INFINITI FX35 2005  Service Manual EC-1244
[VK45DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground. 
CAUTION: 
Do not use

Page 2639 of 4731

INFINITI FX35 2005  Service Manual EC-1246
[VK45DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
5. Perform “VENT CONTROL/V” in “ACTIVE TEST” mode. 
6. Check air passage continuity and operation delay

Page 2643 of 4731

INFINITI FX35 2005  Service Manual EC-1250
[VK45DE]
DTC P1564 ICC STEERING SWITCH
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground. 
CAUTION: 
Do not use ECM ground t

Page 2650 of 4731

INFINITI FX35 2005  Service Manual DTC P1564 ASCD STEERING SWITCH EC-1257
[VK45DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2005 July  2005 FX
Specification data are reference values and are measured between each terminal and g

Page 2659 of 4731

INFINITI FX35 2005  Service Manual EC-1266
[VK45DE]
DTC P1572 ICC BRAKE SWITCH
Revision: 2005 July 2005 FX
2. CHECK OVERALL FUNCTION-II 
 With CONSULT-II 
Check “BRAKE SW2” indication in “DATA MONITOR” mode.  
 Without CONSULT-

Page 2671 of 4731

INFINITI FX35 2005  Service Manual EC-1278
[VK45DE]
DTC P1572 ASCD BRAKE SWITCH
Revision: 2005 July 2005 FX
11 .  DETECT MALFUNCTIONING PART 
Check the following.
Harness connectors E211, M41
Harness for open or short between ECM and

Page 2679 of 4731

INFINITI FX35 2005  Service Manual EC-1286
[VK45DE]
DTC P1706 PNP SWITCH
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground. 
CAUTION: 
Do not use ECM ground terminals

Page 2687 of 4731

INFINITI FX35 2005  Service Manual EC-1294
[VK45DE]
DTC P1800 VIAS CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground. 
CAUTION: 
Do not use ECM