GW-16
POWER WINDOW SYSTEM
Revision: 2005 July 2005 FX
System DescriptionAIS004PX
WITH FRONT POWER WINDOW ANTI-PINCH SYSTEM
Power is supplied at all time
through 50A fusible link (letter M , located in the fuse and fusible link box)
to BCM terminal 55, and
through BCM terminal 54
to power window main switch terminal 19
to front power window switch (passenger side) terminal 10.
through 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 42.
With ignition switch in ON or START position,
Power is supplied
through 15A fuse [No. 1 , located in the fuse block (J/B)]
to BCM terminal 38, and
trough BCM terminal 53
to power window main switch terminal 10
to rear power window switch (LH and RH) terminal 1.
Ground supplied
to BCM terminal 49 and 52
through body grounds M35, M45 and M85.
to power window main switch terminal 17
through body grounds M35, M45 and M85.
to front power window switch (passenger side) terminal 11
through body grounds M35, M45 and M85.
WITH FRONT AND REAR WINDOW ANTI-PINCH SYSTEM
Power is supplied at all time
through 50A fusible link (letter M , located in the fuse and fusible link box)
to BCM terminal 55, and
through BCM terminal 54
to power window main switch terminal 19
to front power window switch (passenger side) terminal 10
to rear power window switch (LH and RH) terminal 10.
through 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 42.
With ignition switch in ON or START position,
Power is supplied
through 15A fuse [No. 1, located in the fuse block (J/B)]
to BCM terminal 38, and
through BCM terminal 53
to power window main switch terminal 10
Ground supplied
to BCM terminal 49 and 52
through body grounds M35, M45 and M85.
to power window main switch terminal 17
through body grounds M35, M45 and M85.
to front power window switch (passenger side) terminal 11
through body grounds M35, M45 and M85.
to rear power window switch (LH and RH) terminal 11
through body grounds B15 and B45.
POWER WINDOW SYSTEM GW-21
C
D E
F
G H
J
K L
M A
B
GW
Revision: 2005 July 2005 FX
RETAINED POWER OPERATION
When the ignition switch is turned to the OFF position from ON or START position.
Power is supplied for 45 seconds / with front power window anti-pinch system
through BCM terminal 53
to power window main switch terminal 10
to rear power window switch (LH and RH) terminals 1.
Power is supplied for 45 seconds / with front and rear power window anti-pinch system
through BCM terminal 53
to power window main switch terminal 10.
When power and ground are supplied, the BCM continues to be energized, and the power window can be
operated.
The retained power operation is canceled when the driver or passenger side door is opened.
RAP signal period can be changed by CONSULT-II. Refer to GW-40, "
CONSULT-II Function (BCM)" .
ANTI-PINCH SYSTEM
With front power window anti-pinch system
Power window main switch and front power window switch (passenger side) monitors the power window motor
operation and the power window position (full closed or other) for driver side and passenger side power win-
dow by the signals from encoder and limit switch in front power window motor (driver side and passenger
side).
When power window main switch detects interruption during the following close operation,
automatic close operation when ignition switch is in the “ON” position
automatic close operation during retained power operation
manual close operation during retained power operation
power window main switch or front power window switch (passenger side) controls each power window motor
for open and the power window will be lowered about 150 mm (5.91 in).
With front and rear power window anti-pinch system
Power window main switch and each power window switch monitors the power window motor operation and
the power window position (full closed or other) for each power window by the signals from encoder and limit
switch in power window motor.
When power window switch detects interruption during the following close operation,
automatic close operation when ignition switch is in the “ON” position
automatic close operation during retained power operation
manual close operation during retained power operation
Power window main switch or each power window switch controls each power window motor for open and the
power window will be lowered about 150 mm (5.91 in).
POWER WINDOW CONTROL BY THE KEY CYLINDER SWITCH
When ignition key switch is OFF, front power window can be opened or closed by turning the key cylinder
switch UNLOCK / LOCK position more than 1.5 second over condition.
Power window can be opened as the door key cylinder is kept fully turning to the UNLOCK position.
Power window can be closed as the door key cylinder is kept fully turning to the LOCK position.
The power window DOWN stops when the following operations are carried out.
While performing open / close the window, power window is stopped at the position as the door key cylin-
der is placed on NEUTRAL.
When the ignition switch is turned ON while the power window DOWN is operated.
GW-28
POWER WINDOW SYSTEM
Revision: 2005 July 2005 FX
Terminal and Reference Value for BCM / With Front Power Window Anti-Pinch
System
AIS004Q2
Terminal Wire color Item Condition Voltage [V]
(Approx.)
12 P/B Front door switch
passenger side signal ON (Open) 0
OFF (Close) Battery voltage
22 OR Power window serial link IGN SW ON or power window
timer operating.
38 W/L Ignition switch (ON or START) Ignition switch
(ON or START position) Battery voltage
39 L CAN - H — —
40 R CAN - L — —
42 L/R Power source (Fuse) — Battery voltage
49 B Ground (signal) — 0
52 B Ground (power) — 0
53 Y/B Rap signal IGN SW ON Battery voltage
Within 45 second after ignition
switch is turned to OFF Battery voltage
When driver side or passenger
side door is open in power win-
dow timer is operates 0
54 W Power window power supply — Battery voltage
55 G Power source (Fusible link) — Battery voltage
62 W Front door switch
driver side signal ON (Open) 0
OFF (Close) Battery voltage
PIIA2344J
POWER WINDOW SYSTEM GW-29
C
D E
F
G H
J
K L
M A
B
GW
Revision: 2005 July 2005 FX
Terminal and Reference Value for Power Window Main Switch / With Front
Power Window Anti-pinch System
AIS004Q3
Terminal Wire color Item Condition Voltage [V]
(Approx.)
1Y Rear LH power window
UP signal When rear LH switch in
power window main switch is
UP at operated. Battery voltage
2 SB Limit switch and encoder ground — 0
3R Rear LH power window
DOWN signal When rear LH switch in
power window main switch is
DOWN at operated. Battery voltage
4P Door key cylinder switch
LOCK signal Key position
(Neutral → Locked) 5
→ 0
5G Rear RH power window
DOWN signal When rear RH switch in
power window main switch is
DOWN at operated. Battery voltage
6OR Door key cylinder switch
UNLOCK signal Key position
(Neutral → Unlocked) 5
→ 0
7LG Rear RH power window
UP signal When rear RH switch in
power window main switch is
UP at operated. Battery voltage
8L Front driver side
power window motor UP signal When front LH switch in
power window main switch is
UP at operated Battery voltage
9 GY Limit switch signal Driver side door window is
between fully-open and just
before fully-closed position (ON) 0
Driver side door window is
between just before fully-closed
position and fully-closed position
(OFF) 5
10 BR Rap signal IGN SW ON Battery voltage
Within 45 second after ignition
switch is turned to OFF Battery voltage
When driver side or passenger
side door open in power window
timer is operates 0
11 B Front driver side
power window motor DOWN signal When front LH switch in
power window main switch is
DOWN at operated Battery voltage
13 PU Encoder pulse signal When power window motor oper-
ates.
14 Y Power window serial link IGN SW ON or power window
timer operating.
15 W Encoder power supply When ignition switch ON or
power window timer operates 10
OCC3383D
PIIA2344J
GW-30
POWER WINDOW SYSTEM
Revision: 2005 July 2005 FX
Terminal and Reference Value for Front Power Window Switch (Passenger Side)
/ With Front Power Window Anti-pinch System
AIS004Q4
17 B Ground — 0
19 W Battery power supply — Battery voltage
Terminal Wire color Item Condition
Voltage [V]
(Approx.)
Terminal Wire color Item Condition Voltage [V]
(Approx.)
3 SB Limit switch and encoder ground — 0
4 R Encoder power supply When ignition switch ON or
power window timer operates 10
8L Front passenger side
power window motor UP signal When power window motor is
UP at operated. Battery voltage
9G Front passenger side
power window motor DOWN signal When power window motor is
DOWN at operated. Battery voltage
10 W Battery power supply — Battery voltage 11 B Ground — 0
12 PU Encoder pulse signal When power window motor oper-
ates.
15 GY Limit switch signal Passenger side door window is
between fully-open and just
before fully-closed position (ON) 0
Passenger side door window is
between just before fully-closed
position and fully-closed position
(OFF) 5
16 Y Power window serial link IGN SW ON or power window
timer operating.
OCC3383D
PIIA2344J
POWER WINDOW SYSTEM GW-37
C
D E
F
G H
J
K L
M A
B
GW
Revision: 2005 July 2005 FX
Terminal and Reference Value for BCM / With Front and Rear Power Window
Anti-Pinch
AIS004Q7
Terminal Wire color Item Condition Voltage [V]
(Approx.)
12 P/B Front door switch
passenger side signal ON (Open) 0
OFF (Close) Battery voltage
22 OR Power window serial link IGN SW ON or power window
timer operating.
38 W/L Ignition switch (ON or START) Ignition switch
(ON or START position) Battery voltage
39 L CAN - H — 0
40 R CAN - L — 0
42 L/R Power source (Fuse) — Battery voltage
49 B Ground (signal) — 0
52 B Ground (power) — 0
53 Y/B Rap signal IGN SW ON Battery voltage
Within 45 second after ignition
switch is turned to OFF Battery voltage
When driver side or passenger
side door is open in power win-
dow timer is operates 0
54 W Power window power supply — Battery voltage
55 G Power source (Fusible link) — Battery voltage
62 W Front door switch
driver side signal ON (Open) 0
OFF (Close) Battery voltage
PIIA2344J
GW-38
POWER WINDOW SYSTEM
Revision: 2005 July 2005 FX
Terminal and Reference Value for Power Window Main Switch / With Front and
Rear Power Window Anti-pinch System
AIS004Q8
Terminal Wire color Item Condition Voltage [V]
(Approx.)
2 SB Limit switch and encoder ground — 0
4P Door key cylinder switch
LOCK signal Key position
(Neutral → Locked) 5
→ 0
6OR Door key cylinder switch
UNLOCK signal Key position
(Neutral → Unlocked) 5
→ 0
8L Front driver side power window
motor UP signal When front LH switch in
power window main switch is
UP at operated. Battery voltage
9 GY Limit switch signal Driver side door window is between
fully-open and just before fully-
closed position (ON). 0
Driver side door window is between
just before fully-closed position and
fully-closed position (OFF). 5
10 BR Rap signal IGN SW ON Battery voltage
Within 45 second after ignition
switch is turned to OFF Battery voltage
When driver side or passenger side
door is open in power window timer
is operates 0
11 B Front driver side power window
motor DOWN signal When front LH switch in
power window main switch is
DOWN at operated. Battery voltage
13 PU Encoder pulse signal When power window motor oper-
ates.
14 Y Power window serial link IGN SW ON or power window timer
operating.
15 W Encoder power supply When ignition switch ON or power
window timer operates. 10
17 B Ground — 0
19 W Battery power supply — Battery voltage
OCC3383D
PIIA2344J
POWER WINDOW SYSTEM GW-39
C
D E
F
G H
J
K L
M A
B
GW
Revision: 2005 July 2005 FX
Terminal and Reference Value for (Front and Rear) Power Window Switch / With
Front and Rear Window Anti-pinch System
AIS004Q9
( ): Rear power window switch (LH or RH)
Terminal Wire color Item Condition Voltage [V]
(Approx.)
3 SB
(OR) Limit switch and encoder ground — 0
4 R
(PU) Encoder power supply
When ignition switch ON or power
window timer operates 10
8L Power window motor
UP signal When power window motor is
UP at operated. Battery voltage
9G Power window motor
DOWN signal When power window motor is
DOWN at operated. Battery voltage
10 W Battery power supply — Battery voltage 11 B G r o u n d — 0
12 PU
(GY) Encoder pulse signal
When power window motor oper-
ates.
15 GY
(R) Limit switch signal Door window is between fully-open
and just before fully-closed position
(ON) 0
Door window is between just before
fully-closed position and fully-closed
position (OFF) 5
16 Y Power window serial link IGN SW ON or power window timer
operating.
OCC3383D
PIIA2344J