Page 1693 of 3371
EC-502Revision: August 2007
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
2004 QX56
10. CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached.
2. Check if water will drain from the EVAP canister.
Ye s o r N o
Yes >> GO TO 11.
No >> GO TO 13.
11 . CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.2 kg (4.9 lb).
OK or NG
OK >> GO TO 13.
NG >> GO TO 12.
12. DETECT MALFUNCTIONING PART
Check the following.
EVAP canister for damage
EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
13. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
BBIA0351E
Page 1694 of 3371
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-503
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
Component InspectionUBS00HAZ
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
Without CONSULT-II
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
Removal and InstallationUBS00HB0
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EM-15, "INTAKE MANIFOLD" .
Condition
(PURG VOL CONT/V value)Air passage continuity
between A and B
100% Yes
0% No
PBIB2058E
ConditionAir passage continuity
between A and B
12V direct current supply between
terminals 1 and 2Ye s
No supply No
PBIB2059E
Page 1698 of 3371

DTC P1446 EVAP CANISTER VENT CONTROL VALVE
EC-507
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureUBS00HB6
1. CHECK RUBBER TUBE
1. Turn ignition switch OFF.
2. Disconnect rubber tube connected to EVAP canister vent control valve.
3. Check the rubber tube for clogging.
OK or NG
OK >> GO TO 2.
NG >> Clean rubber tube using an air blower.
2. CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-508, "
Component Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Replace EVAP canister vent control valve.
3. CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached.
2. Check if water will drain from the EVAP canister.
Ye s o r N o
Yes >> GO TO 4.
No >> GO TO 6.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
11 7 L / YEVAP canister vent control
valve[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
BBIA0443E
BBIA0351E
Page 1699 of 3371

EC-508Revision: August 2007
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
2004 QX56
4. CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.2 kg (4.9 lb).
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. DETECT MALFUNCTIONING PART
Check the following.
EVAP canister for damage
EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
6. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check connectors for water.
OK or NG
OK >> GO TO 7.
NG >> Replace EVAP control system pressure sensor.
7. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC-301, "
Component Inspection" .
OK or NG
OK >> GO TO 8.
NG >> Replace EVAP control system pressure sensor.
8. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionUBS00HB7
EVAP CANISTER VENT CONTROL VALVE
With CONSULT-II
1. Remove EVAP canister vent control valve from EVAP canister.
2. Check portion B of EVAP canister vent control valve for being
rusted.
If NG, replace EVAP canister vent control valve.
If OK, go to next step.
3. Reconnect harness connectors disconnected.
4. Turn ignition switch ON.Water should not exist.
PBIB1033E
Page 1700 of 3371

DTC P1446 EVAP CANISTER VENT CONTROL VALVE
EC-509
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
5. Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.
6. Check air passage continuity and operation delay time.
Make sure that new O-ring is installed properly.
Operation takes less than 1 second.
If NG, replace EVAP canister vent control valve.
If OK, go to next step.
7. Clean the air passage (Portion A to B ) of EVAP canister vent control valve using an air blower.
8. Perform step 6 again.
Without CONSULT-II
1. Remove EVAP canister vent control valve from EVAP canister.
2. Check portion B of EVAP canister vent control valve for being
rusted.
3. Check air passage continuity and operation delay time under the
following conditions.
Make sure that new O-ring is installed properly.
Operation takes less than 1 second.
If NG, replace EVAP canister vent control valve.
If OK, go to next step.
4. Clean the air passage (Portion A to B ) of EVAP canister vent control valve using an air blower.
5. Perform step 3 again.
Condition VENT CONTROL/V Air passage continuity between A and B
ON No
OFF Yes
PBIB1679E
PBIB1033E
Condition Air passage continuity between A and B
12V direct current supply between
terminals 1 and 2No
OFF Yes
PBIB1034E
Page 1706 of 3371

DTC P1564 ICC STEERING SWITCH
EC-515
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
2. CHECK ICC STEERING SWITCH GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect combination switch harness connector.
3. Disconnect ECM harness connector.
4. Check harness continuity between combination switch terminal
15 and ECM terminal 67.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M31, E152
Harness connectors E19, F33
Combination switch (spiral cable)
Harness for open and short between ECM and combination switch
>> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK ICC STEERING SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 99 and combination switch terminal 14.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M31, E152
Combination switch (spiral cable)
Harness for open and short between ECM and combination switch
>> Repair open circuit or short to ground or short to power in harness or connectors.
6. CHECK ICC STEERING SWITCH
Refer to EC-516, "
Component Inspection" .
OK or NG
OK >> GO TO 7.
NG >> Replace ICC steering switch.Continuity should exist.
BBIA0469E
Continuity should exist.
Page 1713 of 3371

EC-522Revision: August 2007
DTC P1564 ASCD STEERING SWITCH
2004 QX56
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M31, E152
Harness connectors E19, F33
Combination switch (spiral cable)
Harness for open and short between ECM and combination switch
>> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK ASCD STEERING SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 99 and combination switch terminal 14.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M31, E152
Combination switch (spiral cable)
Harness for open and short between ECM and combination switch
>> Repair open circuit or short to ground or short to power in harness or connectors.
6. CHECK ASCD STEERING SWITCH
Refer to EC-522, "
Component Inspection" .
OK or NG
OK >> GO TO 7.
NG >> Replace ASCD steering switch.
7. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionUBS00HBE
ASCD STEERING SWITCH
1. Disconnect combination switch (spiral cable).
2. Check continuity between ASCD steering switch terminals 14
and 15 with pushing each switch.Continuity should exist.
Switch Condition Resistance [Ω]
ON/OFF(MAIN) switchPressed Approx. 0
Released Approx. 4,000
COAST/SET switchPressed Approx. 660
Released Approx. 4,000
PBIB1673E
Page 1720 of 3371
DTC P1572 ICC BRAKE SWITCH
EC-529
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
2. CHECK OVERALL FUNCTION-II
With CONSULT-II
Check “BRAKE SW2” indication in “DATA MONITOR” mode.
Without CONSULT-II
Check voltage between ECM terminal 101 and ground under the fol-
lowing conditions.
OK or NG
OK >> GO TO 15.
NG >> GO TO 10.
3. CHECK DTC WITH ICC UNIT
Refer to ACS-26, "
TROUBLE DIAGNOSIS — GENERAL DESCRIPTION" .
OK or NG
OK >> GO TO 4.
NG >> Repair or replace.
CONDITION INDICATION
When brake pedal is fully released OFF
When brake pedal is slightly depressed ON
SEC0 13 D
CONDITION VOLTAGE
When brake pedal is fully released Approximately 0V
When brake pedal is slightly depressed Battery voltage
MBIB0060E