2002 CHRYSLER VOYAGER low oil pressure

[x] Cancel search: low oil pressure

Page 1283 of 2399

CHRYSLER VOYAGER 2002  Service Manual CONDITION POSSIBLE CAUSES CORRECTION
OIL CONSUMPTION OR SPARK
PLUGS FOULED1. PCV system malfunction. 1. Check system and repair as
necessary. (Refer to 25 -
EMISSIONS CONTROL/
EVAPORATIVE EMISSIONS/PC

Page 1284 of 2399

CHRYSLER VOYAGER 2002  Service Manual (3) Remove torque converter or clutch housing
cover and inspect rear of block for evidence of oil.
Use a black light to check for the oil leak. If a leak is
present in this area, remove transmission f

Page 1285 of 2399

CHRYSLER VOYAGER 2002  Service Manual Calibrate the tester according to the manufactur-
ers instructions. The shop air source for testing
should maintain 483 kPa (70 psi) minimum, 1,379
kPa (200 psi) maximum, with 552 kPa (80 psi) rec-
o

Page 1286 of 2399

CHRYSLER VOYAGER 2002  Service Manual MOPARtGASKET MAKERis an anaerobic type
gasket material. The material cures in the absence of
air when squeezed between two metallic surfaces. It
will not cure if left in the uncovered tube. The
anaero

Page 1287 of 2399

CHRYSLER VOYAGER 2002  Service Manual STANDARD PROCEDURE - HYDROSTATIC
LOCKED ENGINE
When an engine is suspected to be hydrostatically
locked, regardless of what caused the problem, the
following steps should be used.
CAUTION: DO NOT use

Page 1290 of 2399

CHRYSLER VOYAGER 2002  Service Manual (48) Remove the water pump pulley attaching
bolts and position pulley between pump hub and
housing.
(49) Disconnect the oil pressure switch electrical
connector.
(50) Disconnect wiring harness support

Page 1291 of 2399

CHRYSLER VOYAGER 2002  Service Manual INSTALLATION - ENGINE ASSEMBLY
(1) Position engine and transmission assembly
under vehicle. Slowly lower the vehicle down over the
engine and transmission. It is necessary to move the
engine/transmiss

Page 1296 of 2399

CHRYSLER VOYAGER 2002  Service Manual DESCRIPTION SPECIFICATION
Exhaust (Standard) 6.906±6.924 mm
(0.2718±0.2725 in.)
Valve Stem to Guide Clearance
Intake 0.025±0.065 mm
(0.001±0.0025 in.)
Max. Allowable (Rocking
Method)0.247 mm
(0.01