DTC P1031, P1032, P1051, P1052 A/F SENSOR 1 HEATERPFP:22693
Descr

Page 1803 of 4731

INFINITI FX35 2005  Service Manual EC-410
[VQ35DE]
DTC P1031, P1032, P1051, P1052 A/F SENSOR 1 HEATER
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground. 
Pulse signal

Page 1804 of 4731

INFINITI FX35 2005  Service Manual DTC P1031, P1032, P1051, P1052 A/F SENSOR 1 HEATER EC-411
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2005 July  2005 FX
2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT 
1. D

Page 1806 of 4731

INFINITI FX35 2005  Service Manual DTC P1065 ECM POWER SUPPLY EC-413
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2005 July  2005 FX
DTC P1065 ECM POWER SUPPLYPFP:23710
Component DescriptionABS006SX
Battery voltage is supp

Page 1808 of 4731

INFINITI FX35 2005  Service Manual DTC P1065 ECM POWER SUPPLY EC-415
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2005 July  2005 FX
Specification data are reference values and are measured between each terminal and ground

Page 1809 of 4731

INFINITI FX35 2005  Service Manual EC-416
[VQ35DE]
DTC P1065 ECM POWER SUPPLY
Revision: 2005 July 2005 FX
4. PERFORM DTC CONFIRMATION PROCEDURE 
   With CONSULT-II 
1. Turn ignition switch ON.
2. Select “SELF DIAG RESULTS” mode wit

Page 1810 of 4731

INFINITI FX35 2005  Service Manual DTC P1111, P1136 IVT CONTROL SOLENOID VALVE EC-417
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2005 July  2005 FX
D T C  P 1111 ,  P 11 3 6  I V T  C O N T R O L  SO L E N O I D  VA LV E

Page 1814 of 4731

INFINITI FX35 2005  Service Manual DTC P1111, P1136 IVT CONTROL SOLENOID VALVE EC-421
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2005 July  2005 FX
Specification data are reference values and are measured between each te