MITSUBISHI 380 2005  Workshop Manual AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-82
STEP 11. Measure the voltage at A/C compressor clutch 
relay connector B-18X. 
The top and bottom of the A/C compressor connector are

Page 784 of 1500

MITSUBISHI 380 2005  Workshop Manual AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-83
NOTE: Also check intermediate connector A-13 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the 
connector. I

Page 785 of 1500

MITSUBISHI 380 2005  Workshop Manual AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-84
STEP 14. Check the wiring harness between powertrain 
control module connector B-20 (terminal 6) and A/C 
compressor clutch relay conne

Page 786 of 1500

MITSUBISHI 380 2005  Workshop Manual AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-85
STEP 16. Measure the voltage at A/C-ECU connector C-15. 
(1) Disconnect A/C-ECU connector C-15 and measure the 
voltage at the relay bo

Page 787 of 1500

MITSUBISHI 380 2005  Workshop Manual AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-86
STEP 17. Check the wiring harness between A/C 
compressor clutch relay connector B-18X (terminal 4) and 
A/C-ECU connector C-15 (termin

Page 790 of 1500

MITSUBISHI 380 2005  Workshop Manual AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-89
INSPECTION PROCEDURE 5: Front Blower Fan and Motor do not Turn.
.
CIRCUIT OPERATION
If the blower motor does not operate, the blower 
r

Page 792 of 1500

MITSUBISHI 380 2005  Workshop Manual AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-91
STEP 2. Measure the voltage at blower motor connector 
C-115. 
(1) Disconnect blower motor connector C-115, and measure 
the voltage at

Page 793 of 1500

MITSUBISHI 380 2005  Workshop Manual AUTO A/C DIAGNOSIS
HEATER, AIR CONDITIONING AND VENTILATION55-92
STEP 4. Check the blower relay continuity.
Follow the table below to check the blower relay for continuity.
Q: Is the blower relay cont