2005 INFINITI QX4 check engine

[x] Cancel search: check engine

Page 1550 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0456 EVAP CONTROL SYSTEM
EC-359
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
Overall Function CheckUBS00H5V
 WITH GST
Use this procedure to check the overall function of the EVAP ver

Page 1554 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0456 EVAP CONTROL SYSTEM
EC-363
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
9. CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control va

Page 1555 of 3419

INFINITI QX4 2005  Factory Service Manual EC-364Revision: October 2005
DTC P0456 EVAP CONTROL SYSTEM
2005 QX56
13. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
 Without CONSULT-II
1. Start engine and warm it up to normal

Page 1563 of 3419

INFINITI QX4 2005  Factory Service Manual EC-372Revision: October 2005
DTC P0500 VSS
2005 QX56
DTC P0500 VSSPFP:32702
DescriptionUBS00H6C
NOTE:
If DTC P0500 is displayed with DTC U1000 or U1001, first perform the trouble diagnosis for DTC U10

Page 1564 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0500 VSS
EC-373
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
2. Start engine.
3. Read vehicle speed sensor signal in Service $01 with GST.
The vehicle speed sensor on GST should be a

Page 1566 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0506 ISC SYSTEM
EC-375
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
Diagnostic ProcedureUBS00H6K
1. CHECK INTAKE AIR LEAK
1. Start engine and let it idle.
2. Listen for an intake air

Page 1568 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0507 ISC SYSTEM
EC-377
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
Diagnostic ProcedureUBS00H6O
1. CHECK PCV HOSE CONNECTION
Confirm that PCV hose is connected correctly.
OK or NG
O

Page 1571 of 3419

INFINITI QX4 2005  Factory Service Manual EC-380Revision: October 2005
DTC P0550 PSP SENSOR
2005 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when mea