Page 316 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-316
INSPECTION PROCEDURE I-3: Flasher Timer: One of the turn-signal lamps does not illuminate.
.
TECHNICAL DESCRIPTION (COMMENT)
If the right or left turn-signal lamp does not illuminate,
their bulb may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The turn-signal lamp bulb may be defective
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
.
Page 335 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-335
NOTE: Also check junction block connector C-204 for loose,
corroded, or damaged terminals, or terminals pushed back in
the connector. If junction block connector C-204 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection P.00E-2.
Q: Is the wiring harness between rear combination lamp
(RH) connector F-03 (terminal 5) and ETACS-ECU
connector C-219 (terminal 9) in good condition?
YES : Replace the rear combination lamp socket assembly
(RH). Verify that the turn-signal lamps illuminate
normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the turn-signal lamps illuminate normally.
INSPECTION PROCEDURE I-4: The turn-signal lamp indicator does not illuminate normally.
NOTE: This troubleshooting procedure requires the
use of Diagnostic Tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
At the same time that the turn-signal lamps are illu-
minated, the ETACS-ECU sends a signal to illumi-
nate the turn-signal lamp indicator via the CAN bus
line.
.
TECHNICAL DESCRIPTION (COMMENT)
If the turn-signal indicator does not illuminate nor-
mally, connector(s), wiring harness in the CAN bus
lines, the ETACS-ECU or the combination meter may
be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The combination meter may be defective
The ETACS-ECU may be defective
.
Page 339 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-339
FOG LAMP
GENERAL DESCRIPTION CONCERNING THE FOG LAMPSM1549021400216
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80The following ECUs affect the functions and control
of the fog lamps.
Fog lamp
The fog lamps will illuminate only when the fog lamp
switch is operated while the low-beam headlamps
are on.
The fog lamps will be switched off when any of the
following conditions is met. The fog lamps will also
be switched off automatically by headlamp automatic
shutoff function.
When the high-beam headlamps are switched
on, the fog lamps will be switched off. If the
low-beam headlamps are switched on again, the
fog lamps will illuminate again.
When the headlamp switch is turned off or the tail
lamps and headlamps are off, the fog lamps will
be switched off. If the low-beam headlamps are
switched on again, the fog lamps will not illumi-
nate again.
Fog lamp indicator
At the same time that the fog lamps are illuminated, the
ETACS-ECU sends a signal to illuminate the fog lamp indicator
via the CAN bus line. The combination meter receives the
transmitted signal and turns the fog lamp indicator on and off. FUNCTION CONTROL ECU
Fog lamp ETACS-ECU, front-ECU, column switch
Fog lamp indicator ETACS-ECU, column switch
Page 340 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-340
INSPECTION PROCEDURE J-1: Fog Light: Fog lamps do not illuminate when the fog lamp switch is
turned on.
NOTE: This troubleshooting procedure requires the
use of Diagnostic Tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU sends a fog lamp illumination
request signal ("LAMP ON" signal) to the
front-ECU when the fog lamp switch is turned on
while the headlamps are illuminating at low
beam.
Then the front-ECU switches on its relay to illumi-
nate the fog lamps.
.
TECHNICAL DESCRIPTION (COMMENT)
If the headlamps illuminate at low beam, the fog
lamp relay, the fog lamp switch, the front-ECU or the
ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The fog lamp relay may be defective
The front-ECU may be defective
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the headlamp (low-beam) operation.
Q: Do the headlamps illuminate at low beam normally?
YES : Go to Step 2.
NO : Refer to Inspection Procedure H-2 "The headlamps
(low-beam) do not illuminate normally P.54B-264."
Page 345 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-345
INSPECTION PROCEDURE J-2: Fog Light: Fog lamps do not go out when the headlamps (low-beam)
are turned off while the fog lamps are on.
.
TECHNICAL DESCRIPTION (COMMENT)
If the trouble above occurs, the front-ECU may be
defective.
.
TROUBLESHOOTING HINT
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The front-ECU may be defective
DIAGNOSIS
Replace the front-ECU.
The fog lamps should go out when the headlamps (low-beam)
are turned off while the fog lamps are on.
INSPECTION PROCEDURE J-3: Fog Light: One of the fog lamps does not illuminate.
.
TECHNICAL DESCRIPTION (COMMENT)
If one of the fog lamps does not illuminate, the fog
lamp relay or the fog lamp bulb may be defective. If
the fog lamp indicator lamp does not illuminate, the
combination meter may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The fog lamp bulb may be defective
.
DIAGNOSIS
Required Special Tool:
MB991223: Harness Set
Page 351 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-351
CIRCUIT OPERATION
At the same time that the fog lamps are illuminated,
the ETACS-ECU sends a signal to illuminate the fog
lamp indicator via the CAN bus line.
.
TECHNICAL DESCRIPTION (COMMENT)
If the fog lamp indicator does not illuminate normally,
connector(s), wiring harness in the CAN bus lines,
the ETACS-ECU or the combination meter may be
defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The combination meter may be defective
The ETACS-ECU may be defective
.
Page 355 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-355
54B
INTERIOR LAMP
GENERAL DESCRIPTION CONCERNING THE INTERIOR LAMPM1549021800236
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80The following ECUs affect the functions and control
of the interior lamps.
Interior lamp control function
The ETACS-ECU controls the interior lamps by turn-
ing them on and off in the following way:
When a door is opened with the ignition switch
off, the interior lamps up to a luminance of 100
percent. When a door is closed, the interior lamps
dims at a luminance of 65 percent, and goes off
30 seconds later. However if the ignition switch is
turned ON or if a door is locked while the interior
lamps is dimming, the dome lamp will go off at
that point.
When a door is opened with the ignition switch
ON, the interior lamps up at a luminance of 100
percent. When a door is closed, the interior lamps
go off.
When the ignition key is removed with all doors
closed, the interior lamps up at a luminance of
100 percent, and goes off 30 seconds later. How-
ever if the ignition key is inserted again or if a
door is locked while the interior lamps is lighting,
the interior lamps will go off at that point.
To check keyless entry operations more easily,
the interior lamps is flashed once when the doors
are locked. When the doors are unlocked, the
interior lamps at a luminance of 100 percent, and
go off 15 seconds later.
NOTE: The dimmer function can be customised on
vehicles equipped with a multi center display (middle
grade type). Refer to P.54B-486.
NOTE: The dotted lines indicate that lighting mode
when the ignition switch is turned ON, door is locked,
or any door is opened during the timer illumination
time. FUNCTION CONTROL ECU
Interior lamp control function ETACS-ECU
Interior lamp automatic-shutoff function ETACS-ECU
Ignition key hole illumination lamp function ETACS-ECU
Door ajar indicator ETACS-ECU
Seat belt indicator ETACS-ECU
Page 359 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-359
INSPECTION PROCEDURE K-1: Interior Light: The dome lamp do not illuminate and go out normally.
NOTE: This troubleshooting procedure requires the
use of diagnostic tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU operates the dome lamp according
to the following signals:
Ignition switch (IG1): ON or OFF
Key reminder switch: ON or OFF
Door switches: ON or OFF
Driver’s door lock actuator switch: ON or OFF
Interior lamp loaded signal: ON
.
TECHNICAL DESCRIPTION (COMMENT)
If the dome lamp does not illuminate normally, a
burned-out dome lamp bulb, the input circuits from
the switches described in "CIRCUIT OPERATION",
the power supply line to the switches or the
ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector