2002 JEEP GRAND CHEROKEE Control

[x] Cancel search: Control

Page 2111 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual INSTALLATION
INSTALLATION - RECIRCULATION DOOR
VACUUM ACTUATOR
(1) Install the recirculation door vacuum actuator
on the HVAC housing and tighten the mounting
screws to 2.2 N´m (20 in. lbs.).
(2) Eng

Page 2112 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual controlled vehicle accessories during periods of low
engine vacuum such as when the vehicle is climbing
a steep grade, or under other high engine load oper-
ating conditions.
The vacuum reservoir cann

Page 2114 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual BLOWER MOTOR
DESCRIPTION
The blower motor and blower wheel are located in
the passenger side end of the HVAC housing, below
the glove box module. The blower motor controls the
velocity of the air flow

Page 2118 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual HVAC HOUSING
REMOVAL
The HVAC housing assembly must be removed
from the vehicle and the two halves of the housing
separated for service access of the heater core, evap-
orator coil, blend door(s), and

Page 2119 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (14) Remove the HVAC housing from the vehicle,
ensuring that the interior is covered in case of loss of
fluids.
DISASSEMBLY
(1) Remove the HVAC housing from the vehicle.
(Refer to 24 - HEATING & AIR C

Page 2121 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (9) Remove the 10 screws that secure the two
housing halves to each other.
(10) Separate the top half of the HVAC housing
from the bottom half (Fig. 18).
Fig. 17 WIRE HARNESS ELECTRICAL
CONNECTOR(S)
1

Page 2122 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual NOTE: The blend door sub-assembly is attached to
the housing with 2 screws, and may be removed for
service (Fig. 19).
ASSEMBLY
(1) Place the top half of the HVAC housing on the
bottom half. Be certain

Page 2133 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (a) If the refrigerant system fails to reach the
specified vacuum, the system has a leak that must
be corrected. (Refer to 24 - HEATING & AIR CON-
DITIONING/PLUMBING - DIAGNOSIS AND
TESTING - REFRIGER