenger doors are closed (all door switches OFF).
POWER SUPPLY AND GROUND
Power is supplied at all times (without Intelligent Key system)
through 15A fuse [No. 22, located in fuse block (J/B)]
to key switch terminal 2 and
to BCM terminal 42,
through 50A fusible link (letter M, located in fuse, fusible link and relay box)
to BCM terminal 55,
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8.
Power is supplied at all times (with Intelligent Key system)
through 10A fuse (No.38, located in fuse, fusible link and relay box)
to key switch and ignition knob switch terminal 1,
through 15A fuse [No.22, located in fuse block (J/B)]
to BCM terminal 42 and
to key switch and ignition knob switch terminal 3,
through 50A fusible link (letter M, located in fuse, fusible link and relay box)
to BCM terminal 55,
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8.
When key plate inserted to key switch, power is supplied (without Intelligent Key system)
through key switch terminal 1
to BCM terminal 37.
When inserted key plate to key switch, power is supplied (with Intelligent Key system)
through key switch and ignition knob switch terminal 4
to BCM terminal 37.
When moved ignition knob switch, power is supplied (with Intelligent Key system)
through ignition knob switch terminal 2
to intelligent key unit terminal 27.
With ignition switch in the ON or START position, power is supplied
through 15A fuse [No. 1, located in fuse block (J/B)]
to BCM terminal 38.
Ground is supplied
to BCM terminals 49 and 52
through grounds terminals M35, M45 and M85.
When driver side door is opened, ground is supplied
through case ground of front door switch (driver side)
through front door switch (driver side) terminal 1
to BCM terminal 62.
When passenger side door is opened, ground is supplied
through case ground of front door switch (passenger side)
through front door switch (passenger side) terminal 1
to BCM terminal 12.
INTERIOR ROOM LAMP LT-159
C
D E
F
G H
I
J
L
M A
B
LT
Revision: 2006 December 2006 FX35/FX45
through grounds M35, M45 and M85
to map lamp terminal 1.
And power is supplied
from BCM terminal 41
to map lamp terminal 3.
When interior room lamp switch is ON, ground supplied (without DVD player)
through grounds M35, M45 and M85
to interior room lamp terminal 3.
And power is supplied (without DVD player)
from BCM terminal 41
to interior room lamp terminal 2.
When personal lamp LH or RH switch is ON, ground supplied
through grounds M35, M45 and M85
to personal lamp LH or RH terminal 3.
And power is supplied
from BCM terminal 41
to personal lamp LH or RH terminal 2.
When vanity mirror lamp (driver side or passenger side) is ON, ground is supplied
through grounds M35, M45 and M85
to vanity mirror lamp (driver side or passenger side) terminal 2.
And power is supplied
from BCM terminal 41
to vanity mirror lamp (driver side or passenger side) terminal 1.
When luggage room lamp (back door side) is ON, ground is supplied
through grounds B15 and B45
to luggage room lamp (back door side) terminal 3.
And power is supplied
from BCM terminal 41
to luggage room lamp (back door side) terminals 2.
ROOM LAMP TIMER OPERATION
Without Intelligent Key System
When the interior room lamp and map lamp switch is in DOOR position, and when all conditions below are
met, BCM performs timer control (maximum 30 seconds) for interior room lamp and map lamp ON/OFF.
In addition, when spot turns ON or OFF there is gradual brightening or dimming over 1 second.
Power is supplied
to 15A fuse [No. 22, located infuse block (J/B)]
through key switch terminal 2.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
Ground is supplied
from BCM terminal 22
to power window main switch (door lock and unlock switch) terminal 14.
At the time that driver door are opened, BCM detects that driver door is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns interior room lamp and map lamp ON
for 30 seconds.
Key is in ignition key cylinder (key switch ON),
Power is supplied
through key switch terminal 1
to BCM terminal 37.