LT-82
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: August 20072004 QX56
REMOTE KEYLESS ENTRY SYSTEM OPERATION
Power is supplied at all times
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70, and
through 10A fuse [No. 19, located in the fuse block (J/B)]
to combination meter terminal 8.
Ground is supplied
to BCM terminal 67 and
to combination meter terminal 17
through grounds M57, M61 and M79.
When the remote keyless entry system is triggered by input from the keyfob, the BCM, interpreting it as turn
signal is ON, output turn signal from BCM terminals 60 and 61.
The BCM supplies power
through BCM terminals 60 and 61
to front turn/fog lamp LH and RH terminal 2
through front turn/fog lamp LH and RH terminal 3
to grounds E9, E15 and E24, and
to rear turn signal lamp LH terminal 1
through rear turn signal lamp LH terminal 3
to grounds B7 and B19, and
to rear turn signal lamp RH terminal 1
through rear turn signal lamp RH terminal 3
to grounds B117 and B132.
BCM sends signal to combination meter through CAN communication lines, and turns on turn signal indicator
lamps within combination meter.
With power and input supplied, the BCM controls the flashing of the hazard warning lamps when keyfob is
used to activate the remote keyless entry system.
COMBINATION SWITCH READING FUNCTION
Refer to BCS-3, "COMBINATION SWITCH READING FUNCTION" .
CAN Communication System DescriptionEKS007BK
Refer to LAN-5, "CAN COMMUNICATION" .
LT-130
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
System DescriptionEKS007CY
When room lamp and personal lamp switch is in DOOR position, room lamp and personal lamp ON/OFF is
controlled by timer according to signals from switches including key switch and key lock solenoid, front door
switch LH, unlock signal from keyfob, door lock and unlock switch, front door lock assembly LH (key cylinder
switch), ignition switch, and glass hatch ajar switch.
When room lamp and personal lamp turns ON, there is a gradual brightening over 1 second. When room lamp
and personal lamp turns OFF, there is a gradual dimming over 1 second.
The room lamp and personal lamp timer is controlled by the BCM (body control module).
Room lamp and personal lamp timer control settings can be changed with CONSULT-II.
Ignition keyhole illumination turns ON when front door LH is opened (door switch ON) or key is removed from
key cylinder. Illumination turns OFF when front door LH is closed (door switch OFF).
Step and foot lamp turns ON when front or rear doors are opened (door switch ON). Lamp turns OFF when
front and rear doors are closed (all door switches OFF).
POWER SUPPLY AND GROUND
Power is supplied at all times
through 10A fuse [No. 19, located in the fuse block (J/B)]
to key switch and key lock solenoid terminal 3, and
through 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 57, and
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70.
When the key is inserted in key switch and key lock solenoid, power is supplied
through the key switch and key lock solenoid terminal 4
to BCM terminal 37.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38.
Ground is supplied
to BCM terminal 67
through grounds M57, M61 and M79.
When the front door LH is opened, ground is supplied
to BCM terminal 47
through case ground of front door switch LH.
When the front door RH is opened, ground is supplied
to BCM terminal 12
through case ground of front door switch RH.
When the rear door LH is opened, ground is supplied
to BCM terminal 48
through case ground of rear door switch LH.
When the rear door RH is opened, ground is supplied
to BCM terminal 13
through case ground of rear door switch RH.
When the liftgate is opened, ground is supplied
to BCM terminal 43
through back door latch (door ajar switch) terminal 7
through back door latch (door ajar switch) terminal 8
through grounds B7 and B19.
When the glass hatch is opened, ground is supplied
to BCM terminal 42
through case ground of glass hatch ajar switch.
INTERIOR ROOM LAMP
LT-131
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
When the front door LH or RH is unlocked by the door lock and unlock switch, BCM receives serial data
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14 or power window and door lock/
unlock switch RH terminal 16
through main power window and door lock/unlock switch terminal 17 or power window and door lock/
unlock switch RH terminal 11
through grounds M57, M61 and M79.
When the front door LH is unlocked by the key, the BCM receives serial data
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14
through main power window and door lock/unlock switch terminal 6
through front door lock assembly LH (key cylinder switch) terminal 6
through front door lock assembly LH (key cylinder switch) terminal 5
through grounds M57, M61 and M79.
When a signal, or combination of signals is received by BCM, ground is supplied
to door mirror LH and RH terminal 13
to front room/map lamp assembly terminal 1
through front room/map lamp assembly terminal 2
to personal lamps terminal 1
through BCM terminal 63, and
to cargo lamp terminal 1
through BCM terminal 49.
With power and ground supplied, the lamps illuminate.
SWITCH OPERATION
When any door switch is ON (door is opened), ground is supplied
to front and rear step lamps LH and RH and foot lamp LH and RH terminal –
through BCM terminal 62.
And power is supplied
through BCM terminal 56
to front and rear step lamps LH and RH terminal +
to ignition keyhole illumination terminal +
to door mirror LH and RH terminal 12
to front room/map lamp assembly terminal 6
to vanity lamps terminal 1
to personal lamps terminal 3
to cargo lamp terminal 2, and
to foot lamp LH and RH terminal +.
When map lamp switch is ON, ground is supplied
to front room/map lamp assembly terminal 5
through grounds M57, M61 and M79.
When vanity lamp (LH and RH) is ON, ground is supplied
to vanity lamp (LH and RH) terminal 2
through grounds M57, M61 and M79.
When cargo lamp is ON, ground is supplied through cargo lamp case ground.
ROOM LAMP TIMER OPERATION
When lamp switch is in DOOR position, and when all conditions below are met, BCM performs timer control
(maximum 30 seconds) for interior room lamp and map lamp ON/OFF.
Power is supplied
through 10A fuse [No. 19, located in the fuse block (J/B)]
LT-132
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
to key switch and key lock solenoid terminal 3.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
Serial data is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
At the time that front door LH is opened, BCM detects that front door LH is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns the interior room lamps ON for 30 sec-
onds.
Key is in ignition key cylinder (key switch ON), power is supplied
through key switch and key lock solenoid terminal 4
to BCM terminal 37.
When key is removed from key switch and key lock solenoid (key switch OFF), power supply to BCM terminal
37 is terminated. BCM detects that key has been removed, determines that interior room lamp and map lamp
timer conditions are met, and turns the interior room lamps ON for 30 seconds.
When front door LH opens → closes, and the key is not inserted in the key switch and key lock solenoid (key
switch OFF), BCM terminal 47 changes between 0V (door open) → 12V (door closed). The BCM determines
that conditions for interior room lamp operation are met and turns the interior room lamp ON for 30 seconds.
Timer control is canceled under the following conditions.
Front door LH is locked [when locked by keyfob, main power window and door lock/unlock switch, or front
door lock assembly LH (key cylinder switch)]
Front door LH is opened (front door switch LH turns ON)
Ignition switch ON.
INTERIOR LAMP BATTERY SAVER CONTROL
If interior lamp is left “ON”, it will not be turned off even when door is closed.
BCM turns off interior lamp automatically to save battery 30 minutes after ignition switch is turned off.
BCM controls interior lamps listed below:
Vanity lamp
Room/map lamp
Cargo lamp
Personal lamp
Step lamps
Puddle lamps
Foot lamps
Ignition keyhole illumination
After lamps turn OFF by the battery saver system, the lamps illuminate again when
signal received from keyfob, or main power window and door lock/unlock switch or front door lock assem-
bly LH (key cylinder switch) is locked or unlocked
door is opened or closed
key is removed from ignition key cylinder (key switch OFF) or inserted in ignition key cylinder (key switch
ON).
Interior lamp battery saver control period can be changed by the function setting of CONSULT-II.
LT-142
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
Terminals and Reference Values for BCMEKS007D1
How to Proceed With Trouble DiagnosisEKS007D2
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT-130, "
System Description" .
3. Carry out the Preliminary Check. Refer to LT- 1 4 3 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Does the interior room lamp operate normally? If YES: GO TO 6. If NO: GO TO 4.
6. Inspection End.
Te r m i n a l
No.Wire
colorSignal nameMeasuring condition
Reference value
(Approx.) Ignition
switchOperation or condition
12 R/LFront door switch RH
signalOFFFront door switch
RHON (open) 0V
OFF (closed) Battery voltage
13 GRRear door switch RH
signalOFFRear door switch
RHON (open) 0V
OFF (closed) Battery voltage
22 W/VPower window switch
serial link——
37 B/RKey-in switch detec-
tion signalOFFVehicle key is removed. 0V
Vehicle key is inserted. Battery voltage
38 W/L Ignition power supply ON — Battery voltage
39 W CAN-H — — —
40 R CAN-L — — —
42 GRGlass hatch ajar
switch signalOFFGlass hatch ajar
switchON (open) 0V
OFF (closed) Battery voltage
43 R/BBack door latch (door
ajar switch) signalOFFBack door latch
(door ajar switch)ON (open) 0V
OFF (closed) Battery voltage
47 SBFront door switch LH
signalOFFFront door switch
LHON (open) 0V
OFF (closed) Battery voltage
48 R/YRear door switch LH
signalOFFRear door switch
LHON (open) 0V
OFF (closed) Battery voltage
56 R/GBattery saver output
signalOFF30 minutes after ignition switch is turned
to OFF0V
ON — Battery voltage
57 Y/R Battery power supply OFF — Battery voltage
62 R/W Step lamp signal OFFAny door is open (ON) 0V
All doors are closed (OFF) Battery voltage
63 LInterior room/map
lamp signalOFFEach interior lamp
switch in DOOR
positionAny door
switchON
(open)0V
OFF
(closed)Battery voltage
67 B Ground ON — 0V
70 W/B Battery power supply OFF — Battery voltage
PIIA2344J
INTERIOR ROOM LAMP
LT-145
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
4. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
WORK SUPPORT
Operation Procedure
1. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
2. Touch “WORK SUPPORT” on “SELECT DIAG MODE” screen.
3. Touch “SET I/L D-UNLCK INTCON” on “SELECT WORK ITEM” screen.
4. Touch “START”.
5. Touch “CHANGE SETT”.
6. The setting will be changed and “CUSTOMIZING COMPLETED” will be displayed.
7. Touch “END”.
Display Item List
Reference between “MODE” and “TIME” for “TURN ON/OFF”.
DATA MONITOR
Operation Procedure
1. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
2. Touch “DATA MONITOR” on “SELECT DIAG MODE” screen.
3. Touch either “ALL SIGNALS” or “SELECTION FROM MENU” on “SELECT MONITOR ITEM” screen.
4. Touch “START”.
5. When “SELECTION FROM MENU” is selected, touch items to be monitored. When “ALL SIGNALS” is
selected, all the items will be monitored.
6. Touch “RECORD” while monitoring, then the status of the monitored item can be recorded. To stop
recording, touch “STOP”.
PKIA5226E
Item Description CONSULT-II
SET I/L D-UNLCK INTCONThe 30 seconds operating function of the interior room lamps and the
ignition keyhole illumination can be selected when front door LH is
released (unlocked). ON/OFF
ROOM LAMP ON TIME SETThe time in order to escalate illumination can be adjusted when the
interior room lamps and the ignition keyhole illumination is turned on.MODE 1 - 7
ROOM LAMP OFF TIME SETThe time in order to diminish illumination can be adjusted when the
interior room lamps and the ignition keyhole illumination is turned off.MODE 1 - 7
MODE12345 6 7
Time (sec.) 0.5 1 2 3 4 5 0
ALL SIGNALS Monitors all the signals.
SELECTION FROM MENU Selects and monitors the individual signal.
LT-146
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
Display Item List
ACTIVE TEST
Operation Procedure
1. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
2. Touch “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Touch item to be tested and check operation of the selected item.
4. During the operation check, touching “BACK” or "OFF" deactivates the operation.
Display Item List
Room/Map Lamp Control Does Not OperateEKS007D5
1. CHECK EACH SWITCH
Select “BCM” on CONSULT-II. With “INT LAMP” data monitor, make
sure switches listed in display item list turn ON-OFF linked with
switch operation. Refer to LT-146, "
Display Item List" for switches
and their functions.
OK or NG
OK >> GO TO 2.
NG >> Inspect malfunctioning switch system.
Monitor item Contents
IGN ON SW “ON/OFF” Displays “IGN position (ON)/OFF, ACC position (OFF)” judged from the ignition switch signal.
KEY ON SW “ON/OFF” Displays “Key inserted (ON)/key removed (OFF)” status judged from the key switch signal.
DOOR SW-DR “ON/OFF”Displays status of the front door LH as judged from the front door switch LH signal. (Door is
open: ON/Door is closed: OFF)
DOOR SW-AS “ON/OFF”Displays “Door open (ON)/Door closed (OFF)” status, determined from front door switch RH
signal.
DOOR SW-RR “ON/OFF”Displays “Door open (ON)/Door closed (OFF)” status, determined from rear door switch RH
signal.
DOOR SW-RL “ON/OFF”Displays “Door open (ON)/Door closed (OFF) ” status, determined from rear door switch LH
signal.
BACK DOOR SW “ON/OFF”Displays “Door open (ON)/Door closed (OFF)” status, determined from back door latch (door
ajar switch) signal.
KEY CYL LK-SW “ON/OFF”Displays “Door locked (ON) status, determined from front door lock assembly LH (key cylinder
switch) in front door LH.
KEY CYL UN-SW “ON/OFF”Displays “Door unlocked (OFF) status, determined from front door lock assembly LH (key cylin-
der switch) in front door LH.
CDL LOCK SW “ON/OFF”Displays “Door locked (ON)/Door unlocked (OFF) status, determined from locking detection
switch in front door LH.
CDL UNLOCK SW “ON/OFF”Displays “Door unlocked (OFF)” status, determined from locking detection switch in front door
RH.
KEYLESS LOCK “ON/OFF” Displays “Locked (ON)/Other (OFF)” status, determined from lock signal.
KEYLESS UNLOCK “ON/OFF” Displays “Unlocked (ON)/Other (OFF)” status, determined from unlock signal.
Test item Description
INT LAMP Interior room lamp can be operated by any ON-OFF operations.
IGN ILLUM Ignition keyhole illumination can be operated by ON-OFF operation.
SKIA5930E
LT-150
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
All Interior Room Lamps Do Not OperateEKS007D8
1. CHECK POWER SUPPLY CIRCUIT
1. All interior room lamp switches are OFF.
2. Turn ignition switch ON.
3. Check voltage between BCM harness connector M20 terminal
56 (R/G) and ground.
OK or NG
OK >> Repair harness or connector. To prevent making a short
circuit, be sure to disconnect battery negative cable
after repairing harness, and then reconnect.
NG >> Replace BCM. Refer to BCS-19, "
Removal and Installa-
tion of BCM" .
Ignition Keyhole Illumination Control Does Not OperateEKS007TS
1. CHECK EACH SWITCH
Select “BCM” on CONSULT-II. With “INT LAMP” data monitor, make
sure switches listed in display item list turn ON-OFF linked with
switch operation. Refer to LT-146, "
Display Item List" for switches
and their functions.
OK or NG
OK >> GO TO 2.
NG >> Inspect malfunctioning switch system.
2. ACTIVE TEST
1. Select “BCM” on CONSULT-II. Select “INT LAMP”.
2. Select “IGN ILLUM” active test to make sure lamp operates.
OK or NG
OK >> Replace BCM. Refer to BCS-19, "Removal and Installa-
tion of BCM" .
NG >> GO TO 3.
3. CHECK IGNITION KEYHOLE ILLUMINATION INPUT
1. Check voltage between ignition keyhole illumination harness
connector M150 terminal + (R/G) and ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 6.Battery voltage should exist.
WKIA1486E
SKIA5930E
Keyhole illumination should turn ON.
SKIA3992E
Battery voltage should exist.
WKIA1909E