BL-64
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2005 July 2005 FX
Terminals and Reference Value for BCMAIS004MF
TERMI-
NAL WIRE
COLOR ITEM CONDITION VOLTAGE (V)
Approx.
1PU Key ring illumination output sig-
nal Key ring illumination is lighting. Battery voltage
Key ring illumination is being turned off. 0
11 LG/R Ignition switch Ignition switch is in ACC or ON position Battery voltage
12 P/B Front door switch (Passenger
side) ON (door open)
→ OFF (door closed) 0 → Battery voltage
13 P/L Rear door switch RH ON (door open) → OFF (door closed) 0 → Battery voltage
18 B Remote keyless entry receiver
(Ground) —0
19 R Remote keyless entry receiver
(Power supply) —
20 Y Remote keyless entry receiver
(Signal) Stand-by
When remote keyless entry receiver
receives signal from keyfob.
37 B/W Key switch ON (Key is inserted in IGN key cylinder)
→ OFF (Key is removed from IGN key
cylinder) Battery voltage
→ 0
38 W/L Ignition switch Ignition switch is in ON or START posi-
tion Battery voltage
39 L CAN H — —
40 R CAN L — —
41 R/B Battery saver output signal 30 minutes after ignition switch is turned
to OFF 0
Ignition switch is in ON position Battery voltage
42 L/R Battery power supply (fuse) — Battery voltage
44 Y Driver door lock actuator
(Unlock) Door lock / unlock switch
(Free → Unlock) 0
→ Battery voltage
45 G/W Left turn signal lamp When door lock or unlock is operated
using key fob.*
1
(ON → OFF) Battery voltage
→ 0
46 BR/W Right turn signal lamp When door lock or unlock is operated
using key fob.*
1
(ON → OFF) Battery voltage
→ 0
47 Y/R Step lamp output signal Step lamp is lighting. 0
Step lamp is being turned off. Battery voltage
OCC3881D
OCC3879D
OCC3880D
REMOTE KEYLESS ENTRY SYSTEM BL-65
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
*1 : In the state that hazard reminder operates.
*2 : In the state that room lamp switch is in “DOOR” position.
Terminals and Reference Value for IPDM E/RAIS004MG
* : In the state that horn reminder operates. 48 PU/W Room lamp output signal
Room lamp is lighting.*
20
Room lamp is being turned off.*
2Battery voltage
49, 52 B Ground — 0
50 PU Door lock actuator (Lock) Door lock / unlock switch
(Free → Lock) 0
→ Battery voltage
51 W/B Passenger and rear doors lock
actuator (Unlock) Door lock / unlock switch
(Free → Unlock) 0
→ Battery voltage
54 W Battery power supply
(power window) — Battery voltage
55 G Battery power supply (Fusible
link) — Battery voltage
58 L Back door switch OFF (Door close) → ON (Door open) 9 → 0
62 W Front door switch (Driver side) OFF (Door close) → ON (Door open) Battery voltage → 0
63 P Rear door switch LH OFF (Door close) → ON (Door open) Battery voltage → 0
TERMI-
NAL WIRE
COLOR ITEM CONDITION VOLTAGE (V)
Approx.
TERMINAL WIRE
COLOR ITEM CONDITION VOLTAGE (V)
Approx.
38 B Ground — 0
48 L CAN H — —
49 R CAN L — —
51 SB Horn relay When door lock is operated using key
fob* (OFF → ON) Battery voltage
→ 0
60 B Ground — 0
REMOTE KEYLESS ENTRY SYSTEM BL-83
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Check Hazard Warning Lamp FunctionAIS004MP
1. CHECK HAZARD WARNING LAMP
Do hazard warning lamp flash with hazard switch?
YES or NO
YES >> Hazard warning lamp circuit is OK.
NO >> Check hazard circuit. Refer to LT- 9 1 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Check Horn FunctionAIS004MQ
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-15, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HORN FUNCTION
Does horn sound with horn switch?
YES or NO
YES >> Horn circuit is OK.
NO >> Check horn circuit. Refer to WW-59, "
HORN" .
Check Headlamp FunctionAIS004MR
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-15, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HEADLAMP FUNCTION
Does headlamp come on when turning lighting switch “ON”?
YES or NO
YES >> Headlamp operation circuit is OK.
NO >> Check headlamp system. Refer to LT- 7 , "
HEADLAMP - XENON TYPE -" .
Check Map Lamp and Ignition Keyhole Illumination FunctionAIS004MS
1. CHECK MAP LAMP AND IGNITION KEYHOLE ILLUMINATION FUNCTION
When map lamp switch is in “DOOR” position, open the front door (LH or RH).
OK or NG
OK >> Replace BCM.
NG >> Check ignition illumination circuit. Refer to LT- 1 5 9 , "
INTERIOR ROOM LAMP" .
Map lamp and ignition keyhole illumination should illuminate.
BL-116
INTELLIGENT KEY SYSTEM
Revision: 2005 July 2005 FX
Terminals and Reference Value for Steering Lock unitAIS004N1
Terminals and Reference Value for BCMAIS004N2
Terminal
number Wire
color Item Condition
Voltage (V)
(Approx.)
Ignition knob
position Operation or conditions
1 L/R Power source (Fuse) LOCK — Battery voltage
2R/W Steering lock unit
power supply LOCK — 5
3R/B Steering lock unit com-
munication signal LOCK Press ignition knob with Intelligent
Key inside vehicle.
Other than the above 5
4Y/B Steering lock unit
ground —— 0
SIIA1911J
Te r m i -
nal Wire
color Item Condition Voltage (V)
(Approx.)
1PU Key ring illumination output sig-
nal Key ring illumination is lighting. Battery voltage
Key ring illumination is being turned off. 0
12 P/B Front door switch (Passenger
side) Door open (ON)
→ Close (OFF) 0 → Battery voltage
13 P/L Rear door switch RH Door open (ON) → Close (OFF) 0 → Battery voltage
37 B/W Key switch Insert mechanical key from ignition key
sylinder. Battery voltage
Remove mechanical key from ignition
key cylinder. 0
38 W/L Ignition switch (ON) Ignition switch is in ON or START posi-
tion Battery voltage
39 L CAN-H — —
40 R CAN-L — —
41 R/B Battery saver output signal 30 minutes after ignition switch is turned
to OFF 0
Ignition switch is in ON position Battery voltage
42 L/R Power source (Fuse) — Battery voltage
44 Y Driver door lock actuator
(Unlock) Door lock / unlock switch
(Free → Unlock) 0
→ Battery voltage
45 G/W Left turn signal lamp When door lock or unlock is operated
using Intelligent Key.*
1
(ON → OFF) Battery voltage
→ 0
46 BR/W Right turn signal lamp When door lock or unlock is operated
using Intelligent Key.*
1
(ON → OFF) Battery voltage
→ 0
47 Y/R Step lamp output signal Step lamp is lighting. 0
Step lamp is being turned off. Battery voltage
48 PU/W Room lamp output signal Room lamp is lighting.*
20
Room lamp is being turned off.*
2Battery voltage
49 B Ground — 0
BL-150
INTELLIGENT KEY SYSTEM
Revision: 2005 July 2005 FX
Check Hazard FunctionAIS004NP
1. CHECK HAZARD WARNING LAMP
Does hazard warning lamp flash with hazard switch?
YES or NO
YES >> Hazard warning lamp circuit is OK.
NO >> Check hazard circuit. Refer to LT- 9 1 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Check Horn FunctionAIS004NQ
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-15, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HORN FUNCTION
Does horn sound with horn switch?
YES or NO
YES >> Horn circuit is OK.
NO >> Check horn circuit. Refer to WW-59, "
HORN" .
Check Headlamp FunctionAIS004NR
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-15, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HEADLAMP OPERATION
Does headlamp come on when turning lighting switch “ON”?
YES or NO
YES >> Headlamp operation circuit is OK.
NO >> Check headlamp system. Refer to LT- 7 , "
HEADLAMP - XENON TYPE -" .
Check IPDM E/R OperationAIS004NS
1. CHECK IPDM E/R INPUT VOLTAGE
Check voltage between IPDM E/R connector E9 terminal 51 (SB) and ground.
OK or NG
OK >> Replace IPDM E/R.
NG >> GO TO 2. 51 (SB) – Ground : Battery voltage
PIIA6403E
VEHICLE SECURITY (THEFT WARNING) SYSTEM BL-199
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Terminals and Reference Value for IPDM E/RAIS004OZ
Terminal Wire color Item Condition Voltage (V)
(Approx.)
20 LG Headlamp low (RH) Lighting switch 2ND position
ON → OFF Battery voltage
→ 0
27 BR Headlamp high (RH) Lighting switch HIGH or PASS position
ON → OFF Battery voltage
→ 0
28 SB Headlamp high (LH) Lighting switch HIGH or PASS position
ON → OFF Battery voltage
→ 0
30 GY Headlamp low (LH) Lighting switch 2ND position
ON → OFF Battery voltage
→ 0
38 B Ground (power) — 0
48 L CAN-H — —
49 R CAN-L — —
51 SB Horn relay control signal Panic alarm is operating 0
Other than above Battery voltage
56 LG Hood switch signal ON (Open) → OFF (closed) 0 → Battery voltage
60 B Ground (signal) — 0
BL-212
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Revision: 2005 July 2005 FX
Diagnostic Procedure 3AIS004P6
FRONT DOOR KEY CYLINDER SWITCH CHECK
1. CHECK KEY CYLINDER SWITCH OPERATION
Check door key cylinder switch using key.
Do doors lock / unlock when using the key?
YES >> Front door key cylinder switch operation is OK.
NO >> Check door key cylinder switch circuit. Refer to GW-69, "
Front Door Key Cylinder Switch Check" .
Diagnostic Procedure 4AIS004P7
VEHICLE SECURITY HORN ALARM CHECK
1. CHECK HORN OPERATION
Check if horn sounds with horn switch.
Does horn operate?
YES >> Check harness for open or short between IPDM E/R and horn relay.
NO >> Check horn circuit. Refer to WW-59, "
HORN" .
Diagnostic Procedure 5AIS004P8
VEHICLE SECURITY HEADLAMP ALARM CHECK
1. CHECK HEADLAMP OPERATION
Check if headlamp operates by lighting switch.
Does headlamp come on when turning switch
“ON”?
YES >> Headlamp alarm circuit is OK.
NO >> Check headlamp system. Refer to LT- 7 , "
HEADLAMP - XENON TYPE -" or LT- 3 9 , "DAYTIME
LIGHT SYSTEM" .
Diagnostic Procedure 6AIS004P9
DOOR LOCK AND UNLOCK SWITCH CHECK
1. CHECK DOOR LOCK AND UNLOCK SWITCH INPUT SIGNAL
Check if power door lock operated by door lock and unlock switch.
Do doors lock / unlock when using each door lock and unlock switches?
YES >> Door lock and unlock switch is OK.
NO >> Check door lock and unlock switch. Refer to BL-48, "
Check Door Lock and Unlock Switch" .
IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS) BL-225
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Trouble Diagnosis Symptom ChartAIS004PK
*: When IVIS (NATS) detects trouble, the security indicator lights up while electronic key is in the “ON” position.
Security Indicator InspectionAIS004PL
*: CONSULT-II self-diagnostic results display screen “no malfunction is detected”. SYMPTOM
Displayed “SELF-DIAG
RESULTS” on CON- SULT-II screen. DIAGNOSTIC PROCE-
DURE SYSTEM (Malfunctioning part or mode)
Security indicator
lighting up*
Engine hard to start ECM INT CIRC-IMMU
[P1613] Refer to
BL-226, "
Diag-
nostic Procedure 1" . ECM
CHAIN OF ECM-IMMU [P1612] Refer to
BL-227, "
Diag-
nostic Procedure 2" . Open circuit in battery voltage line to BCM (NATS
IMMU) circuit
Open circuit in ignition line to BCM (NATS IMMU)
circuit
Open circuit in ground line to BCM (NATS IMMU)
circuit
Open or short circuit between BCM (NATS IMMU)
and ECM communication line.
ECM
BCM (NATS IMMU)
DIFFERENCE OF KEY [P1615] Refer to
BL-228, "
Diag-
nostic Procedure 3" . Unregistered key
NATS IMMU
CHAIN OF IMMU-KEY
[P1614] Refer to
BL-231, "
Diag-
nostic Procedure 6" . Open or short circuit between BCM (NATS IMMU)
and NATS antenna amp.
Malfunction of key ID chip
BCM (NATS IMMU)
Antenna amp.
ID DISCORD, IMM-ECM [P1611] Refer to
BL-229, "
Diag-
nostic Procedure 4"
System initialization has not yet been completed.
ECM
LOCK MODE [P1610] Refer to
BL-230, "
Diag-
nostic Procedure 5" . LOCK MODE
MIL staying ON
Security indicator
lighting up* DON'T ERASE
BEFORE CHECKING
ENG DIAG Refer to
BL-224, "WORK FLOW" . Engine trouble data and IVIS (NATS) trouble data
have been detected in ECM
SYMPTOM SYSTEM
(Malfunctioning part or mode) DIAGNOSTIC PROCEDURE
Security indicator does not operate* Security indicator
Refer to BL-233, "
Diagnostic
Procedure 7" .
Open circuit between Fuse and BCM (NATS
IMMU)
Continuation of initialization mode
BCM (NATS IMMU)