AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER
The trimmer compensates for differences in range of 3ÉC between temperature setting (Temperature control
dial position) and temperature felt by driver.
Operating procedures for this trimmer are as follows:
1. Set temperature at 25ÉC.
2. Set fan control dial to OFF.
3. Turn ignition switch ON.
4. Set in self-diagnostic mode as follows. Within 10 seconds after starting engine (ignition switch is turned
ON.), press intake switch for at least 5 seconds.
5. Turn temperature control dial as desired. Temperature will change at a rate of 1ÉC each time a dial is
turned.
Setting temperatureLED status of each switch
FRE REC A/C
þ3ÉC ON ON ON
þ2ÉC ON ON OFF
þ1ÉC ON OFF ON
0ÉC (Initial setting) OFF OFF OFF
1ÉC OFF OFF ON
2ÉC OFF ON OFF
3ÉC OFF ON ON
When battery cable is disconnected, trimmer operation is canceled. Temperature set becomes that of initial
condition, i.e. 0ÉC.
AUXILIARY MECHANISM: FOOT POSITION SETTING TRIMMER
CAUTION:
This A/C system cannot perform the setup of the FOOT position.
LED of A/C switch illuminates. It means that it is ®xed to the initial setting.
AUXILIARY MECHANISM: INLET PORT MEMORY FUNCTION
When ignition switch is turned from OFF to ON, inlet port can be set to AUTO or manual.
Operating procedures for this trimmer are as follows:
1. Set fan control dial to 1st - 25th step.
2. Turn ignition switch ON.
3. Set in self-diagnostic mode as follows. Within 10 seconds after starting engine (ignition switch is turned
ON.), press intake switch for at least 5 seconds.
4. Press intake switch as desired.
LED status of intake switch Setting status
Setting changeover
method
FRE REC FRE REC
OFF ONAUTO control (Initial set-
ting)Manual REC status is
memorized.
(Initial setting)
Intake switch: ON ON OFFManual FRE status is
memorized.AUTO control
ON ONManual FRE status is
memorized.Manual REC status is
memorized.
OFF OFF AUTO control AUTO control
TROUBLE DIAGNOSESAUTO
Self-diagnosis (Cont'd)
HA-4031