2002 JEEP GRAND CHEROKEE Wiring harness

[x] Cancel search: Wiring harness

Page 1541 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual CONDITION POSSIBLE CAUSES CORRECTION
GROWLING,
GRATING OR
SCRAPING NOISES1. Drive Plate Broken. 1. Replace.
2. Torque Converter Bolts Hitting
Dust Shield.2. Dust shield bent. Replace or repair.
3. Pla

Page 1644 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (8) Disengage all wiring connectors from the
shifter assembly.
(9) Remove all nuts holding the shifter assembly to
the floor pan (Fig. 239).
(10) Remove the shifter assembly from the vehicle.
INSTALLA

Page 1782 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual INSTALLATION
(1) Place the floor shifter lever in PARK position.
(2) Loosen the adjustment screw on the shift cable.
(3) Verify that the park lock cable adjustment tab
is pulled upward to the unlocked

Page 2080 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual However, evaporator capacity used to reduce the
amount of moisture in the air is not wasted. Wring-
ing some of the moisture out of the air entering the
vehicle adds to the comfort of the passengers.

Page 2084 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (5) Install the new diode in the harness, making
sure current flow is correct. If necessary refer to the
appropriate wiring diagram for current flow.
(6) Solder the connection together using rosin cor

Page 2093 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual gap should be between 0.35 to 0.65 millimeter (0.014
to 0.026 inch). If the proper air gap is not obtained,
add or subtract shims as needed until the desired air
gap is obtained.
(9) Install the compr

Page 2104 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual REMOVAL
(1) Disconnect and isolate the battery negative
cable.
(2) Depress locking tab and unplug the wire har-
ness connector from the blower motor controller.
(3) Depress locking tab and unplug the

Page 2105 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (3) Check for continuity between each of the
blower motor switch input terminals of the resistor
and the resistor output terminal. In each case there
should be continuity. If OK, repair the wire harne