Revision: 2005 July 2005 FX
COMPONENT INSPECTION ...........................
.. 112
Intake Sensor Circuit ........................................... .. 113
COMPONENT DESCRIPTION ........................ .. 113
DIAGNOSIS PROCEDURE FOR INTAKE SEN-
SOR ................................................................. .. 113
COMPONENT INSPECTION ........................... .. 114
CONTROLLER ...................................................... ..115
Removal and Installation of A/C and AV Switch .. .. 115
REMOVAL ........................................................ .. 115
INSTALLATION ................................................ .. 115
AUTO AMP ............................................................ ..116
Removal and Installation of Unified Meter and A/C
Amp. .................................................................... .. 116
REMOVAL ........................................................ .. 116
INSTALLATION ................................................ .. 116
AMBIENT SENSOR ............................................... ..117
Removal and Installation ..................................... .. 117
REMOVAL ........................................................ .. 117
INSTALLATION ................................................ .. 117
IN-VEHICLE SENSOR ........................................... ..118
Removal and Installation ..................................... .. 118
REMOVAL ........................................................ .. 118
INSTALLATION ................................................ .. 118
SUNLOAD SENSOR ............................................. ..119
Removal and Installation ..................................... .. 119
REMOVAL ........................................................ .. 119
INSTALLATION ................................................ .. 119
INTAKE SENSOR .................................................. . 120
Removal and Installation ..................................... . 120
REMOVAL ........................................................ . 120
INSTALLATION ................................................ . 120
BLOWER UNIT ...................................................... . 121
Removal and Installation ..................................... . 121
REMOVAL ........................................................ . 121
INSTALLATION ................................................ . 121
Disassembly and Assembly ................................ . 122
BLOWER MOTOR ................................................. . 123
Removal and Installation ..................................... . 123
REMOVAL ........................................................ . 123
INSTALLATION ................................................ . 123
INTAKE DOOR MOTOR ........................................ . 124
Removal and Installation ..................................... . 124
REMOVAL ........................................................ . 124
INSTALLATION ................................................ . 124
IN-CABIN MICROFILTER ...................................... . 125
Removal and Installation ..................................... . 125
FUNCTION ....................................................... . 125
REPLACEMENT TIMING ................................. . 125
REPLACEMENT PROCEDURES .................... . 125
HEATER & COOLING UNIT ASSEMBLY ............. . 126
Removal and Installation ..................................... . 126
REMOVAL ........................................................ . 126
INSTALLATION ................................................ . 127
Disassembly and Assembly ................................ . 129
MODE DOOR MOTOR .......................................... . 131
Removal and Installation ..................................... . 131
REMOVAL ........................................................ . 131
INSTALLATION ................................................ . 131 AIR MIX DOOR MOTOR ........................................
.132
Removal and Installation ..................................... .132
REMOVAL ........................................................ .132
INSTALLATION ................................................ .132
HEATER CORE ...................................................... .133
Removal and Installation ..................................... .133
REMOVAL ........................................................ .133
INSTALLATION ................................................ .133
DUCTS AND GRILLES .......................................... .134
Removal and Installation ..................................... .134
REMOVAL ........................................................ .134
INSTALLATION ................................................ .137
REFRIGERANT LINES .......................................... .138
HFC-134a (R-134a) Service Procedure .............. .138
SETTING OF SERVICE TOOLS AND EQUIP-
MENT ............................................................... .138
Components ........................................................ .140
VQ35DE ........................................................... .140
VK45DE ............................................................ .141
Removal and Installation of Compressor ............. .141
REMOVAL ........................................................ .141
INSTALLATION ................................................ .143
Removal and Installation of Compressor Clutch . .144
REMOVAL ........................................................ .144
INSTALLATION ................................................ .146
Removal and Installation of Low-Pressure Flexible
Hose .................................................................... .148
REMOVAL ........................................................ .148
INSTALLATION ................................................ .149
Removal and Installation of High-Pressure Flexible
Hose .................................................................... .149
REMOVAL ........................................................ .149
INSTALLATION ................................................ .150
Removal and Installation of Low-Pressure Pipe 1
(Engine Compartment) ........................................ .150
REMOVAL ........................................................ .150
INSTALLATION ................................................ .151
Removal and Installation of High-Pressure Pipe 1
and 2 (Engine Compartment) .............................. .151
REMOVAL ........................................................ .151
INSTALLATION ................................................ .152
Removal and Installation of Low-Pressure Pipe 2
and High-Pressure Pipe 3 ................................... .152
REMOVAL ........................................................ .152
INSTALLATION ................................................ .153
Removal and Installation of Liquid Tank .............. .154
REMOVAL ........................................................ .154
INSTALLATION ................................................ .154
Removal and Installation of Condenser ............... .155
REMOVAL ........................................................ .155
INSTALLATION ................................................ .155
Removal and Installation of Refrigerant Pressure
Sensor ................................................................. .156
REMOVAL ........................................................ .156
INSTALLATION ................................................ .156
Removal and Installation of Evaporator ............... .156
REMOVAL ........................................................ .156
INSTALLATION ................................................ .156
Removal and Installation of Expansion Valve ...... .157
ATC-4Revision: 2005 July 2005 FX
REMOVAL ........................................................
.157
INSTALLATION ................................................. .157
Checking for Refrigerant Leaks ........................... .158
Checking System for Leaks Using the Fluorescent
Leak Detector ...................................................... .158
Dye Injection ........................................................ .158
Electronic Refrigerant Leak Detector ................... .159
PRECAUTIONS FOR HANDLING LEAK DETECTOR ......................................................
.159
CHECKING PROCEDURE ............................... .160
SERVICE DATA AND SPECIFICATIONS (SDS) ... .162
Compressor ......................................................... .162
Lubricant .............................................................. .162
Refrigerant ........................................................... .162
Engine Idling Speed ............................................. .162
Belt Tension ......................................................... .162
PRECAUTIONS ATC-13
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
After connecting line, perform leak test and make sure that there is no leakage from connections.
When the refrigerant leaking point is found, disconnect that line and replace the O-ring. Then
tighten connections of seal seat to the specified torque.
Precautions for Servicing CompressorAJS001XM
Plug all openings to prevent moisture and foreign matter from entering.
When the compressor is removed, store it in the same way as it is when mounted on the car.
When replacing or repairing compressor, follow “Maintenance of Lubricant Quantity in Compres-
sor” exactly. Refer to AT C - 2 7 , "
Maintenance of Lubricant Quantity in Compressor" .
Keep friction surfaces between clutch and pulley clean. If the surface is contaminated with lubri-
cant, wipe it off by using a clean waste cloth moistened with thinner.
After compressor service operation, turn the compressor shaft by hand more than five turns in
both directions. This will equally distribute lubricant inside the compressor. After the compressor
is installed, let the engine idle and operate the compressor for one hour.
After replacing the compressor magnet clutch, apply voltage to the new one and check for normal
operation.
Precautions for Service EquipmentAJS001XN
RECOVERY/RECYCLING EQUIPMENT
Be certain to follow the manufacturer’s instructions for machine operation and machine maintenance. Never
introduce any refrigerant other than that specified into the machine.
ELECTRONIC LEAK DETECTOR
Be certain to follow the manufacturer’s instructions for tester operation and tester maintenance.
RHA861F
ATC-16
PRECAUTIONS
Revision: 2005 July 2005 FX
Precautions for Leak Detection DyeAJS001XO
The A/C system contains a fluorescent leak detection dye used for locating refrigerant leaks. An ultraviolet
(UV) lamp is required to illuminate the dye when inspecting for leaks.
Always wear fluorescence enhancing UV safety goggles to protect your eyes and enhance the visibility of
the fluorescent dye.
The fluorescent dye leak detector is not a replacement for an electronic refrigerant leak detector. The fluo-
rescent dye leak detector should be used in conjunction with an electronic refrigerant leak detector (SST:
J-41995) to pin-point refrigerant leaks.
For your safety and your customer’s satisfaction, read and follow all manufacture ′s operating instructions
and precautions prior to performing the work.
A compressor shaft seal should not be repaired because of dye seepage. The compressor shaft seal
should only be repaired after confirming the leak with an electronic refrigerant leak detector (SST: J-
41995).
Always remove any remaining dye from the leak area after repairs are completed to avoid a misdiagnosis
during a future service.
Never allow dye to come into contact with painted body panels or interior components. If dye is spilled,
clean immediately with the approved dye cleaner. Fluorescent dye left on a surface for an extended period
of time cannot be removed.
Never spray the fluorescent dye cleaning agent on hot surfaces (engine exhaust manifold, etc.).
Never use more than one refrigerant dye bottle (1/4 ounce /7.4 cc) per A/C system.
Leak detection dyes for HFC-134a (R-134a) and CFC-12 (R-12) A/C systems are different. Never use
HFC-134a (R-134a) leak detection dye in CFC-12 (R-12) A/C system or CFC-12 (R-12) leak detection
dye in HFC-134a (R-134a) A/C system, or A/C system damage may result.
The fluorescent properties of the dye will remain for three years or little over unless a compressor mal-
function occurs.
IDENTIFICATION
NOTE:
Vehicles with factory installed fluorescent dye have a green label.
Vehicles without factory installed fluorescent dye have a blue label.
IDENTIFICATION LABEL FOR VEHICLE
Vehicles with factory installed fluorescent dye have this identification
label on the front side of hood.
SHA436FA
ATC-22
REFRIGERATION SYSTEM
Revision: 2005 July 2005 FX
V-6 Variable Displacement CompressorAJS001BE
GENERAL INFORMATION
1. The V-6 variable compressor differs from previous units. The vent temperatures of the V-6 variable com-
pressor do not drop too far below 5 °C (41 °F) when:
Evaporator intake air temperature is less than 20 °C (68 °F).
Engine is running at speeds less than 1,500 rpm.
This is because the V-6 compressor provides a means of “capacity” control.
2. The V-6 variable compressor provides refrigerant control under varying conditions. During cold winters, it may not produce high refrigerant pressure discharge (compared to previous units) when used with air
conditioning systems.
3. A “clanking” sound may occasionally be heard during refrigerant charge. The sound indicates that the tilt angle of the wobble (swash) plate has changed and is not a malfunction.
4. For air conditioning systems with the V-6 compressor, the clutch remains engaged unless: the system main switch, fan switch or ignition switch is turned OFF. When ambient (outside) temperatures are low or
when the amount of refrigerant is insufficient, the clutch is disengaged to protect the compressor.
LUBRICANT ATC-27
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
LUBRICANTPFP:KLG00
Maintenance of Lubricant Quantity in CompressorAJS00149
The lubricant in the compressor circulates through the system with the refrigerant. Add lubricant to compres-
sor when replacing any component or after a large refrigerant leakage occurred. It is important to maintain the
specified amount.
If lubricant quantity is not maintained properly, the following malfunctions may result:
Lack of lubricant: May lead to a seized compressor.
Excessive lubricant: Inadequate cooling (thermal exchange interference)
LUBRICANT
LUBRICANT RETURN OPERATION
Adjust the lubricant quantity according to the test group shown below.
1. CHECK LUBRICANT RETURN OPERATION
Can lubricant return operation be performed?
A/C system works properly.
There is no evidence of a large amount of lubricant leakage.
CAUTION:
If excessive lubricant leakage is noted, never perform the lubricant return operation.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. PERFORM LUBRICANT RETURN OPERATION, PROCEEDING AS FOLLOWS
1. Start engine, and set the following conditions:
–Engine speed: Idling to 1,200 rpm
–A/C switch: ON
–Blower speed: Max. position
–Temp. control: Optional [Set so that intake air temperature is 25 to 30 °C (77 to 86 °F).]
–Intake position: Recirculation (REC)
2. Perform lubricant return operation for about 10 minutes.
3. Stop engine.
>> GO TO 3.
3. CHECK REPLACEMENT PART
Should the compressor be replaced?
YES >> GO TO AT C - 2 9 , "LUBRICANT ADJUSTING PROCEDURE FOR COMPRESSOR REPLACE-
MENT" .
NO >> GO TO AT C - 2 8 , "
LUBRICANT ADJUSTING PROCEDURE FOR COMPONENTS REPLACE-
MENT EXCEPT COMPRESSOR" .
Name : NISSAN A/C System Oil Type S
Part number : KLH00-PAGS0
ATC-32
AIR CONDITIONER CONTROL
Revision: 2005 July 2005 FX
Stop Signal:
At the end of each transmission, a stop operation, in-operation, or internal malfunction message is delivered to
the unified meter and A/C amp. This completes one data transmission and control cycle.
AIR MIX DOOR CONTROL (AUTOMATIC TEMPERATURE CONTROL)
The air mix door is automatically controlled so that in-vehicle temperature is maintained at a predetermined
value by the temperature setting, ambient temperature, in-vehicle temperature and amount of sunload.
FAN SPEED CONTROL
Blower speed is automatically controlled by the temperature setting, ambient temperature, in-vehicle tempera-
ture, intake temperature, amount of sunload and air mix door position.
With pressing AUTO switch, the blower motor starts to gradually increase air flow volume.
When engine coolant temperature is low, the blower motor operation is delayed to prevent cool air from flow-
ing.
INTAKE DOOR CONTROL
The intake doors are automatically controlled by the temperature setting, ambient temperature, in-vehicle tem-
perature, intake temperature, amount of sunload and ON-OFF operation of the compressor.
OUTLET DOOR CONTROL
The outlet door is automatically controlled by the temperature setting, ambient temperature, in-vehicle temper-
ature, intake temperature and amount of sunload.
RJIA1749E
TROUBLE DIAGNOSIS ATC-43
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
Component Parts and Harness Connector LocationAJS0014L
ENGINE COMPARTMENT
RJIA1963E