FRONT WIPER AND WASHER SYSTEM
WW-7
C
D
E
F
G
H
I
J
L
MA
B
WW
Revision: 2004 November 2004 FX35/FX45
FAIL-SAFE FUNCTION
IPDM E/R includes a fail-safe function to prevent malfunction of electrical components controlled by CAN com-
munications in CAN communications occurs.
When fail-safe status is initiated, IPDM E/R remains in steady unit signals are received.
COMBINATION SWITCH READING FUNCTION
Description
BCM reads combination switch (wiper) status, and controls related systems such as head lamps and wip-
ers, according to the results.
BCM reads information of a maximum of 20 switches by combining five output terminals (OUTPUT 1-5)
and five input terminals (INPUT 1-5).
Operation Description
BCM activates transistors of output terminals (OUTPUT 1-5) periodically and, and allows current to flow in
turn.
If any (1 or more) switches are turned ON, circuit of output terminals (OUTPUT 1-5) and input terminals
(INPUT 1-5) becomes active.
At this time, transistors of output terminals (OUTPUT 1-5) are activated to allow current to flow. When volt-
age of input terminals (INPUT 1-5) corresponding to that switch changes, interface in BCM detects volt-
age change, and BCM determines that switch is ON.
SKIA4958E