Page 830 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-63
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Door Switch CheckEIS008QA
1. CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT-II
Check door switches ("DOOR SW-DR", "DOOR SW-AS", "DOOR SW-RL", "DOOR SW-RR", "BACK DOOR
SW") in DATA MONITOR mode with CONSULT–II.Refer to BL-27, "
DATA MONITOR" .
When doors are open:
When doors are closed:
Without CONSULT-II
Check voltage between BCM connector M18 or M19 terminals 12,
13, 43, 47, 48 and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2.DOOR SW-DR : ON
DOOR SW-AS : ON
DOOR SW-RL : ON
DOOR SW-RR : ON
BACK DOOR SW : ON
DOOR SW-DR : OFF
DOOR SW-AS : OFF
DOOR SW-RL : OFF
DOOR SW-RR : OFF
BACK DOOR SW : OFF
LIIA0665E
Connector ItemTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M19Back door
latch (door
ajar switch)43
GroundOpen
↓
Closed0
↓
Battery voltage Front door
switch LH47
Rear door
switch LH48
M18Front door
switch RH12
Rear door
switch RH13
LIIA1041E
Page 831 of 3419

BL-64
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
2. CHECK DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM.
3. Check continuity between door switch connector (B) B8 (front LH), B108 (front RH), B18 (rear LH), B116
(rear RH) terminal 2 or back door latch connector (C) D503 terminal 7 and BCM connectors (A) M18, M19
terminals 12, 13, 43, 47 and 48.
4. Check continuity between door switch connector (B) B8 (front
LH), B108 (front RH), B18 (rear LH), B116 (rear RH) terminal 2
or back door latch connector (C) D503 terminal 7 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK DOOR SWITCHES
FRONT AND REAR DOORS
Check continuity between front or rear door switch terminal 2 and
exposed metal of switch while pressing and releasing switch.
BACK DOOR
Check continuity between back door latch connector (A) D503 termi-
nals 7 and 8 while pressing (closing back door) and releasing (open-
ing back door) switch.
OK or NG
OK >> (Front and rear doors) Switch circuit is OK.
OK >> (Back door) GO TO 4.
NG >> Replace door switch.2 - 12 : Continuity should exist.
2 - 13 : Continuity should exist.
2 - 47 : Continuity should exist.
2 - 48 : Continuity should exist.
7 - 43 : Continuity should exist.
2 - Ground : Continuity should not exist.
7 - Ground : Continuity should not exist.
WIIA0750E
Door switch is released : Continuity should exist.
Door switch is pushed : Continuity should not exist.
WIIA0644E
When back door is open : Continuity should exist.
When back door is closed : Continuity should not exist.
WIIA0752E
Page 832 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-65
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
4. CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Keyfob Battery and Function CheckEIS008QB
1. CHECK KEYFOB BATTERY
Remove battery and measure voltage across battery positive and negative terminals, (+) and (−).
NOTE:
Keyfob does not function if battery is not set correctly.
OK or NG
OK >> GO TO 2.
NG >> Replace battery.8 - Ground : Continuity should exist.
LIIA0828E
Voltage : 2.5V - 3.0V
SEL237W
Page 833 of 3419

BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
2. CHECK KEYFOB FUNCTION
With CONSULT-II
Check keyfob function in “DATA MONITOR” mode with CONSULT-II.
When pushing each button of keyfob, the corresponding monitor item should
be turned as follows.
Without CONSULT-II
Check keyfob function using Remote Keyless Entry Tester J-43241.
OK or NG
OK >> WITH CONSULT-II: Keyfob, remote keyless entry receiver and wiring harness between BCM and
remote keyless entry receiver are OK. Replace BCM. Refer to BCS-20, "
Removal and Installation
of BCM" .
OK >> WITHOUT CONSULT-II: Keyfob is OK. Further inspection is necessary. Refer to BL-60, "
SYMP-
TOM CHART" .
NG >> WITH CONSULT-II: Further inspection is necessary. Refer to BL-60, "
SYMPTOM CHART" .
NG >> WITHOUT CONSULT-II: Replace keyfob. Refer to BL-71, "
ID Code Entry Procedure" .
Remote Keyless Entry Receiver System CheckEIS008QC
1. REMOTE KEYLESS ENTRY RECEIVER SIGNAL
Check signal voltage waveform between BCM connector M18 termi-
nal 20 and ground using an oscilloscope.
OK or NG
OK >> Remote keyless entry receiver signal power supply, ground and signal circuits are OK. Replace
BCM. Refer to BCS-20, "
Removal and Installation of BCM" .
NG >> GO TO 2.Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCKRKE KEEP UNLK
turns to ON 3 seconds
after UNLOCK button
is pushed.
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK
at the same timeRKE LCK-UNLCK : ON
Pushing Power Back Door KEYLESS PBD : ON
LIIA1487E
Condition:
Keyfob buttons released : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .
Keyfob buttons pressed : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .LIIA1275E
Page 834 of 3419

REMOTE KEYLESS ENTRY SYSTEM
BL-67
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
2. REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY INSPECTION
Check signal voltage waveform between BCM connector M18 termi-
nal 19 and ground using an oscilloscope.
OK or NG
OK >> GO TO 3.
NG >> Replace BCM. Refer to BCS-20, "
Removal and Installa-
tion of BCM" .
3. REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT INSPECTION (BCM)
Check continuity between BCM connector M18 terminal 18 and
ground.
OK or NG
OK >> GO TO 4.
NG >> Replace BCM. Refer to BCS-20, "
Removal and Installa-
tion of BCM" .
4. HARNESS INSPECTION BETWEEN BCM AND REMOTE KEYLESS ENTRY RECEIVER
1. Disconnect remote keyless entry receiver and BCM connectors.
2. Check continuity between remote keyless entry receiver con-
nector M120 terminals 1, 2, 4 and BCM connector M18 termi-
nals 18, 19, 20.
3. Check continuity between remote keyless entry receiver termi-
nals 1, 2 and 4 and ground.
OK or NG
OK >> Replace remote keyless entry receiver.
NG >> Repair or replace harness.19 - Ground : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .
WIIA0433E
18 - Ground : Continuity should exist.
WIIA0434E
1 - 18 : Continuity should exist.
2 - 20 : Continuity should exist.
4 - 19 : Continuity should exist.
1 - Ground : Continuity should not exist.
2 - Ground : Continuity should not exist.
4 - Ground : Continuity should not exist.
WIIA0308E
Page 835 of 3419
BL-68
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
ACC Power CheckEIS008QD
1. CHECK ACC POWER
With CONSULT-II
Check "ACC ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONITOR" .
Without CONSULT-II
Check voltage between BCM connector M18 terminal 11 and
ground.
OK or NG
OK >> ACC power circuit is OK.
NG >> Check the following:
10A fuse [No. 4, located in fuse block (J/B)]
Harness for open or short.
IPDM E/R Operation CheckEIS008QE
1. CHECK IPDM E/R INPUT VOLTAGE
Check voltage between IPDM E/R connector E122 terminal 45 and
ground.
OK or NG
OK >> Replace IPDM E/R.
NG >> GO TO 2.
Monitor Item Condition
ACC ON SWIgnition switch position ACC : ON
Ignition switch position OFF : OFF
PIIA3367E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M18 11 GroundACC Battery voltage
OFF 0
PIIA7002E
ConnectorTe r m i n a l s
Voltage (V)
(Approx.)
(+) (–)
E122 45 Ground Battery voltage
LIIA1053E
Page 836 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-69
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
2. CHECK IPDM E/R INPUT VOLTAGE
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R and horn relay.
3. Check continuity between IPDM E/R connector E122 terminal
45 and horn relay connector H-1 terminal 1.
4. Check continuity between IPDM E/R connector E122 terminal
45 and ground.
OK or NG
OK >> Further inspection is necessary. Refer to BL-60, "SYMP-
TOM CHART" .
NG >> Repair or replace harness45 - 1 : Continuity should exist.
45 - Ground : Continuity should not exist.WIIA0679E
Page 837 of 3419

BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
Check Hazard FunctionEIS008QF
1. CHECK HAZARD WARNING LAMP
Does hazard indicator flash with hazard switch?
Ye s o r N o
Yes >> Hazard warning lamp circuit is OK.
No >> Check hazard indicator. Refer to LT- 8 0 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Check Horn FunctionEIS008QG
First, perform the "SELF-DIAG RESULTS" in "BCM" with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated in "SELF-DIAG RESULTS" of "BCM".
1. CHECK HORN FUNCTION
Does horn sound with horn switch?
Ye s o r N o
Yes >> Horn circuit is OK.
No >> Check horn circuit. Refer to WW-58, "
HORN" .
Check Headlamp FunctionEIS008QH
First, perform the "SELF-DIAG RESULTS" in "BCM" with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated in "SELF-DIAG RESULTS" of "BCM".
1. CHECK HEADLAMP OPERATION
Does headlamp come on when turning lighting switch ON?
Ye s o r N o
Yes >> Headlamp operation circuit is OK.
No >> Check headlamp circuit. Refer to LT- 6 , "
HEADLAMP (FOR USA)" .
Check Map Lamp Illumination FunctionEIS008QI
1. CHECK MAP LAMP ILLUMINATION FUNCTION
When map lamp switch is in DOOR position, open the front door LH or RH.
OK or NG
OK >> System is OK.
NG >> Check map lamp illumination circuit. Refer to LT- 1 5 2 , "
ILLUMINATION" . Map lamp and ignition keyhole illumination should illuminate.