2002 HONDA CIVIC air condition

[x] Cancel search: air condition

Page 787 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
DTC Troubleshooting
DTC 7: An Open in the Air Mix Control Motor
Circuit
1. Test the air mix control motor {see page 2l-341.
ls the air mix control motor OK?
YES-Go to ste

Page 789 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
DTC Troubleshooting.(contd)
DTC 10: An Open or Short in the Mode
Control Motor Circuit
1. Test the mode control motor (see page 21-35).
ls the mode cottol motor OK?
YES G

Page 793 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
DTC Troubleshooting lcontd)
22. Measure the voltage between the No. 3 terminal of
the blower motor relay 4P socket and body ground.
BLOWER MOTOR RELAY 4P SOCKET
21
43
23.

Page 797 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Recirculation Control Motor Circuit Troubleshooting (contd!
10. Turn the ignition swirch OFF.
11. Check for continuity between the following
terminals of heater control p

Page 799 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Condenser Fan Circuit Troubleshooting
NOTE: lf neither the condenser fan nor the radiator fan
work, go to Radiator and Condenser Fans Common
Circuit Troubleshooting (see p

Page 801 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Radiator and Condenser Fans
Common
(contdl
Circuit Troubleshooting
9. Using a Backprobe Set, measure the voltage
between the No. 6 terminal of ECN4 connector B
{24P) and

Page 803 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Compressor Clutch Circuit
Troubleshooting (contdl
16. Check for continuity between the No. lterminal of
the compressor clutch relav 4P socket and the No. l
terminal of th

Page 805 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Air Mix Control Motor Test
1. Disconnect the 5P connector from the air mix
control motor.
2. Connect battery powertothe No. l terminal ofthe
air mix control motor, and gro
Page:   < prev 1-10 ... 9-16 17-24 25-32 33-40 41-48 49-56 next >